Critical Power Supplies - Facebook-double Critical Power Supplies - Twitter-double Critical Power Supplies - Linkedin-double Critical Power Supplies - Google-plus-double 24 Hour: 0800 978 8988 Int: +44 (0)1844 340122
Find Your Supplies >

Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu)

Product (ex VAT):
Discontinued
Product (inc VAT):
Discontinued

HP Remote Monitored Power Distribution Units (PDU) provide rack level power monitoring over the network. With billing grade accuracy these PDUs are an excellent choice for data centers wanting to make the most of circuit capacity or for co-location facilities needing to precisely track power usage for billing purposes.

The low profile single piece design on these PDU’s provides multiple mounting options and ease of access to rear devices for maintenance. They are designed for HP racks but will also work in a large variety of third party racks as well.

They can be installed on either side of the rack with outlets facing the back of the rack for easy access and improved clearance. Also for higher power density they can be installed side by side on both sides of the rack with the outlets facing in towards the center of the rack.

HP Remote Monitored PDUs are available in 1U/0U and vertical form factors in single and 3-phase models and are back by HP’s limited 3-year warranty.

Accurate, flexible, and easy to use and manage make this the right PDU for many environments.
- 99% billing grade accuracy including energy usage (kW/Hour) improves circuit utilization while providing all the information needed for billing.
- Slim design and multiple mounting options allow for mounting on both sides of the rack or mounting multiple PDUs on one side.
- Web base interface is easy to configure while settable thresholds provide customization of alerts to match the specific needs and policies of a datacenter.
- Local and LDAP authentication provide security whether installed in a single SMB rack or an entire enterprise datacenter.

Design
PDU typesMonitored
Colour of productBlack
Power
Nominal input voltage220-240
Maximum current32 A
Load capacity7300 VA
Ports & interfaces
AC outlets quantity36 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power plugIEC 60309
Weight & dimensions
Dimensions (WxDxH)52 x 52 x 1691.4 mm
Weight5.46 kg
Part Number D9N50A

Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24x7 on our sales number.

1: Plug and Play (400-3kVA) - Extended Warranty Contracts from 1 to 5 years from £9.99 per month ex VAT

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your warranty up to 3 years, next working day replacement
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 1
Warranty Plus Extends your warranty up to 5 years, next working day replacement
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 2
Intervention, Provides one preventative maintenance visit, planned visit  
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 3
Battery Plus, Provides replacement batteries to site, next working day replacement
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 4
Warranty One Extends your warranty up to 1 year, next working day replacement  
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 5


2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

 

Technical Hotline 24/7
Yes
Yes
Yes
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 6
Preventative Maintenance
Yes
Yes
Yes
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 7
Remote Monitoring 24/7
Yes
Yes
Yes
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 8
Firmware Upgrades
Yes
Yes
Yes
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 9
Emergency Response
Yes
Yes
Yes
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 10
Labour
Yes
Yes
Yes
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 11
Parts
Yes
Yes
Yes
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 12
Monthly Event/Status Report
option
option
option
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 13
Onsite Crash Kit
option
option
option
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 14
Response Time
12 working hours
8 working hours
4 clock hours
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 15

 

3: 24x7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 16
24x7 flexible status and remote monitoring.      
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 17
Encrypted communication, allowing safe offsite monitoring    
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 18
Alarms and events emailed and SMS texted automatically    
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 19
Firewall Friendly
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 20
Cloud based status overview and multiple sites status on one screen
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 21
Allows First Fix Response to Site
Critical Power Supplies - Hewlett packard enterprise d9n50a 36ac outlet(s) black power distribution unit (pdu) image 22


>

4. IR Thermal Imaging Surveys - Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

.

Let us know what you think of this product

If you have purchased this from us in the past then please take some time to review the product, along with the quality of service you received from us!