Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988
Categories: , , Brand: APC Tag:

APC Smart-UPS On-Line, 8kVA/8kW, Rack/Tower, 230V, 2x IEC C13+1x IEC C19+Hard wire 3-wire (H+N+E) outlets, Network Card, W/O rail kit

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups
    We are an APC Premier Partner!
    Tailor to your needs. Speak to a Specialist.
    Call: 0800 978 8988

    Need a quote?

    All major debit and credit cards accepted.

    This APC Smart-UPS is designed for IT professionals or network administrators to maintain business uptime and continuity. This 8kVA on-line rack/tower UPS provides pure sine wave power and extended runtime to support critical electronics during power disruptions. It comes with hard wire 3-wire (1P+N+E) input, 2x IEC 320 C13, 1x IEC 320 C19 and Hard wire 3-wire (H+N+E) outlets. The UPS has an embedded Network Management Card for UPS network-based monitoring and management. The UPS comes with PowerChute Network Shutdown that provides graceful shutdown of physical servers, virtual machines, and HCI clusters. The UPS can connect to EcoStruxure IT or third-party centralized management platforms. The UPS has a 3-year warranty, and the built-in lead-acid battery has a 2-year warranty. The UPS is compatible with SRTGRK1 rail kit sold separately.

    Replacement battery (1) is available
    To Review the SRTG8KXLI Runtime Chart Click here
    8kVA/8kW double-conversion on-line pure sine wave rack/tower UPS
    Ideal for servers, storage, voice/data networks, medical labs, and light industrial applications
    Rack/tower convertible (SRTGRK1 rail kit sold separately)
    1-Year Secure Network Management Card subscription included

    Add up to 4 external battery packs (SRTG192XLBP4) for extended runtime

    Specifications

    Power
    Output power 8000 W
    Input operation voltage (min) 100 V
    Input operation voltage (max) 285 V
    Output operation voltage (min) 220 V
    Output operation voltage (max) 240 V
    Output voltage Total Harmonic Distortion (THD) 2%
    Output power capacity 8 kVA
    ECO mode Yes
    Performance
    Audible alarm modes Alarm when on battery, Low battery alarm, Overload alarm
    UPS topology Double-conversion (Online)
    Waveform Sine
    Auto-restart Yes
    LED indicators Yes
    Noise level 55 dB
    Audible alarm(s) Yes
    Features
    Output frequency 50/60 Hz
    Audible alarm modes Alarm when on battery, Low battery alarm, Overload alarm
    UPS topology Double-conversion (Online)
    Waveform Sine
    Auto-restart Yes
    Output power 8000 W
    Input operation voltage (min) 100 V
    Input operation voltage (max) 285 V
    Output operation voltage (min) 220 V
    Output operation voltage (max) 240 V
    Output voltage Total Harmonic Distortion (THD) 2%
    Noise level 55 dB
    Audible alarm(s) Yes
    Output power capacity 8 kVA
    ECO mode Yes
    Input frequency 40/70 Hz
    Ports & interfaces
    Emergency Power Off (EPO) connector Yes
    USB port Yes
    Serial interface Yes
    AC outlets quantity 3 AC outlet(s)
    AC outlet types C13 coupler, C19 coupler
    Power plug Hardwire
    Ethernet LAN (RJ-45) ports 1
    Battery
    Battery life (max) 5 year(s)
    Number of batteries supported 2
    Battery voltage 96 V
    Battery technology Sealed Lead Acid (VRLA)
    Battery recharge time 4 h
    Hot-swap battery Yes
    Cold start Yes
    Automatic battery test Yes
    Design
    International Protection (IP) code IP20
    Form factor Rackmount/Tower
    LED indicators Yes
    Certification CE, EN/IEC 62040-1
    Display type LCD
    Operational conditions
    Operating temperature (T-T) 0 – 40 °C
    Storage temperature (T-T) -15 – 45 °C
    Operating relative humidity (H-H) 0 – 95%
    Storage relative humidity (H-H) 0 – 95%
    Operating altitude 0 – 2011.68 m
    Non-operating altitude 0 – 15240 m
    Technical details
    Output frequency 50/60 Hz
    Weight & dimensions
    Package width 590 mm
    Package depth 790 mm
    Package height 414 mm
    Weight 81.1 kg
    Width 440 mm
    Package weight 83.1 kg
    Height 217 mm
    Depth 620 mm
    Packaging data
    Package width 590 mm
    Package depth 790 mm
    Package height 414 mm
    Package weight 83.1 kg
    Certificates
    Certification CE, EN/IEC 62040-1

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us