The Loadstar range of AC/DC central battery systems from Critical Power Supplies comply with the latest relevant European and British standards. High quality, cost effective units provide secure sources of emergency power for escape and emergency lighting systems in a wide variety of installations. Many years of experience, gained whilst designing and manufacturing systems to customer requirements, have led to the current modular concept based on a basic specification, combined with a choice from five battery types and a number of standard optional extras. This enables the specifier to choose a standard product and select optional extras as required to customise the equipment to meet the project requirements – including maintained or non-maintained versions with 1, 2 or 3 hrs duration, and options for automatic testing capability.

The Loadstar AC/DC central battery system is suitable for any industrial, public or commercial building where centrally supplied emergency lighting is deemed to be the most appropriate solution.

Features and Benefits.

• Low running costs
• Low maintenance
• High specification systems
• Simple operation and reduced complexity
• Fully complies with BS EN50171:2001
• Maintained or non- maintained versions with 1, 2 or 3 hrs duration
• Digital display to clearly indicate system status

Specifications.

Output AC/DC
Power See brochure for full range listing
Battery Chemistry VRLA (5 & 10 year), NiCd, Plante, Flat Plate
Autonomy 1, 2 & 3 hrs (Others available on request)
IP rating IP21 (Others available on request)
Mounting Floor standing
Dimensions See brochure download for full listing
Frequency 50Hz (60Hz optional)

Product Part Numbers.

Selection Table: SLR Range – 10 year design life batteries

System Reference Volts Watts (1 Hour) Amps (1 Hour) Watts (2Hour) Amps (2 Hour) Watts (3Hour) Amps (3 Hour) Cubicle
SLR24/20* 24 250 10.6 152 6.4 110 4.7 †930
SLR24/28* 24 344 14.8 198 8.5 146 6.2 †930
SLR24/40* 24 572 24.7 326 14 243 10.4 †930
SLR24/75* 24 854 37 490 21 364 15.6 †930
SLR24/95* 24 1142 49.4 653 28.1 485 20.8 †930
SLR24/120* 24 1392 60.8 826 35.8 605 26 †931
SLR24/150* 24 1882 81.6 1104 47.6 797 34.1 †931
SLR24/200* 24 2285 98.7 1306 56.2 970 41.6 †931
SLR24/260* 24 3230 138 1695 69 2343 58.4 †932
SLR24/300* 24 3677 156 2123 90.8 1556 65 †932
System Reference Volts Watts (1 Hour) Amps (1 Hour) Watts (2Hour) Amps (2 Hour) Watts (3Hour) Amps (3 Hour) Cubicle
SLR50/20* 50 500 10.6 303 6.4 220 4.7 †931
SLR50/28* 50 687 14.8 396 8.5 292 6.2 †931
SLR50/40* 50 1144 24.7 653 14 486 10.4 †931
SLR50/75* 50 1708 37 979 21 728 15.6 †931
SLR50/95* 50 2285 49.4 1306 28.1 970 20.8 †931
SLR50/120* 50 2734 60.8 1651 35.8 1210 26 †932
SLR50/150* 50 3763 81.6 2208 47.6 1594 34.1 †932
SLR50/200* 50 4570 98.7 2611 56.2 1939 41.6 †932
SLR50/260* 50 6461 138 3389 69 2733 58.4 †934
SLR50/300* 50 7354 156 4246 90.8 3111 65 †934
System Reference Volts Watts (1 Hour) Amps (1 Hour) Watts (2Hour) Amps (2 Hour) Watts (3Hour) Amps (3 Hour) Cubicle
SLR110/20* 110 1126 10.6 682 6.4 496 4.7 †931
SLR110/28* 110 1547 14.8 890 8.5 657 6.2 †931
SLR110/40* 110 2575 24.7 1469 14 1093 10.4 †932
SLR110/75* 110 3845 37 2203 21 1637 15.6 †932
SLR110/95* 110 5141 49.4 2938 28.1 2182 20.8 †932
SLR110/120* 110 6264 60.8 3715 35.8 2722 26 †934
SLR110/150* 110 8467 81.6 4968 47.6 3586 34.1 †934
SLR110/200* 110 10282 98.7 5875 56.2 4363 41.6 †934
SLR110/260* 110 14537 138 7325 69 6150 58.4 †932 + 932
SLR110/300* 110 16546 156 9554 90.8 6950 65 †932 + 934
  • Specify /NM1, /NM2, /NM3, /M1, /M2 or /M3 as appropriate

