APC Network Management Card Compatibility

Network Management Card Model(s)UPS ModelNote(s)
  • AP9617, AP9618, AP9619
  • Single and Three Phase Smart-UPS with the following model prefixes: 
    • - SU
    • - SUA
    • - SUM
    • - SURT
    • - SURTA
    • - SURTD
    • - SUVT*
  • Matrix UPS with UPS firmware versions Y or Z 
    • - MX3000
    • - MX5000
  • Single phase Symmetra models: 
    • - Symmetra Power Array
    • - Symmetra RM 6K/12K
    • - Symmetra LX
  • Three phase Symmetra models: 
    • - 20kW Symmetra PX All-In-One
    • - 40kW Symmetra PX
    • - 80kW Symmetra PX
    • - 100kW Symmetra PX2**
    • - 160kW Symmetra PX2**
  • Silcon
  • *Note: SUVT model UPSs with v7.X.X firmware should use NMC2 to take advantage of all UPS firmware enhancements.
  
  • **Note: This  add-on option is only able to monitor the UPS, and not any power  distribution. The embedded NMC within the UPS must be used to monitor  any power distribution.
  • AP9630/30CH, AP9631/31CH
  • Single and Three Phase Smart-UPS with the following model prefixes: 
    • - SU
    • - SUA
    • - SUM
    • - SURT
    • - SURTA
    • - SURTD
    • - SUVT & MGE Galaxy 3500
    • - SMT
    • - SMX
    • - SRT
  • Matrix UPS with UPS firmware versions Y or Z 
    • - MX3000
    • - MX5000
  • Single phase Symmetra models: 
    • - Symmetra Power Array
    • - Symmetra RM
    • - Symmetra LX
  • Three phase Symmetra models: 
    • - 48kW Symmetra PX2 All-In-One*
    • - 20kW Symmetra PX
    • - 40kW Symmetra PX
    • - 80kW Symmetra PX
    • - 100kW Symmetra PX2*
    • - 160kW Symmetra PX2*
  • SMX/SMT require sumx APP v5.0.3 or higher.
  
  • SRT models require sumx APP v6.0.7, or v6.2.0 or higher
  
  • *Note: This  add-on option is only able to monitor the UPS, and not any power  distribution. The embedded NMC within the UPS must be used to monitor  any power distribution.
  • AP9630/30CH, AP9631/31CH, AP9635/35CH
  • Three Phase Galaxy UPS units 
    • - Galaxy 300/7000*
    • - Galaxy VM
  • *Ships with AP9630  pre-installed in units manufactured post 2012. Older G7000 models  require a special upgrade kit pre-2012 manufacture date.
  • AP9635/35CH
  • 3 Phase UPS models including: 
    • - Symmetra PX 250/500
    • - SUVT/G500*
    • - Symmetra PX 20/40/80
    • - Symmetra PX2 48kW All-in-One*
    • - Symmetra PX2 100/160 kW*
  • Single Phase UPS models including: 
    • - SmartUPS*
    • - Symmetra*
  • *With AOS 6.4+ only, modem features only supported on MGE Galaxy units
  • AP9640, AP9641
  • Single and Three Phase Smart-UPS with the following model prefixes: 
    • - SUA*
    • - SUM
    • - SURT
    • - SURTA
    • - SURTD
    • - SUVT & MGE Galaxy 3500
    • - SMT
    • - SMX
    • - SRT
  • *Note: SUA devices manufactured after 2008, except SUA750RM1U
  • AP9644
  • Three Phase Galaxy UPS units: 
    • - Galaxy VS*
  • *Ships with AP9644 pre-installed. 
  • G5K9635CH
  • MGE Galaxy 5000
  • Kit includes all necessary parts to install an AP9635 for all G5000 UPS serial numbers and firmwares.
  • G9K9635CH
  • MGE Galaxy 9000
  • Kit includes all necessary parts to install an AP9635 for all G9000 UPS serial numbers and firmwares.
  • AP9606
  • Older UPS models including: 
    • Smart-UPS with the following model prefix: 
      • - SU
      • - SUA
    • - Symmetra Power Array
    • - Symmetra RM 6K/12K
    • - Matrix UPS with UPS firmwares Y or Z 
      •      - MX3000
      •      - MX5000
    • - 40kW Symmetra PX
    • - 80kW Symmetra PX
  • Silcon
 
  • 0J-0N-9581GVM
  • Galaxy VM
  • Spare part for Galaxy VM Display/Embedded Network Management Card inside
  • 0G-9354
  • W0G-9354 (spare part)
  • 0G-9354A
  • 0J-0G-9354A (spare part)
  • Three phase Symmetra (PX2) models: 
    • - 48kW Symmetra PX All-In-One
    • - 100kW Symmetra PX
    • - 160kW Symmetra PX
  • UPS brain with embedded Network Management Card.
  • "A" SKU's are built on NMC2 architecture

Note: Certain features are limited by application.