      NetShelter Rack LCD Consoles Features & Benefits

      Agility

      On-Screen Display (OSD) adjustments Adjust the on-screen image, including: auto adjust, exit, power on/off, brightness, menu, and a power indicator.

      Quick release tabs Insert or remove the device with ease.

      Cable management arm Prevent interference with surrounding devices by organizing multiple cables.

      Slide rails Quickly and easily install in square, round, and threaded hole racks.

      Marketing features

      Occupies 1U of rack space Occupies only 1U of rack space. Traditional CRT monitors require 10U to 13U.

      Full Size Keyboard Full size keyboard with integrated number pad.

      Total cost of Ownership

      Multi-platform Support Windows, Sun, Unix and Linux compatible.

      Occupies 1U of rack space Conserve valuable rack space in the data center.

      Low Cooling Requirements Emits less heat than comparable CRT monitors .

      Low power consumption Uses less than half the power of comparable CRT monitors.

      Power tilt sensor Save power by automatically powering down the device when it is closed.

      PS/2 terminations Connect to a server or KVM switch via standard PS/2 connectors.

      Standard VGA termination Connects to a server or KVM switch via a standard VGA connector.

      Integrated touchpad pointing device Integrated Trackball Eliminates the need for a separate, external mouse.

    • Technical Data

      Input

      Input frequency 50/60 Hz
      Input Power 19 Watts

      Physical

      Maximum Height 44MM, 4.4CM
      Maximum Width 482MM, 48.2CM
      Maximum Depth 614MM, 61.4CM
      Net Weight 15.9KG
      Shipping weight 19.46KG
      Shipping Height 152MM, 15.2CM
      Shipping Width 673MM, 67.3CM
      Shipping Depth 826MM, 82.6CM
      Color Black
      Maximum Mounting Depth 1050.0MM, 104.98CM
      Minimum Mounting Depth 680.0MM, 68.0CM

      Environmental

      Operating Temperature 0 – 40 °C

      Conformance

      Approvals C-Tick, EN 55022 class A, EN 55024, EN 60950, FCC part 15 class A, GOST, IEC 60950, Industry Canada, NOM, UL listed, VDE
      Standard warranty 2 years repair or replace

      Sustainable Offer Status

      RoHS Compliant

      ts_Supported_Hardware

      Display Colors 16.0
      Panel Size 432.0Diagonal Inches
      LCD Power Consumption 19 Watts
      Pixel Pitch 0.26
      Trackball Type PS/2 touchpad, USB mouse
    • Onsite Maintenance

      Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

      1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

      For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

      Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
      Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
      Intervention, Provides one preventative maintenance visit, planned visitGreen tick
      Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
      Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

      2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

      No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

      Services Included

      Silver Level

      Gold Level

      Platinum Level

       

      Technical Hotline 24/7YesYesYesGreen tick
      Preventative MaintenanceYesYesYesGreen tick
      Remote Monitoring 24/7YesYesYesGreen tick
      Firmware UpgradesYesYesYesGreen tick
      Emergency ResponseYesYesYesGreen tick
      LabourYesYesYesGreen tick
      PartsYesYesYesGreen tick
      Monthly Event/Status ReportoptionoptionoptionGreen tick
      Onsite Crash KitoptionoptionoptionGreen tick
      Response Time12 working hours8 working hours4 clock hoursGreen tick

      3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

      Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

      Engineer Installation and configuration during normal hoursGreen tick
      24×7 flexible status and remote monitoring.Green tick
      Encrypted communication, allowing safe offsite monitoringGreen tick
      Alarms and events emailed and SMS texted automaticallyGreen tick
      Firewall FriendlyGreen tick
      Cloud based status overview and multiple sites status on one screenGreen tick
      Allows First Fix Response to SiteGreen tick

      4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

      Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

      Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    • Downloads

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.