Critical Power Supplies - Facebook-double Critical Power Supplies - Twitter-double Critical Power Supplies - Linkedin-double Critical Power Supplies - Google-plus-double Freephone 24 Hour: 0800 978 8988 Int: +44 (0)1844 340122
x

Riello Sentinel Dual 10kVA Online (UPS) - SDU 10000 TM

NOTE: Images are for illustrative purposes. If unsure please ask our sales team.

Part Number: SDU 10000 TM

Product (ex VAT):
£2,176.46
Product (inc VAT):
£2,611.75
2 IN STOCK:

SDU 10000 TM Overview

The Sentinel Dual 10000 TM is an excellent choice for any IT equipment or critical infrastructure built with superior power protection. Your mind can rest easy, knowing you won't lose any data or machine downtime. The Sentinel Dual 10000 TM is built to have a three-phase input and a single phase output allowing flexibility with your power distribution.

The Sentinel Dual range is built with the double conversion online to ensure protection from; power outages, power sags, overvoltages, power surges, brownouts, electrical lines, frequency variation, switching transients and harmonic distortion.

The Sentinel Dual 10000 TM is rated for 10000 Watts to power your storage servers, networking equipment, monitoring devices and more. The Sentinel Dual range also can be mounted in a tower or rack format with ease, and rotating display means you can easily monitor your UPS in either orientation.

Battery Expansion Options

Model
External Battery Dimensions
Runtime @ 100% Load
View Online
1x BB SDU 240-A3
131(3U) x 640 x 455mm (19")
(H x D x W)
7 Minutes
Click Here
2x BB SDU 240-A3
11 Minutes
Click Here

Package includes

  • Manufactured battery pack to UPS cable standard length.
  • USB Cable.
  • Support feet and extensions.
  • Handles for rack installations and screws.
  • Battery expansion plug (ER version only).
  • Manual, Quick start guide and download card.

Features and Benefits

  • Parallelable up to 2 unit.
  • Simplified installation.
  • Operating mode selection Online, Eco, Smart active, Emergency, Frequency Converter.
  • High battery reliability.
  • High Efficiency up to 95% on line mode, 98% eco mode.
  • Low noise level <48dba.
  • Filtered, stabilised and reliable voltage (double conversion on-line technology (VFI compliant with EN62040-3).
  • Battery optimisation.
  • Energy Share on models with IEC output Sockets.
  • Advanced communications.
INPUT
Dual Input no
Rated power 10000 VA
Voltage 380-400-415 Vac (3W+N+PE) 220-230-240 Vac (1W+N+PE)
Voltage tolerance 242 Vac < Vin < 478 Vac @50% LOAD / 318 Vac < Vin < 478 Vac @ 100% LOAD (3W+N+PE) 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD (1W+N+PE)
Frequency 50/60 Hz ± 5 Hz
Frequency tolerance 50 Hz ± 20% / 60 Hz ± 20%
Power factor >0.98
Current distorsion ≤5%
BY PASS
Voltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)
Frequency tolerance Selected frequency ± 5% (user configurable)
Number phases 1
OUTPUT and INVERTER OUTPUT
Rated power 10000 VA
Active power 10000 W
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Frequency 50/60 Hz selectable
Voltage distortion with distorcing load <3%
Voltage distortion with linear load <1%
Inverter efficiency at rated load 95% %
OVERLOAD TIMES
100% < Load < 110% activates the bypass after 10 min Continues to work on by-pass
110% < Load < 133% activates the bypass after 1 min shut down after 1 hour
133% < Load < 150% activates the bypass after 5 s shut down after 10 min
Load > 150% activates the bypass instantaneously shutdown after 3 s (load > 150%) shutdown after 2 s (load > 200%)
BATTERIES
Type VRLA AGM lead, maintenance-free
Typical recharge time 4÷6 h
OPTIONS
Parallel kit (to order with the UPS) Yes
ENVIRONMENTAL
Altitude max 1000 m at nominal power (-1% power for every 100 m above 1000 m) 4000 m maximum
Color Black RAL 9005
Communication USB / DB9 with RS232 and contacts / Slot for communication interface
Safety compliance EN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU
EMC conformance EN 62040-2 and Directive 2014/30/EU
Accessories provided USB cable; handles kit
Protection rating IP20
Surge capability 1 VDR x 300 Joules
Marks CE
Protections Overload - short-circuit - overvoltage - undervoltage - temperature - low battery
AC/AC efficiency 95%
Line-Interactive/Smart Active efficiency 98%
Noise (at 1 m) <48 dBA
Operating temperature 0 ÷ 40 °C
Relative humidity 5 - 95% no condensing
Output sockets Terminal block + 2 IEC 320 C13 + 3 IEC 320 C19
DATA
Weight 20+62 kg
Dimensions (h w d) 2 x (448 x 131 x 640) tower - 2 x (3U x 19” x 640) rack mm
Input phases 3/1
Output phases 1

Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24x7 on our sales number.


1: Plug and Play (400-3kVA) - Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your warranty up to 3 years, next working day replacement
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 1
Warranty Plus Extends your warranty up to 5 years, next working day replacement
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 2
Intervention, Provides one preventative maintenance visit, planned visit  
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 3
Battery Plus, Provides replacement batteries to site, next working day replacement
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 4
Warranty One Extends your warranty up to 1 year, next working day replacement  
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 5


2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

 

Technical Hotline 24/7
Yes
Yes
Yes
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 6
Preventative Maintenance
Yes
Yes
Yes
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 7
Remote Monitoring 24/7
Yes
Yes
Yes
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 8
Firmware Upgrades
Yes
Yes
Yes
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 9
Emergency Response
Yes
Yes
Yes
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 10
Labour
Yes
Yes
Yes
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 11
Parts
Yes
Yes
Yes
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 12
Monthly Event/Status Report
option
option
option
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 13
Onsite Crash Kit
option
option
option
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 14
Response Time
12 working hours
8 working hours
4 clock hours
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 15


3: 24x7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 16
24x7 flexible status and remote monitoring.      
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 17
Encrypted communication, allowing safe offsite monitoring    
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 18
Alarms and events emailed and SMS texted automatically    
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 19
Firewall Friendly
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 20
Cloud based status overview and multiple sites status on one screen
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 21
Allows First Fix Response to Site
Critical Power Supplies - Riello Sentinel Dual 10kVA Online (UPS) image 22

4. IR Thermal Imaging Surveys - Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

.

Riello UPS Product Overview

Let us know what you think of this product

If you have purchased this from us in the past then please take some time to review the product, along with the quality of service you received from us!