Critical Power Supplies - Facebook-double Critical Power Supplies - Twitter-double Critical Power Supplies - Linkedin-double Critical Power Supplies - Google-plus-double 24 Hour: 0800 978 8988 Int: +44 (0)1844 340122
x

Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups)

Product (ex VAT):
£8,700.06
Product (inc VAT):
£10,440.07
ETA 2 - 5 DAYS
Call for information

The Vertiv APS UPS provides mission-critical availability ensuring your critical IT functions “ and your business “ will be available and running as expected through power disruptions, fluctuations and outages.

The Vertiv APS UPS adapts efficiently and effectively as the needs of your users and core business power requirements change. The UPS offers capacity on demand with FlexPower core modules “ allowing you to change capacity in 5kVA/4.5kW increments up to 20kVA.

- True on-line double conversion UPS
- Transformer-free and transformer-based models
- User installable, hot-swappable capacity and battery modules
- Internal redundancy capability (N+2/20kVA)

Low Total Cost of Ownership

- Industry-leading efficiency: 92% for transformer-free systems and up to 89.9% for transformer based systems.
- Scalability that allows you to cost-effectively add power capacity or battery modules as needed.
- Modular batteries, controls and power components to help reduce maintenance costs with user replacement.
- Two year hassle-free factory warranty program for repair or replacement of your Vertiv APS UPS.
- Module-level redundancy eliminates the expense of purchasing and planning for additional cabinets.
- Reduced installation time and cost because units are shipped pre-configured and factory tested, no need for on-site assembly.
- Everything you need for efficiency and availability in one box: power modules, batteries, maintenance bypass, and distribution in a single, small-footprint cabinet.
- Integral battery monitoring with temperature compensated charging to prolong battery life and help reduce replacement costs.

Reliability and Serviceability

- Internal redundancy capability (N+2/20kVA) enhances reliability and provides multiple layers of power protection.
- No single point of failure – Full redundant design allows the critical load to run on conditioned power if there is a failure of any component in the system.
- Configurable design allows you to customize the Vertiv APS UPS for your desired level of capacity and redundancy.
- Fault-tolerant design, enables the power, battery and control modules to take themselves offline if there is a problem, without sacrificing overall system integrity.
- Superior overload capabilities, able to provide conditioned power to temporary overloads without transfers to/from bypass power.
- Internal wrap-around maintenance bypass and frame-level bypass with independent controls in separate assembly provide higher reliability and availability.

Flexibility

- Capacity on demand with FlexPowerâ„¢ core modules that allow you to change capacity as needed in 5 kVA/4.5 kW increments – without powering down.
- More real kW – 0.9 power factor provides more real power to support the I.T. load than other solutions in this size range.
- Isolated and non-isolated models to provide the right solution for your power protection needs.
- Integrated distribution PODs allow selection of a variety of distribution options to meet application requirements.
- Trellisâ„¢ platform connectivity, so the Vertiv APS can easily be integrated with this robust, real-time data center optimization solution.
- Three Vertiv Intellislot ports allow integration and communication with a variety of infrastructure management solutions, leading to better power optimization and visibility.
- Optional matching external battery cabinets provide longer battery run times to protect against sustained power issues.
- Installation Flexibility “ use on raised floors, traditional flooring, or in rack enclosures.
- Large input voltage window, which minimizes transfer to battery and increases battery life; low line transfer can range down to 110v.
- Wide range of use, with the ability to be installed on raised floors, traditional flooring, or in rack enclosures

