Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988

APC Smart-UPS VT 20kVA Online 400V with 2 Battery Modules (UPS) - SUVTP20KH2B2S

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups
    We are an APC Premier Partner!

    £7895.56 Ex VAT
    £9474.67 Inc VAT

    Delivery Costs

    Find below some of our pricing costs for Critical Power Supplies online store.

    England, Wales and Scottish Lowlands

    2 to 3 Working Days - £4.99.
    Next Working Day - £9.99.
    Pre Noon, Pre 10:30am - Contact Us.

    Scottish Lowlands Postcodes
    AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9

    Highlands, Northern Ireland, Channel Islands and Ireland

    • Scottish Highlands
      3 to 5 Working Days - £20

      Scottish Highlands Postcodes
      AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4

    • Northern Ireland
      3 to 5 Working Days - £50

    • Channel Islands
      3 to 5 Working Days - £25

    • Ireland
      5 to 7 Working Days - £99

    • Western Europe
      5 to 7 Working Days - £150 DAP
      DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.

    Purchase this item and get 78955 Points - equivalent to the value of £78.96

    In Stock — 1 available to order

    Delivery
    Delivery options, charges and estimated delivery times are shown at checkout.
    Need this urgently? Contact Sales to confirm availability and delivery options.
    Call 0800 978 8988

    All major debit and credit cards accepted.

    Smart-UPS VT Features & Benefits

    Total cost of Ownership

    Temperature-compensated battery charging

    Prolongs battery life by regulating the charge voltage according to battery temperature.
    Input Power Factor Correction

    Minimizes installation costs by enabling the use of smaller generators and cabling.
    Intelligent battery management

    Maximizes battery performance, life, and reliability through intelligent, precision charging.
    Manual maintenance bypass

    Reduces installation costs by eliminating the need for an external mechanical bypass.

    Sustainability

    EU CoC for UPS

    Ensures that UPSs sold in the EU are highly efficient

    Serviceability

    Shippable with modules installed

    Enables pre-installation UPS staging and testing and faster installation.
    Automatic self-test

    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
    Battery replacement without tools

    Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
    Modular design

    Provides scalability, N+1 redundancy, fast serviceability, and reduced maintenance requirements via self-diagnosing, hot-swappable, and field-replaceable modules.

    Protection

    Safety-agency approved

    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
    Cold-start capable

    Provides temporary battery power when the utility power is out.
    Frequency and voltage regulation

    Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

    Marketing features

    Hot-swappable batteries

    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

    Manageability

    SmartSlot

    Customize UPS capabilities with management cards.
    Audible alarms

    Provides notification of changing utility power and UPS power conditions
    InfraStruXure Manager Compatible

    Enables centralized management via the APC InfraStruXure Manager.
    LCD display

    Alpha-Numeric Display which displays system parameters and alarms.
    LED status indicators

    Quickly understand unit and power status with visual indicators.
    Network manageable

    Provides remote power management of the UPS over the network.
    Programmable frequency

    Ensures compatibility with different input frequencies.

    Availability

    Dual mains input

    Increases availability by allowing the UPS to be connected to two separate power sources.
    Automatic internal bypass

    Supplies utility power to the connected loads in the event of a UPS power overload or fault.
    Generator compatible

    Ensures clean, uninterrupted power to protected equipment when generator power is used.
    Scalable runtime

    Allows additional run time to be quickly added as needed.
    Battery modules connected in parallel

    Delivers higher availability through redundant batteries.
    Power
    Output power 16000 W
    Maximum current 27 A
    Emergency Power Off (EPO) Yes
    Output power capacity 20000 VA
    Battery
    Battery type VRLA
    Battery technology Sealed Lead Acid (VRLA)
    Battery recharge time 5 h
    Replacement battery cartridge 2
    Performance
    Noise level 64 dB
    Features
    Output power 16000 W
    Maximum current 27 A
    Emergency Power Off (EPO) Yes
    Noise level 64 dB
    Output power capacity 20000 VA
    Input frequency 40/70 Hz
    Design
    Product colour Black
    Certification C-tick,CE,EN 50091-2,EN/IEC 62040-3,IEC 61000-3-2,IEC 61000-3-3,ISO 14001,ISO 9001,VFI-SS-112
    Operational conditions
    Operating temperature (T-T) 0 – 40 C
    Storage temperature (T-T) -15 – 45 C
    Operating relative humidity (H-H) 0 – 95%
    Storage relative humidity (H-H) 0 – 95%
    Operating altitude 0 – 999.9 m
    Non-operating altitude 0 – 15000 m
    Packaging data
    Package dimensions (WxDxH) 650 x 1062 x 1643 mm
    Package weight 428.2 kg
    Weight & dimensions
    Weight 396.8 kg
    Package weight 428.2 kg
    Logistics data
    Quantity per pallet 1 pc(s)
    Certificates
    Certification C-tick,CE,EN 50091-2,EN/IEC 62040-3,IEC 61000-3-2,IEC 61000-3-3,ISO 14001,ISO 9001,VFI-SS-112
    Other features
    Battery type VRLA
    Output connections 1 x Hard Wire 4-wire (3PH + G)
    1 x Hard Wire 5-wire (3PH + N + G)
    1 x Screw Terminals
    Input connection type Hard Wire 5-wire (3PH + N + G)
    Dimensions (WxDxH) 356 x 812 x 1499 mm
    Package dimensions (WxDxH) 650 x 1062 x 1643 mm
    Nominal input voltage 400 V

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.