† See datasheet download for cubical dimensions

Selection Guide: NC Range

System Reference Volts Watts (1 Hour) Amps (1 Hour) Watts (2Hour) Amps (2 Hour) Watts (3Hour) Amps (3 Hour) No of Cells
NC24 Series 24 186 – 3078 7.7 – 126.9 118 – 1979 4.9 – 82.1 83 – 137 3.4 – 57.1 20
NC50 Series 50 389 – 6412 7.7 – 126.9 246 – 4122 4.9 – 82.1 174 – 2872 3.4 – 57.1 42
NC110 Series 110 855 – 14106 7.7 – 126.9 542 – 9070 4.9 – 82.1 383 – 6319 3.4 – 57.1 92

Selection Guide: HP Range

System Reference Volts Watts (1 Hour) Amps (1 Hour) Watts (2Hour) Amps (2 Hour) Watts (3Hour) Amps (3 Hour) No of Cells
HP24 Series 24 236 – 2379 10.0 -102.2 148 – 1474 6.3 – 61.8 111 – 1111 4.6 – 46.2 13
HP50 Series 50 473 – 4758 10.0 – 02.2 296 – 294 6.3 – 61.8 223 – 2215 4.6 – 46.2 26
HP110 Series 110 1001 – 10065 10.0 – 02.2 627 – 6237 6.3 – 61.8 473 – 4686 4.6 – 46.2 55

Selection Guide: HP Range

System Reference Volts Watts (1 Hour) Amps (1 Hour) Watts (2Hour) Amps (2 Hour) Watts (3Hour) Amps (3 Hour) No of Cells
FP24 Series 24 247 – 1482 10.6 – 63.6 164 – 983 6.6 – 39.6 122 – 733 5.0 – 30.0 13
FP50 Series 50 475 – 2850 10.6 – 63.6 315 – 1890 6.6 – 39.6 235 – 1410 5.0 – 30.0 26
FP110 Series 110 1045 – 6270 10.6 – 63.6 693 – 4158 6.6 – 39.6 517 – 3102 5.0 – 30.0 55
Part Number Loadstar AC/DC Central Battery System
Downloads
Product Datasheet loadstar_acdc_systems_datasheet.pdf
Technical Information acdc_cbu_loadstar_manual.pdf

Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24x7 on our sales number.

1: Plug and Play (400-3kVA) - Extended Warranty Contracts from 1 to 5 years from £9.99 per month ex VAT

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your warranty up to 3 years, next working day replacement
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 1
Warranty Plus Extends your warranty up to 5 years, next working day replacement
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 2
Intervention, Provides one preventative maintenance visit, planned visit  
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 3
Battery Plus, Provides replacement batteries to site, next working day replacement
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 4
Warranty One Extends your warranty up to 1 year, next working day replacement  
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 5


2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

 

Technical Hotline 24/7
Yes
Yes
Yes
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 6
Preventative Maintenance
Yes
Yes
Yes
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 7
Remote Monitoring 24/7
Yes
Yes
Yes
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 8
Firmware Upgrades
Yes
Yes
Yes
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 9
Emergency Response
Yes
Yes
Yes
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 10
Labour
Yes
Yes
Yes
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 11
Parts
Yes
Yes
Yes
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 12
Monthly Event/Status Report
option
option
option
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 13
Onsite Crash Kit
option
option
option
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 14
Response Time
12 working hours
8 working hours
4 clock hours
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 15

 

3: 24x7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 16
24x7 flexible status and remote monitoring.      
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 17
Encrypted communication, allowing safe offsite monitoring    
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 18
Alarms and events emailed and SMS texted automatically    
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 19
Firewall Friendly
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 20
Cloud based status overview and multiple sites status on one screen
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 21
Allows First Fix Response to Site
Critical Power Supplies - Eaton Loadstar AC/DC Central Battery System image 22


>

4. IR Thermal Imaging Surveys - Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

.

Let us know what you think of this product

If you have purchased this from us in the past then please take some time to review the product, along with the quality of service you received from us!

How can we help?