Ideally Suited For

- Small-to-medium-sized data centers
- Network closets
- VoIP

Power
Output voltage regulation±3
Input operation voltage (min)200 V
Input operation voltage (max)415 V
Output operation voltage (min)200 V
Output operation voltage (max)240 V
Power supply input frequency40 - 70
Power factor0.9
Output power capacity15000 VA
Battery
Number of batteries supported16
Number of battery cells6
Battery recharge time5 h
Typical backup time at full load5 min
Hot-swap batteryYes
Design
Form factorTower
Colour of productBlack
DisplayLCD
Performance
LED indicatorsYes
Technical details
Output frequency50/60 Hz
Operational conditions
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95%
Operating altitude0 - 3000 m
Certificates
SafetyIEC/EN/AS 62040-1:2008, UL 1778 4th Ed and CSA 22.2 No. 107.1
Energy Star certifiedYes
CertificationIEC/EN/AS 62040-2 Cat 2, CISPR22 Class A, FCC Part 15 Class A
IEC/EN/AS 61000-4-2, 3, 4, 5, 6
WEEE, REACH
RoHS complianceYes
Weight & dimensions
Weight317.5 kg
Width440 mm
Package weight335.7 kg
Height970 mm
Depth850 mm
Power
Output voltage regulation±3
Input operation voltage (min)200 V
Input operation voltage (max)415 V
Output operation voltage (min)200 V
Output operation voltage (max)240 V
Power supply input frequency40 - 70
Power factor0.9
Output power capacity15000 VA
Battery
Number of batteries supported16
Number of battery cells6
Battery recharge time5 h
Typical backup time at full load5 min
Hot-swap batteryYes
Design
Form factorTower
Colour of productBlack
DisplayLCD
Performance
LED indicatorsYes
Technical details
Output frequency50/60 Hz
Operational conditions
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)0 - 95%
Operating altitude0 - 3000 m
Certificates
SafetyIEC/EN/AS 62040-1:2008, UL 1778 4th Ed and CSA 22.2 No. 107.1
Energy Star certifiedYes
CertificationIEC/EN/AS 62040-2 Cat 2, CISPR22 Class A, FCC Part 15 Class A
IEC/EN/AS 61000-4-2, 3, 4, 5, 6
WEEE, REACH
RoHS complianceYes
Weight & dimensions
Weight317.5 kg
Width440 mm
Package weight335.7 kg
Height970 mm
Depth850 mm
Part Number AS2C0NCRMNNX000

Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24x7 on our sales number.

1: Plug and Play (400-3kVA) - Extended Warranty Contracts from 1 to 5 years from £9.99 per month ex VAT

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your warranty up to 3 years, next working day replacement
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 1
Warranty Plus Extends your warranty up to 5 years, next working day replacement
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 2
Intervention, Provides one preventative maintenance visit, planned visit  
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 3
Battery Plus, Provides replacement batteries to site, next working day replacement
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 4
Warranty One Extends your warranty up to 1 year, next working day replacement  
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 5


2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

 

Technical Hotline 24/7
Yes
Yes
Yes
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 6
Preventative Maintenance
Yes
Yes
Yes
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 7
Remote Monitoring 24/7
Yes
Yes
Yes
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 8
Firmware Upgrades
Yes
Yes
Yes
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 9
Emergency Response
Yes
Yes
Yes
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 10
Labour
Yes
Yes
Yes
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 11
Parts
Yes
Yes
Yes
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 12
Monthly Event/Status Report
option
option
option
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 13
Onsite Crash Kit
option
option
option
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 14
Response Time
12 working hours
8 working hours
4 clock hours
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 15

 

3: 24x7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 16
24x7 flexible status and remote monitoring.      
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 17
Encrypted communication, allowing safe offsite monitoring    
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 18
Alarms and events emailed and SMS texted automatically    
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 19
Firewall Friendly
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 20
Cloud based status overview and multiple sites status on one screen
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 21
Allows First Fix Response to Site
Critical Power Supplies - Liebert aps 16-bay 15kva 6batt 15000va tower black uninterruptible power supply (ups) image 22


>

4. IR Thermal Imaging Surveys - Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

.

Let us know what you think of this product

If you have purchased this from us in the past then please take some time to review the product, along with the quality of service you received from us!