Critical Power Supplies - Facebook-double Critical Power Supplies - Twitter-double Critical Power Supplies - Linkedin-double Critical Power Supplies - Google-plus-double 24 Hour: 0800 978 8988 Int: +44 (0)1844 340122
Find Your Supplies >

Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch

Product (ex VAT):
£7,167.67
Product (inc VAT):
£8,601.21
ETA 2 - 5 DAYS
Call for information

The Cisco Nexus 9396TX is a dense, line-rate 10GBase-T switch. It delivers comprehensive line-rate Layer 2 and Layer 3 overlays and the Cisco Application Centric Infrastructure (ACI) feature set. It is ideal for top-of-rack deployments in both traditional and ACI-enabled enterprise, service provider, and cloud environments.

The Cisco Nexus 9396TX Switch has 48 10GBase-T ports that can operate at 100 Mbps, 1 Gbps, and 10 Gbps speeds and 12 Quad Small Form Pluggable Plus (QSFP+) uplinks. All the ports are line rate, delivering 1.92 Tbps of throughput in a 2-rack-unit (2RU) form factor. The switch can be deployed as an access switch in traditional three-tier designs or as a leaf node in spine-leaf architectures.

ACI Support
– Integrated multi-hypervisor and bare-metal interoperation with VLAN and VxLAN routing and bridging support in ACI mode
– Single view of the entire fabric on APIC dashboard
– Full normalization of any encapsulation inside the fabric
– Consistent policy-based approach to deploying applications on top of the ACI fabric
– Fabric supports seamless integration of layer 4 (physical and virual) services in the end-to-end ACI policy framework
– Cohesive alignment of policies as workload moves around inside the fabric

Programmability
– Open APIs to manage the switch through remote-procedure calls (JavaScript Object Notation or XML) over HTTP or HTTPS
– Automated configuration through Linux shell scripts
– Support for customer applications through a Linux container environment

High Availability
– Hot-swappable, redundant power supplies and fan trays
– Full patching support

Energy Efficiency
– Power supplies that are rated at 80 Plus Platinum
– Support for front-to-back or back-to-front airflow configuration

Investment Protection
– 40 Gb bidirectional transceiver for reuse of existing 10 Gigabit Ethernet multimode cabling plant for 40 Gigabit Ethernet
– Support for Cisco NX-OS and ACI modes of operation

Management features
Switch typeManaged
Web-based managementYes
System event logYes
Quality of Service (QoS) supportYes
Multicast supportYes
Switch layerL3
Ports & interfaces
QSFP+ module slots quantity8
Basic switching RJ-45 Ethernet ports quantity48
Basic switching RJ-45 Ethernet ports type10G Ethernet (100/1000/10000)
Networking
VLAN supportYes
Spanning tree protocolYes
IGMP snoopingYes
10G supportYes
Data transmission
Throughput1500 Mpps
Number of multicast groups filtered32000
MAC address table96000 entries
Switching capacity1920 Gbit/s
Number of VLANs4096
Security
IGMP snoopingYes
Access Control List (ACL)Yes
Design
SafetyUL 60950-1 Second Edition, CAN/CSA-C22.2 No. 60950-1 Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, AS/NZS 60950-1, GB4943
Form factor2U
Colour of productGrey
LED indicatorsYes
Certification47CFR, AS/NZS CISPR22, CISPR22, EN55022, ICES003, VCCI, EN61000-3-2, EN61000-3-3, KN22, CNS13438, EN55024, CISPR24, EN300386, KN 61000
Rack mountingYes
Number of fans3 fan(s)
Performance
Packet buffer memory50 MB
Built-in processorYes
Processor frequency2500 MHz
Noise level68.3 dB
Internal memory16384 MB
Flash memory64 MB
Power
Power consumption (max)712 W
Power supply includedYes
AC input voltage100-240
AC input frequency50/60
Power consumption (typical)427 W
Technical details
Form factor2U
Colour of productGrey
Built-in processorYes
Processor frequency2500 MHz
Noise level68.3 dB
Rack mountingYes
Certificates
SafetyUL 60950-1 Second Edition, CAN/CSA-C22.2 No. 60950-1 Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, AS/NZS 60950-1, GB4943
Certification47CFR, AS/NZS CISPR22, CISPR22, EN55022, ICES003, VCCI, EN61000-3-2, EN61000-3-3, KN22, CNS13438, EN55024, CISPR24, EN300386, KN 61000
Memory
Packet buffer memory50 MB
Internal memory16384 MB
Flash memory64 MB
Indication
LED indicatorsYes
Operational conditions
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95%
Operating altitude0 - 4000 m
Weight & dimensions
Width445 mm
Depth571 mm
Height89 mm
Weight10.2 kg
Part Number N9K-C9396TX-RF

Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24x7 on our sales number.

1: Plug and Play (400-3kVA) - Extended Warranty Contracts from 1 to 5 years from £9.99 per month ex VAT

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your warranty up to 3 years, next working day replacement
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 1
Warranty Plus Extends your warranty up to 5 years, next working day replacement
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 2
Intervention, Provides one preventative maintenance visit, planned visit  
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 3
Battery Plus, Provides replacement batteries to site, next working day replacement
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 4
Warranty One Extends your warranty up to 1 year, next working day replacement  
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 5


2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

 

Technical Hotline 24/7
Yes
Yes
Yes
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 6
Preventative Maintenance
Yes
Yes
Yes
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 7
Remote Monitoring 24/7
Yes
Yes
Yes
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 8
Firmware Upgrades
Yes
Yes
Yes
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 9
Emergency Response
Yes
Yes
Yes
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 10
Labour
Yes
Yes
Yes
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 11
Parts
Yes
Yes
Yes
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 12
Monthly Event/Status Report
option
option
option
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 13
Onsite Crash Kit
option
option
option
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 14
Response Time
12 working hours
8 working hours
4 clock hours
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 15

 

3: 24x7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 16
24x7 flexible status and remote monitoring.      
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 17
Encrypted communication, allowing safe offsite monitoring    
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 18
Alarms and events emailed and SMS texted automatically    
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 19
Firewall Friendly
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 20
Cloud based status overview and multiple sites status on one screen
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 21
Allows First Fix Response to Site
Critical Power Supplies - Cisco n9k-c9396tx-rf managed l3 10g ethernet (100/1000/10000) 2u grey network switch image 22


>

4. IR Thermal Imaging Surveys - Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

.

Let us know what you think of this product

If you have purchased this from us in the past then please take some time to review the product, along with the quality of service you received from us!