SKU: BR1600SI Categories: , , , Brand: APC Tag:

APC Back UPS Pro Br1600si

  • In Stock, 1 Available to order.
  • Order within for delivery on .
We are an APC Premier Partner!

£435.08 Ex VAT
£522.1 Inc VAT

Delivery Costs

Find below some of our pricing costs for Critical Power Supplies online store.

England, Wales and Scottish Lowlands

2 to 3 Working Days - £4.99.
Next Working Day - £9.99.
Pre Noon, Pre 10:30am - Contact Us.

Scottish Lowlands Postcodes
AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9

Highlands, Northern Ireland, Channel Islands and Ireland

  • Scottish Highlands
    3 to 5 Working Days - £20

    Scottish Highlands Postcodes
    AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4

  • Northern Ireland
    3 to 5 Working Days - £50

  • Channel Islands
    3 to 5 Working Days - £25

  • Ireland
    5 to 7 Working Days - £99

  • Western Europe
    5 to 7 Working Days - £150 DAP
    DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.

Purchase this item and get 4350 Points - equivalent to the value of £4.35
Add to Wishlist

All major debit and credit cards accepted.

  • Description

    Back-UPS Pro Features & Benefits

    Manageability

    Audible alarms Provides notification of changing utility power and UPS power conditions

    Disconnected battery notification Warns when a battery is not available to provide backup power.

    LCD Status Display Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

    USB connection Use your PC to access additional power protection and management features for your UPS via a USB Port.

    Safety

    Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

    Marketing features

    Battery-protected and surge-only outlets Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment

    Boost Automatic Voltage Regulation (AVR) Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.

    Serviceability

    Simple battery replacement Increases UPS availability by allowing quick, easy battery replacement.

    Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)

    Availability

    Green mode Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

    Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.

    Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).

    Cold-start capable Provides temporary battery power when the utility power is out.

    Customizable voltage sensitivity Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.

    Customizable voltage-transfer points Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.

    Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.

    Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance

    Transformer-block spaced outlets Protect equipment with input transformer blocks without blocking access to other receptacles.

    Protection

    Surge only outlets Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.

    Battery and surge protected outlets Back up and protect your hardware and data during power outages, surges and spikes .

    Dataline surge protection Provides protection of connected equipment from power surges on the data lines.

  • Technical Data

    Output

    Max Configurable Power (Watts)960 Watts
    / 1.6kVA
    Output Frequency (sync to mains)50/60 Hz +/- 1 Hz Sync to mains
    TopologyLine interactive

    Input

    Input frequency50/60 Hz +/- 3 Hz Auto-sensing
    Input voltage range for main operations176 – 294V

    Batteries & Runtime

    Battery typeLead-acid battery
    Typical recharge time16hour(s)
    Nominal Battery Voltage24 V
    Replacement BatteryAPCRBC163
    Expected Battery Life (years)3 – 5
    RBC Quantity1
    Battery Charge Power (Watts)16 Watts
    RuntimeView Runtime Graph
    EfficiencyView Efficiency Graph

    Communications & Management

    Interface Port(s)USB
    Control panelMultifunction LCD status and control console
    Audible AlarmAlarm when on battery : distinctive low battery alarm : overload continuous tone alarm

    Surge Protection and Filtering

    Surge energy rating509Joules
    Data Line ProtectionRJ45 10/100/1000 Base-T Ethernet protection
    FilteringFull time multi-pole noise filtering : 10% of IEEE surge let-through : zero clamping response time: instantaneous

    Physical

    Maximum Height260MM, 26.0CM
    Maximum Width100MM, 10.0CM
    Maximum Depth368MM, 36.8CM
    Net Weight12.1KG
    Shipping weight13.75KG
    Shipping Height359MM, 35.9CM
    Shipping Width223MM, 22.3CM
    Shipping Depth482MM, 48.2CM
    ColorBlack
    Master Carton Dimensions (Length x Width x Height)381 x 483 x 229MM
    Master Carton Units1.0
    Master Carton Weight14.61
    SCC Codes10731304346927

    Environmental

    Operating Temperature0 – 40 °C
    Operating Relative Humidity0 – 95 (Non-condensing) %
    Operating Elevation0 – 3048meters
    Storage Temperature-15 – 45 °C
    Storage Relative Humidity0 – 95 (Non-condensing) %
    Storage Elevation0 – 15240meters
    Audible noise at 1 meter from surface of unit45.0dBA
    Online thermal dissipation20.0BTU/hr

    Conformance

    ApprovalsA-Tick, C-Tick, CE, EAC, GS Mark, RCM, TISI
    Equipment protection policyLifetime : 150000 euros, Lifetime : 200000 AUD, Lifetime : 75000 GBP
    Standard warranty2 years repair or replace, 3 years repair or replace for European Union countries

    Sustainable Offer Status

    RoHSCompliant
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.