Critical Power Supplies - Facebook-double Critical Power Supplies - Twitter-double Critical Power Supplies - Linkedin-double Critical Power Supplies - Google-plus-double Freephone 24 Hour: 0800 978 8988 Int: +44 (0)1844 340122
x

Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount - PDUMH30HVNET

NOTE: Images are for illustrative purposes. If unsure please ask our sales team.

Part Number: PDUMH30HVNET

Product (ex VAT):
£652.72
Product (inc VAT):
£783.26
Call to check stock
Call for information

Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in rEAL-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorised hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.
- 30A 208/240V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 24A continuous)
- Attached L6-30P 208/240V single phase input, 12 ft. / 3.6m input cord
- 2U horizontal rack mount form factor
- 16 switched c13 outlets
- Supports power-on, power-off or reboot of each outlet on a rEAL-time or programmable basis
- Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets
- Network interface provides PDU control and data regarding input voltage and total output load level in amps
- Digital display continuously reports output load in amps in 3 segments (load bank 1, load bank 2, total)
- Supports user-specified alarm notification thresholds
- In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
- DHCP/Manual configuration support
- 10/100 Mbps auto-sensing
- REAL-time clock backup maintains the time of day and date even if the PDU is unpowered
- Tiered access privileges allow an administrator and a guest to login via web browser
- Alert notifications via email or SNMP traps offer immediate event notification
- Firmware upgrade ability supports future product enhancements
- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
- Fully compatible with FREE PowerAlert Network Management System / NMS Software
- 2U horizontal rack installation supported in 2 or 4 post racks with included mounting brackets
- Mounting brackets support wall-mount and under-counter installation in many applications
- Included cord retention brackets
- TAA Compliant Version AVAilable – Order Tripp Lite PDUMH30HVNETAA

Design
PDU typesSwitched
MountingHorizontal
Product colourBlack
CertificationUL 60950-1, Class A, NOM
Rack capacity2U
Housing materialMetal
Ports & interfaces
AC outlets quantity16 AC outlet(s)
AC outlet typesC13 coupler
Power plugNEMA L6-30P
Features
Cable length3.6 m
CertificationUL 60950-1, Class A, NOM
Ergonomics
Cable length3.6 m
Power
Nominal input voltage200-240 V
Nominal output voltage200-240 V
Maximum current30 A
AC input frequency50 - 60 Hz
Weight & dimensions
Dimensions (WxDxH)445 x 317.5 x 89 mm
Weight6.21 kg
Width444.5 mm
Depth317.5 mm
Height88.9 mm
Package width424.2 mm
Package depth497.8 mm
Package height198.1 mm
Package weight7.71 kg
Packaging data
Package width424.2 mm
Package depth497.8 mm
Package height198.1 mm
Package weight7.71 kg
Operational conditions
Storage temperature (T-T)-15 - 50 °C
Operating altitude0 - 3000 m
Technical details
Sustainability certificatesRoHS
Logistics data
Products per master (outer) case1 pc(s)
Country of originTaiwan

Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24x7 on our sales number.


1: Plug and Play (400-3kVA) - Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your warranty up to 3 years, next working day replacement
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 1
Warranty Plus Extends your warranty up to 5 years, next working day replacement
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 2
Intervention, Provides one preventative maintenance visit, planned visit  
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 3
Battery Plus, Provides replacement batteries to site, next working day replacement
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 4
Warranty One Extends your warranty up to 1 year, next working day replacement  
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 5


2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

 

Technical Hotline 24/7
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 6
Preventative Maintenance
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 7
Remote Monitoring 24/7
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 8
Firmware Upgrades
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 9
Emergency Response
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 10
Labour
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 11
Parts
Yes
Yes
Yes
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 12
Monthly Event/Status Report
option
option
option
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 13
Onsite Crash Kit
option
option
option
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 14
Response Time
12 working hours
8 working hours
4 clock hours
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 15


3: 24x7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 16
24x7 flexible status and remote monitoring.      
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 17
Encrypted communication, allowing safe offsite monitoring    
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 18
Alarms and events emailed and SMS texted automatically    
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 19
Firewall Friendly
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 20
Cloud based status overview and multiple sites status on one screen
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 21
Allows First Fix Response to Site
Critical Power Supplies - Tripp lite 5.8kw single-phase switched PDU, 208/240v outlets (16 c13), l6-30p input, 3.66 m (12-ft.) cord, 2u rack-mount image 22

4. IR Thermal Imaging Surveys - Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

.