APC Back-UPS 325, 230V, IEC 320, without auto shutdown software - BK325I

  • In Stock, 28 Available to order.
  • Order within for delivery on .

£68.12 Ex. VAT £81.74 Inc. VAT

Warranty: 1 Year

All major debit and credit cards accepted.

  • Description

    Back-UPS Features & Benefits

    Safety

    Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

    Marketing features

    Battery-protected and surge-only outlets Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

    Protection

    Surge only outlets Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

    Battery and surge protected outlets Back up and protect your hardware and data during power outages, surges and spikes .

    Availability

    Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.

    Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance

    Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.

    Manageability

    LED status display Quickly understand unit and power status with visual indicators.

    Audible alarms Provides notification of changing utility power and UPS power conditions

  • Technical Data

    Output

    Max Configurable Power (Watts)210 Watts
    / 350VA
    Output Frequency (sync to mains)47 – 63 Hz Sync to mains, 50/60 Hz +/- 1 Hz Unsynchronised
    TopologyStandby
    Waveform typeStepped approximation to a sinewave
    Transfer Time6 ms typical : 10 ms maximum

    Input

    Input frequency50/60 Hz +/- 3 Hz Auto-sensing
    Input voltage range for main operations180 – 266V
    Number of Power Cords1

    Batteries & Runtime

    Battery typeLead-acid battery
    Typical recharge time6hour(s)
    Nominal Battery Voltage12 V
    Replacement BatteryRBC2
    Expected Battery Life (years)4 – 6
    RBC Quantity1
    Battery Charge Power (Watts)14 Watts
    RuntimeView Runtime Graph
    EfficiencyView Efficiency Graph

    Communications & Management

    Control panelLED status display with on line : on battery : replace battery and overload indicators
    Audible AlarmAlarm when on battery : distinctive low battery alarm : overload continuous tone alarm

    Surge Protection and Filtering

    Surge energy rating310Joules
    FilteringFull time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449

    Physical

    Maximum Height165MM, 16.5CM
    Maximum Width91MM, 9.1CM
    Maximum Depth284MM, 28.4CM
    Net Weight5.73KG
    Shipping weight6.73KG
    Shipping Height178MM, 17.8CM
    Shipping Width241MM, 24.1CM
    Shipping Depth368MM, 36.8CM
    ColorBeige
    Master Carton Units2.0
    Units per Pallet48.0

    Environmental

    Operating Temperature0 – 40 °C
    Operating Relative Humidity0 – 95 %
    Operating Elevation0 – 3048meters
    Storage Temperature-15 – 45 °C
    Storage Relative Humidity0 – 95 %
    Storage Elevation0 – 15240meters
    Online thermal dissipation19.0BTU/hr

    Conformance

    ApprovalsC-Tick, CE, EN 50091-1, EN 50091-2, GOST, VDE
    Standard warranty2 years repair or replace

    Sustainable Offer Status

    RoHSCompliant
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

  • Downloads

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us