Critical Power Supplies - Facebook-double Critical Power Supplies - Twitter-double Critical Power Supplies - Linkedin-double Critical Power Supplies - Google-plus-double Freephone 24 Hour: 0800 978 8988 Int: +44 (0)1844 340122
x

Enlogic PDU outlet metered outlet switched en6103 - EN6103

NOTE: Images are for illustrative purposes. If unsure please ask our sales team.

Part Number: EN6103

Call for Pricing: 0800 978 8988

The Enlogic PDU Outlet Metered EN6103 from Critical Power Supplies.

Outlet Metered, Outlet Switched PDU (EN6000 Series)
Comprehensive management solution includes features
of both the EN2000 and EN5000 Series.

PDU Power Metering and Monitoring

" PDU level watt-hour energy metering (kWh)
" PDU level power measurements (W)
" Input Phase level power measurements (V, A, VA, kWh, pf)
" Circuit breaker level current measurements
" High-accuracy, billing-grade metering capabilities
" Embedded memory log to record/view/report historical data
" User customisable alarm thresholds & notifications
Outlet Level Power Metering
" Outlet level watt-hour energy metering (kWh)
" Outlet level power measurements (V,A,VA, W, pf)
" Outlet level information for Green Grid Level 3 PUE Calculations

Environmental & Security Management

" Optional Plug & Play environmental sensors including temperature, humidity, dry contact and water leak
" Rack access monitoring with door contact switch
" User customisable alarm thresholds and notifications

Network Management and Local Display Interface

" Full featured network management and alerting capabilities supporting HTTP, HTTPS, SSH, Telnet, SNMP, Syslog and email
" Strong encryption, passwords, and advanced authorisation options including local permissions, LDAP/S, and active DIrectory
" Daisy Chain up to 4 Rack PDU’s and 24 environmental sensors through a single IP address
" Largest-in-class, high-visibility, oLED display

Features and Benefits

Maximum input – 7.68kVA
Total outlets – 24
Outlet configuration – 24 x C13 10amp sockets
Power and Energy Metering – (V, A, VA, W, kWh, pf) to +/- 1% billing-grade accuracy.
Premium Hydraulic-Magnetic Branch Circuit Breakers are stable at extreme hot aisle temperatures.
Circuit Breaker Status Monitoring – provides active monitoring and alarming of circuit breaker on/off status
Hot Swappable Network Management Card for industry best MTTR.
Environmental Monitoring ready with support for up to 6 plug-and-play sensors.
Daisy chain to manage and monitor up to 4 PDUs and 24 environmental sensors through a single IP address.
Colour-Coded Outlets and Breakers for easy visual identification.
Localised Convenience Outlets options including UK BS1363, German CEE 7/4, and French CEE 7/5.
Adjustable Tool-Less Mounting and universal mounting brackets included for ease of installation.

Dimensions: 1730L x 55W x 50D
Format: Rackmount, Vertical
Downloads
Enlogic PDU Brochure EnLogic_Brochure_UK__Lo-Res___Aug_12_.pdf

Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24x7 on our sales number.


1: Plug and Play (400-3kVA) - Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your warranty up to 3 years, next working day replacement
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 1
Warranty Plus Extends your warranty up to 5 years, next working day replacement
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 2
Intervention, Provides one preventative maintenance visit, planned visit  
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 3
Battery Plus, Provides replacement batteries to site, next working day replacement
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 4
Warranty One Extends your warranty up to 1 year, next working day replacement  
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 5


2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

 

Technical Hotline 24/7
Yes
Yes
Yes
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 6
Preventative Maintenance
Yes
Yes
Yes
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 7
Remote Monitoring 24/7
Yes
Yes
Yes
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 8
Firmware Upgrades
Yes
Yes
Yes
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 9
Emergency Response
Yes
Yes
Yes
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 10
Labour
Yes
Yes
Yes
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 11
Parts
Yes
Yes
Yes
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 12
Monthly Event/Status Report
option
option
option
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 13
Onsite Crash Kit
option
option
option
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 14
Response Time
12 working hours
8 working hours
4 clock hours
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 15


3: 24x7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 16
24x7 flexible status and remote monitoring.      
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 17
Encrypted communication, allowing safe offsite monitoring    
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 18
Alarms and events emailed and SMS texted automatically    
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 19
Firewall Friendly
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 20
Cloud based status overview and multiple sites status on one screen
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 21
Allows First Fix Response to Site
Critical Power Supplies - Enlogic PDU outlet metered outlet switched en6103 image 22

4. IR Thermal Imaging Surveys - Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

.

Let us know what you think of this product

If you have purchased this from us in the past then please take some time to review the product, along with the quality of service you received from us!