30 pieces of STE2 rev2 (LAN & WiFi) monitoring units. Plastic bag only (No paper box, No power adaptor (PoE), Temperature sensor (3m) included) - HWG-600799
Find out how you can order below
How to buy- Description
STE2 r2 can connect up to 5 Sensors (5 sensor values) via 2x RJ11 port (1-Wire & 1-Wire UNI) and up to 2 Detectors via DI (Digital Inputs) for dry contacts.
A built-in web server is used for device configuration. STE2 r2 is a device with SNMP support designated for remote monitoring Temperature, Relative Humidity and other external sensors.
Device can be connected via Ethernet or WiFi. When the measured temperature (humidity, voltage, ..) on the external sensor(s) exceeds the defined Min-Max range (Safe Range), STE2 r2 sends an email alert (SMS, Voice Call, ..). In device configuration is Alarms tab, where you can define up to 3 sets of targets and assign them to individual sensors.
STE2 r2 is Standalone Monitoring device, means the device can be fully configured via the web, can send emails itself (SMTP server), supports SNMP, etc.
Connection of the product to the Portal (SensDesk technology) is not enabled by default. The portal have to be manually activated as a functional extension (central device management, data history, SMS and Voice Call alerts).
Manufacture provides limited free of charge portal service (HWg-cloud.com) and paid service (SensDesk.com), check the Portal providers for other available portals.It is supplied with free HWg-PDMS windows software to create graphs and export data to MS Excel.
Mobile App HWg monitor (IOs & Android) display current sensor values from devices on the LAN (WiFi) together with sensor values from any SensDesk Technology based portal.
Features:- Up to 5 sensors (1-Wire + 1-Wire UNI) and 2 DI (Digital Inputs) for Detectors
- Alarm alerts by e-mail and text messages (SMS), STE2 r2 includes the option to dial the target number (requires external gateway)
- M2M communication protocols: SNMP, XML, WWW interface with HTTP(s)
- Connected via LAN and WiFi (built-in antenna) – simultaneous connection possible.
- NMS connectivity (SNMP MIB); simple installation; supports DHCP; supports TLS authentication (Gmail).
- A sensor or DI alarm sends an alert by e-mail, SMS or Ring.For Ring or SMS alarm use the HWg-SMS-GW3 gateway in the same LAN.
- SensDesk portal compatible device (IoT projects)
- Powered from included external 5V power adaptor or PoE.
- With the enclosed HWg-PDMS software, logged data can be exported to MS Excel.
- Compatible with a range of third party SW. Examples for programmers on using the product are available in the HWg-SDK (Borland C++, MS Visual, VB, C#, PHP, JAVA and more).
Applications and usage:- Air conditioning failure detection
- Monitoring of refrigerator or freezers
- Drug storage + reports (by SensDesk)
- Food storage
- Remote industrial environment monitoring
- Temperature and humidity monitoring
- CO2 monitoring
- Water Flood detection (spot detection / Water Leak Detection sensing cable)
- Electrical current monitoring
- Onsite Maintenance
Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.
1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT
For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.
Warranty Plus Extends your warranty up to 3 years, next working day replacement Warranty Plus Extends your warranty up to 5 years, next working day replacement Intervention, Provides one preventative maintenance visit, planned visit Battery Plus, Provides replacement batteries to site, next working day replacement Warranty One Extends your warranty up to 1 year, next working day replacement 2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT
No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.
Services Included
Silver Level
Gold Level
Platinum Level
Technical Hotline 24/7 Yes Yes Yes Preventative Maintenance Yes Yes Yes Remote Monitoring 24/7 Yes Yes Yes Firmware Upgrades Yes Yes Yes Emergency Response Yes Yes Yes Labour Yes Yes Yes Parts Yes Yes Yes Monthly Event/Status Report option option option Onsite Crash Kit option option option Response Time 12 working hours 8 working hours 4 clock hours 3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT
Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.
Engineer Installation and configuration during normal hours 24×7 flexible status and remote monitoring. Encrypted communication, allowing safe offsite monitoring Alarms and events emailed and SMS texted automatically Firewall Friendly Cloud based status overview and multiple sites status on one screen Allows First Fix Response to Site 4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.
- Reviews (0)
Product Reviews
Company Reviews
Our brands
Shown below is a small selection of some of our customers we have helped through understanding clients challenges and implementing our unique approach to helping clients built around: listening to our clients, understanding the challenges they face and providing a range of options which compliments their requirements. Our aim is not to sell products but provide solutions with the help of our in house Power Consultants and Electricians.







Reviews
There are no reviews yet.