Critical Power Supplies - Facebook-double Critical Power Supplies - Twitter-double Critical Power Supplies - Linkedin-double Critical Power Supplies - Google-plus-double Freephone 24 Hour: 0800 978 8988 Int: +44 (0)1844 340122
x

Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) - MHE 200 NBP

NOTE: Images are for illustrative purposes. If unsure please ask our sales team.

Part Number: MHE 200 NBP

Call for Pricing: 0800 978 8988

MHE 200 NBP Overview

The Master HE uninterruptible  power supply series combines exceptional reliability with operational  efficiency of up to 95.5%, reducing operators’ power consumption and  energy waste. This unit doesnt contain a static bypass and is a special order unit.

Available in 10 power ratings from 100-800 kVA, this  three-phase online UPS uses advanced double conversion technology to  protect mission-critical and industrial loads in settings such as data  centres, security systems, electro-medical devices, and telecoms  networks.
Delivering unity power factor, it incorporates an output isolation  transformer to enhance load protection, while its high-performing  components can withstand the stresses of temperatures up to 40oC.

Features

  • Up to 8 Master MHE can be installed in parallel for extra capacity or redundancy.
  • Delivers quality power in mission-critical environments like data  centres, telecoms networks, security systems, electro-medical devices,  and industrial applications.
  • Automatically selects the most efficient operating mode based on mains input quality.
  • Operating efficiency up to 98.5% in Smart Active operating mode

Other Configurations

ModelFeatures
MHE 200Unity power factor 200kVA UPS
MHT 200
Standard Master Plus HT 200kVA UPS with a 0.9 Power Factor.
MHE 200 NBP
No static bypass switch
MHT 200 NBP
No static bypass switch
INPUT
Rated power 200000 VA
Voltage 400 Vac three-phase
Voltage tolerance + 20% - 25%
Frequency 50/60 Hz with autorange
Frequency tolerance 45/65 Hz
Power factor 0,99
Input current 281 A
Current distorsion <3%
Soft start 0-100% in 10
BY PASS
Rated voltage 400 Vac three-phase selectable 380 and 415
Voltage tolerance ± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency 50/60 Hz (autorange)
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Rated current 281 A
Number phases 3
Back-feed protection yes
Overload capacity Inx10ms 14
OUTPUT and INVERTER OUTPUT
Rated power 200000 VA
Active power 200000 W
Number phases 3 + N
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Dynamic stability ± 5% in 5 ms
Frequency same as the input (autorange)
Voltage distortion with distorcing load <3%
Voltage distortion with linear load <1%
Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5% from front panel) with mains supply present
Overload 125% 150% 200% of the rated current for 10' / 1' / 7
RECTIFIER OUTPUT
Ripple <1%
BATTERIES
Type Maintenance-free sealed lead-acid
Maximum recharge current 0.2xC10
ENVIRONMENTAL
Altitude max 1000 m
Color Dark grey RAL 7035
Remote controls EPO and bypass
Safety compliance EN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU
EMC conformance EN 62040-2 and Directive 2014/30/EU
Protection rating IP20
Line-Interactive/Smart Active efficiency up to 99,4%
Noise (at 1 m) 63 dBA at 1 m
Remote signals voltage free contacts (mains power failure, UPS on bypass, end of discharge pre-alarm, output 12Vdc 80mA)
Operating temperature 0 ÷ 40 °C
Relative humidity 95% no condensing
DATA
Weight 910 kg
Dimensions (h w d) 1900x1000x850 mm
Downloads
Product Datasheet MasterHPHE-ProductDatasheet.pdf

Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24x7 on our sales number.


1: Plug and Play (400-3kVA) - Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your warranty up to 3 years, next working day replacement
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 1
Warranty Plus Extends your warranty up to 5 years, next working day replacement
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 2
Intervention, Provides one preventative maintenance visit, planned visit  
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 3
Battery Plus, Provides replacement batteries to site, next working day replacement
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 4
Warranty One Extends your warranty up to 1 year, next working day replacement  
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 5


2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

 

Technical Hotline 24/7
Yes
Yes
Yes
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 6
Preventative Maintenance
Yes
Yes
Yes
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 7
Remote Monitoring 24/7
Yes
Yes
Yes
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 8
Firmware Upgrades
Yes
Yes
Yes
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 9
Emergency Response
Yes
Yes
Yes
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 10
Labour
Yes
Yes
Yes
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 11
Parts
Yes
Yes
Yes
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 12
Monthly Event/Status Report
option
option
option
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 13
Onsite Crash Kit
option
option
option
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 14
Response Time
12 working hours
8 working hours
4 clock hours
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 15


3: 24x7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 16
24x7 flexible status and remote monitoring.      
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 17
Encrypted communication, allowing safe offsite monitoring    
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 18
Alarms and events emailed and SMS texted automatically    
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 19
Firewall Friendly
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 20
Cloud based status overview and multiple sites status on one screen
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 21
Allows First Fix Response to Site
Critical Power Supplies - Riello Master Plus MHE 200kVA Online 400V (UPS) (No Internal Batteries) (No Static Bypass) image 22

4. IR Thermal Imaging Surveys - Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

.

Let us know what you think of this product