The *GE Digital Energy’s GT 10kVA UPS* from Critical Power Supplies Ltd is a true VFI (Voltage and Frequency Independent) on line, double conversion transformerless UPS incorporating the most advanced power electronics technology and engineered to provide the highest level of protection for all critical loads from all utility variances and failure.
– Features and Benefits Tower and/or rack design Maximum site flexibility; all necessary parts delivered in packing box
– Backfeed protection as standard Ensuring site safety without additional installation requirements
– Matching battery cabinets Extended runtime for all models
– Programmable load shutdown Remote on/off switching for isolated or unmanned sites
– Hot swappable batteries Easy battery replacement without disconnecting the load
– Hot swappable power pack Easy replacement of power unit without disconnecting the load
– Cold start UPS can start up without utility present
– Key Specifications Single Phase Output Voltages 220/230/240V
– Wide input voltage window 84-276V Minimizes battery use, prolongs battery life
– Redundant and paralleling capability UPS capacity can be increased as site requirements require at no extra cost
– Internal automatic bypass switch Continuous power supply to the load even if the UPS is overloaded
– No load shutdown Prevents deep battery discharge al low loads- Frequency conversion 50/60Hz Operates as a frequency converter also operating in a parallel system
– Emergency shutdown Easy implementation with standard UPS for ultimate site safety
Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.
1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts
For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.
| Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. | |
| Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. | |
| Battery Plus, Provides replacement batteries to site, next working day replacement or same day |
2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts
No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.
|
Services Included |
Silver Level |
Gold Level |
Platinum Level |
Platinum Plus |
|
| Technical Hotline 24/7 | Yes | Yes | Yes | Yes | |
| Preventative Maintenance | Yes | Yes | Yes | Yes | |
| Remote Monitoring 24/7 | Yes | Yes | Yes | Yes | |
| Firmware Upgrades | Yes | Yes | Yes | Yes | |
| Emergency Response | Yes | Yes | Yes | Yes | |
| Labour | Yes | Yes | Yes | Yes | |
| Parts | Yes | Yes | Yes | option | |
| Monthly Event/Status Report | option | option | option | option | |
| Onsite Crash Kit | option | option | option | onsite | |
| Response Time | 12 working hours | 8 working hours | 4 clock hours | 4 clock hours | |
| Guaranteed Fix time | – | – | – | 4 Clock hours |
3: 24×7 Remote Monitoring Contracts –
Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.
| Engineer Installation and configuration during normal hours | |
| 24×7 flexible status and remote monitoring. | |
| Encrypted communication, allowing safe offsite monitoring | |
| Alarms and events emailed and SMS texted automatically | |
| Firewall Friendly | |
| Cloud based status overview and multiple sites status on one screen | |
| Allows First Fix Response to Site |
4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.
Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.
5. Switchgear – Contact us for more information.
Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.
- Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
- Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
- Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.
Our brands
Shown below is a small selection of some of our customers we have helped through understanding clients challenges and implementing our unique approach to helping clients built around: listening to our clients, understanding the challenges they face and providing a range of options which compliments their requirements. Our aim is not to sell products but provide solutions with the help of our in house Power Consultants and Electricians.