SKU: PDU3XMV6G32 Categories: , , Brand: Tripp Lite

Tripp Lite PDU3XMV6G32 3-Phase Local Metered PDU, 23kW, 42 208-240V outlets (36 C13, 6 C19), IEC309 32A Red (3P+N+E) 360-415V Input, 0u vertical, TAA

  • Order Now. Speak to a Specialist. Call 0800 978 8988.
  • ETA will be advised upon ordering or call us on 0800 978 8988 for leadtime.

£735.19 Ex VAT
£882.23 Inc VAT

Delivery Costs

Find below some of our pricing costs for Critical Power Supplies online store.

England, Wales and Scottish Lowlands

2 to 3 Working Days - £4.99.
Next Working Day - £9.99.
Pre Noon, Pre 10:30am - Contact Us.

Scottish Lowlands Postcodes
AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9

Highlands, Northern Ireland, Channel Islands and Ireland

  • Scottish Highlands
    3 to 5 Working Days - £20

    Scottish Highlands Postcodes
    AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4

  • Northern Ireland
    3 to 5 Working Days - £50

  • Channel Islands
    3 to 5 Working Days - £25

  • Ireland
    5 to 7 Working Days - £99

  • Western Europe
    5 to 7 Working Days - £150 DAP
    DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.

Purchase this item and get 7351 Points - equivalent to the value of £7.35
Add to Wishlist

All major debit and credit cards accepted.

  • Description

    22.2kW 3 phase 360-415V input, 208-240V output Local Metered Power Distribution Unit / PDU Visual display with scroll function enables selection of breakered load banks 1-6 for output current reporting in amps, total kW output and PDU input voltage Attached IEC309 32A Red (3P+N+E) 3 phase 360-415V input, 6 ft. / 1.8m line cord 0U, 70 in. / 178cm vertical form factor supports installation in 2 or 4 post equipment racks 42 total 208-240V outlets (36 C13, 6 C19) arranged in 6 separately breakered single phase output load banks Included cord retention sleeves keep vital network equipment plugged in and continuously powered Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included) Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases

  • Technical Data
    Design
    On/off switchYes
    PDU typesMetered
    MountingVertical
    Product colourBlack
    CertificationTested to CE (IEC 60950-1, EN55022, EN55024), EN Class A (Emissions), TAA Compliant
    Rack capacity0U
    Housing materialMetal
    Ports & interfaces
    Master AC outlets quantity36
    Slave AC outlets quantity6
    AC outlets quantity42 AC outlet(s)
    AC outlet typesC13 coupler, C19 coupler
    Power plugIEC309
    Features
    Cable length1.83 m
    LED indicatorsYes
    CertificationTested to CE (IEC 60950-1, EN55022, EN55024), EN Class A (Emissions), TAA Compliant
    Ergonomics
    Cable length1.83 m
    LED indicatorsYes
    Power
    Maximum power23000 W
    Nominal input voltage380-400 V
    Nominal output voltage200-240 V
    Power protection featuresOverload
    Maximum current32 A
    Maximum total current draw per phase16 A
    AC input frequency50 – 60 Hz
    Weight & dimensions
    Dimensions (WxDxH)55.1 x 63.2 x 1778 mm
    Weight6.48 kg
    Width55.1 mm
    Depth63.2 mm
    Height1778 mm
    Package width150.1 mm
    Package depth1944.9 mm
    Package height175 mm
    Package weight9.3 kg
    Package dimensions (WxDxH)150 x 175 x 1945 mm
    Packaging data
    Package width150.1 mm
    Package depth1944.9 mm
    Package height175 mm
    Package weight9.3 kg
    Package dimensions (WxDxH)150 x 175 x 1945 mm
    Operational conditions
    Operating temperature (T-T)0 – 50 °C
    Storage temperature (T-T)-15 – 60 °C
    Operating relative humidity (H-H)5 – 95%
    Operating temperature (T-T)32 – 122 °F
    Operating altitude0 – 3000 m
    Technical details
    Sustainability certificatesRoHS
    Logistics data
    Products per master (outer) case1 pc(s)
    Country of originTaiwan
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

  • Downloads

Customers also bought…

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us