SKU: SMARTINT2200VS Categories: , Brand: Tripp Lite Tag:

Tripp Lite SmartPro 230V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Network Card Options, USB, DB9 Serial - SMARTINT2200VS

  • Temporarily out of stock. Still available to order. Secure your product.
  • ETA will be advised upon ordering or call us on 0800 978 8988 for leadtime.

Tailor to your needs. Speak to a Specialist.
Call: 0800 978 8988

  • Description
    • SMARTINT2200VS line interactive UPS offers protection from blackouts, brownouts, overvoltages and surges
    • 2200VA/1600W capacity
    • Internal batteries support a half load of 1500VA for 19 and a full load of 2200VA for 7
    • An intelligent battery management system extends battery life
    • Maintains regulated 230V noal output during brownouts and overvoltages from 171 to 282V
    • Includes 9 UPS supported outlets with 3 individually controllable load banks that can be powered off and back on again via software interface
    • IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
    • Optional WEBCARDLXwith the latest version of PowerAlert Device Manager firmware provides enhanced remote management capabilities
    • PADM20 and PowerAlert Element Manager form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
    • IP-based Auto Probe detects lost connectivity and restores service autonomously
    • USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite’s PowerAlert software, available via FREE download.
    • Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for immediate reboot of connected devices
    • Supports Tripp Lite’s WatchDog software application
    • Built-in accessory slot supports Network Management Card options; Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX and SNMPWEBCARD
    • Emergency Power Offinterface with cable
    • Multi-function audible alarms and set of 5 front panel LEDs
    • Network-grade AC surge suppression
    • Attractive gray color scheme
    • Optional PDUBHV20 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
  • Technical Data
    OVERVIEW
    UPC Code037332120304
    UPS TypeLine-Interactive
    INPUT
    Rated input current (Maximum Load)11.3A
    Nominal Input Voltage(s) Supported230V AC
    UPS Input Connection TypeC20 inlet
    UPS Input Connection DescriptionIEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
    Input PhaseSingle-Phase
    OUTPUT
    Output Volt Amp Capacity (VA)2200
    Output Capacity (kVA)2.20
    Output Watt Capacity (Watts)1600
    Output kW Capacity (kW)1.60
    Power Factor  0.7
    Nominal Voltage Details230v inverter nominal output voltage
    Frequency Compatibility50 / 60 Hz
    Frequency Compatibility DetailsAutomatic frequency selection
    Output Voltage Regulation (Line Mode)-19% +8%
    Output Voltage Regulation (Battery Mode)+/- 5%
    Included Output Power CablesIncludes 3 C13 to C14 output power cables
    Load Management Receptacles  Three switchable two-outlet C13 load banks
    Output Circuit Breakers10A (x2) – each breaker protects 4 C13 outlets each, C19 is unbreakered
    Hot-Swap PDU optionsPDUBHV20 (2U / 6 C13, 2 C19 outlets)
    Output AC Waveform (AC Mode)Sine wave
    Output AC Waveform (Battery Mode)PWM sine wave
    Nominal Output Voltage(s) Supported220V; 230V; 240V
    Output Receptacles(8) C13; (1) C19
    Individually Controllable Load Banks  Yes
    BATTERY
    Battery TypeValve Regulated Lead Acid (VRLA)
    Full Load Runtime (min.)  7 min. (1600w)
    Half Load Runtime (min.)  19 min. (800w)
    Expandable RuntimeNo
    DC System Voltage (VDC)48
    Battery Recharge Rate (Included Batteries)Less than 4 hours from 10% to 90% (typical, full load discharge)
    Battery AccessBattery access door
    Internal UPS Replacement Battery Cartridge RBC54
    Battery Replacement DescriptionHot-swappable, user replaceable batteries
    VOLTAGE REGULATION
    Voltage Regulation DescriptionAutomatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V
    Overvoltage Correction  Input voltages between 245 and 282 are reduced by 12%
    Undervoltage Correction  Input voltages between 177 and 199 are boosted by 14%
    Severe Undervoltage CorrectionInput voltages between 151 and 176 are boosted by 30%
    USER INTERFACE, ALERTS & CONTROLS
    Switches2 Switches control off/on power status and alarm-cancel/self-test operation
    Alarm Cancel OperationPower-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
    Audible AlarmAudible alarm indicates power-failure, overload and low-battery conditions
    LED Indicators5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
    SURGE / NOISE SUPPRESSION
    UPS AC Suppression Joule Rating480
    UPS AC Suppression Response TimeInstantaneous
    EMI / RFI AC Noise Suppression  Yes
    PHYSICAL
    Primary Form FactorTower
    Cooling MethodFan
    Installation Form Factors Supported with Included AccessoriesTower
    Primary UPS Depth (mm)305
    Primary UPS Height (mm)361
    Primary UPS Width (mm)234
    Shipping Dimensions (hwd / cm)49.02 x 38.61 x 40.39
    Shipping Weight (kg)27.49
    UPS Housing MaterialPolycarbonate
    UPS Power Module Dimensions (hwd, cm)36.07 x 23.37 x 30.48
    UPS Power Module Weight (kg)24.49
    ENVIRONMENTAL
    Operating Temperature Range+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
    Storage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
    Relative Humidity0 to 95%, non-condensing
    AC Mode Efficiency Rating (100% Load)94%
    Audible NoiseAudible Noise < 47dBA At Front Side 1 Meter
    COMMUNICATIONS
    Network Management Cards SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX
    Network Monitoring Port DescriptionSupports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total)
    PowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
    Communications Cable2 USB and 2 DB9 cables included
    WatchDog CompatibilitySupports Watchdog application, OS and hard-reboot restart options for remote applications
    Network Management Card DescriptionNetwork management card optional
    Communications InterfaceContact closure; DB9 Serial; Slot for SNMP/Web interface; USB
    LINE / BATTERY TRANSFER
    Transfer Time  2-4 milliseconds
    Low Voltage Transfer to Battery Power (Setpoint)151
    High Voltage Transfer to Battery Power (Setpoint)282
    FEATURES & SPECIFICATIONS
    Cold Start (Startup in Battery Mode During a Power Failure)Cold-start operation supported
    High Availability UPS Features  Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection
    STANDARDS & COMPLIANCE
    UPS CertificationsCE; Meets FCC Part 15 Category A (EMI)
    Certification DetailsCE 62040
    WARRANTY
    Product Warranty Period (International)2-year limited warranty
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

  • Downloads

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us