Critical Power Supplies - Facebook-double Critical Power Supplies - Twitter-double Critical Power Supplies - Linkedin-double Critical Power Supplies - Google-plus-double Freephone 24 Hour: 0800 978 8988 Int: +44 (0)1844 340122
x

Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u - PDU3XVN6G20

Part Number: PDU3XVN6G20

Product (ex VAT):
£718.18
Product (inc VAT):
£861.81
Call to check stock
Call for information

Tripp Lite 3 phase Monitored PDU / Power Distribution Unit offers rEAL-time remote monitoring of voltage and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip.

- Monitored 11.5kW 3-Phase 360/380/400/415V input 200/220/230/240V output PDU
- Reports voltage & load per-phase via ethernet interface
- 1% billing-grade accuracy; Digital display reports detailed status and loading information
- 70in / 1778mm 0U vertical format; Toolless button-mount installation

- 42 C13 & 6 C19 single phase outlets; Plug-lock cable retention inserts keep power cables secure
- IEC309 16/20A Red (3P+N+E) 3 phase input; 6 ft. / 1.8m line cord
- TAA Compliant

- 11.5kW Monitored 360/380/400/415V input 200/220/230/240V output PDU with built-in web/network interface
- IEC309 16/20A Red (3P+N+E) 360-415V 3 phase input with 6-ft. / 1.8m line cord
- 0U, 70 inch / 178cm vertical form factor
- 48 200-240V outlets (42 C13, 6 C19) in 3 single phase load banks
- Lighted display with scroll-button reports power consumption in amps for all 3 loading banks, IP-address self-identification and 180 degree display rotation for overhead or raised floor power feeds
- Built-in SNMP/ethernet interface reports voltage and PDU loading per-phase via network or secure web browser interface with options for user specified alarm and notification thresholds
- Supports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
- DHCP/Manual configuration support
- 10/100 Mbps auto-sensing allows optimal communicationtion with 10/100 Base-T networks
- REAL-time clock backup maintains the time of day and date even if the PDU is unpowered
- Tiered access privileges allow an administrator and a guest to login via web browser for monitoring
- Alert notifications via email or SNMP traps offer immediate event notification
- Firmware upgrade ability supports future product enhancements
- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
- Fully compatible with FREE PowerAlert Network Management System / NMS Software
- Included set of plug-lock inserts keep C14 & C20 power cords solidly connected to PDU outlets
- Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)

Design
On/off switchYes
PDU typesMonitored
MountingVertical
Product colourBlack
Rack capacity0U
Housing materialMetal
Ports & interfaces
Master AC outlets quantity42
Slave AC outlets quantity6
AC outlets quantity48 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power plugIEC309
Ethernet LAN (RJ-45) ports2
Features
Cable length1.8 m
LED indicatorsYes
Management features
MonitoringCurrent
Ergonomics
Cable length1.8 m
LED indicatorsYes
Power
Maximum power11500 W
Nominal input voltage360 - 415 V
Nominal output voltage200-240 V
Maximum current16 A
AC input frequency50 - 60 Hz
Weight & dimensions
Dimensions (WxDxH)55.1 x 73 x 1778 mm
Weight6.12 kg
Size (imperial)177.8 cm (70")
Width55.1 mm
Depth72.6 mm
Height1778 mm
Package width245.1 mm
Package depth1927.1 mm
Package height175 mm
Package weight9.19 kg
Package dimensions (WxDxH)246 x 1928 x 175 mm
Packaging data
Package width245.1 mm
Package depth1927.1 mm
Package height175 mm
Package weight9.19 kg
Package dimensions (WxDxH)246 x 1928 x 175 mm
Operational conditions
Operating temperature (T-T)0 - 50 °C
Storage temperature (T-T)-15 - 60 °C
Operating relative humidity (H-H)5 - 95%
Operating temperature (T-T)32 - 122 °F
Operating altitude0 - 3000 m
Technical details
Sustainability certificatesRoHS
Logistics data
Master (outer) case width24.5 cm
Master (outer) case length192.7 cm
Master (outer) case height17.5 cm
Master (outer) case gross weight9.19 kg
Products per master (outer) case1 pc(s)
Country of originTaiwan

Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24x7 on our sales number.


1: Plug and Play (400-3kVA) - Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your warranty up to 3 years, next working day replacement
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 1
Warranty Plus Extends your warranty up to 5 years, next working day replacement
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 2
Intervention, Provides one preventative maintenance visit, planned visit  
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 3
Battery Plus, Provides replacement batteries to site, next working day replacement
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 4
Warranty One Extends your warranty up to 1 year, next working day replacement  
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 5


2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

 

Technical Hotline 24/7
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 6
Preventative Maintenance
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 7
Remote Monitoring 24/7
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 8
Firmware Upgrades
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 9
Emergency Response
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 10
Labour
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 11
Parts
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 12
Monthly Event/Status Report
option
option
option
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 13
Onsite Crash Kit
option
option
option
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 14
Response Time
12 working hours
8 working hours
4 clock hours
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 15


3: 24x7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 16
24x7 flexible status and remote monitoring.      
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 17
Encrypted communication, allowing safe offsite monitoring    
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 18
Alarms and events emailed and SMS texted automatically    
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 19
Firewall Friendly
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 20
Cloud based status overview and multiple sites status on one screen
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 21
Allows First Fix Response to Site
Critical Power Supplies - Tripp lite 11.5kw 3-phase monitored PDU, 200/220/230/240v outlets (42 c13, 6 c19), iec309 16/20a red, 360-415v input, 0u image 22

4. IR Thermal Imaging Surveys - Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

.

Let us know what you think of this product

If you have purchased this from us in the past then please take some time to review the product, along with the quality of service you received from us!