Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988

APC Symmetra RM 2kVA Scalable to 6kVA N+1 220-240V - SYH2K6RMI

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups
  • Order Now. Speak to a Specialist. Call 0800 978 8988.
  • ETA will be advised upon ordering or call us.
We are an APC Premier Partner!

£4014.06 Ex VAT
£4816.87 Inc VAT

Delivery Costs

Find below some of our pricing costs for Critical Power Supplies online store.

England, Wales and Scottish Lowlands

2 to 3 Working Days - £4.99.
Next Working Day - £9.99.
Pre Noon, Pre 10:30am - Contact Us.

Scottish Lowlands Postcodes
AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9

Highlands, Northern Ireland, Channel Islands and Ireland

  • Scottish Highlands
    3 to 5 Working Days - £20

    Scottish Highlands Postcodes
    AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4

  • Northern Ireland
    3 to 5 Working Days - £50

  • Channel Islands
    3 to 5 Working Days - £25

  • Ireland
    5 to 7 Working Days - £99

  • Western Europe
    5 to 7 Working Days - £150 DAP
    DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.

Please email me when stock is available

All major debit and credit cards accepted.

Symmetra Features & Benefits

Availability

Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.

Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Configurable for N+1 internal redundancy Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Battery modules connected in parallel Delivers higher availability through redundant batteries.

Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.

Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures.

Modular design Provides scalability, N+1 redundancy, fast serviceability, and reduced maintenance requirements via self-diagnosing, swappable, and field-replaceable modules.

Hot-swappable power modules Ensures clean, uninterrupted power to protected equipment during Power Module replacement.

Hot-swappable intelligence modules Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.

Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

Serviceability

User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Predictive failure notification. Provides early-warning fault analysis ensuring proactive component replacement.

Disconnected battery notification Warns when a battery is not available to provide backup power.

User-replaceable power modules Enables simple upgrades and replacements of the Power Modules.

User-replaceable intelligence modules Enables simple upgrades and replacements of the Intelligence Modules.

Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Audible alarms Provides notification of changing utility power and UPS conditions.

Protection

Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Resettable circuit breakers Enables a quick recovery from overload events.

Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.

Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.

Generator compatible Ensures clean, uninterrupted power to the loads in the event of an extended power outage

Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Cold-start capable Provides temporary battery power when the utility power is out.

Scalability

Programmable frequency Ensures compatibility with different input frequencies.

Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

Field-replaceable power distribution panel Ensures compatibility with equipment that has different plug types.

Scalable runtime Allows additional run time to be quickly added as needed.

Scalable power capacity Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.

Manageability

SmartSlot Customize UPS capabilities with management cards.

Network manageable Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.

Manageable external batteries Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.

LCD display Alpha-Numeric Display which displays system parameters and alarms.

Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.

InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure Manager.

Marketing features

Peace of mind that comes with complete equipment compatibility and reliability of a market leader . Safety agency tested and approved means that you can deploy Symmetra with confidence that they meet or exceed the industry?s most rigorous standards.

Avoids costly power problems by keeping your IT equipment and data protected and available . Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.

Modular, Scalable, Redundant Architecture future proof initial investment, improves equipment availability, and simplifies maintenance. Symmetra LX?s redundant N+1 architecture enables the unit to withstand a failures of an intelligence module, battery or power module. Modules are easily replaceable in the field. Customers can add additional power modules or batteries after initial equipment purchase to accommodate loads of up to 16 kVA.

Save time with easy and convenient remote accessibility. Network manageable via serial, USB or optional Ethernet. Includes Powerchute? Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.

Low operating and maintenance costs with proven reliability and intelligent battery management . Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.

Output

Max Configurable Power (Watts) 4.2kWatts
/ 6.0kVA
Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage
Efficiency at Full Load 89.0 %
Output Voltage Distortion Less than 5 % at full load
Output Frequency (sync to mains) 47 – 53 Hz For 50 Hz nominal Sync to mains, 50 Hz +/- 0.1 % For 50 Hz nominal Unsynchronised
Load Crest Factor Up to 5 : 1
Topology Double conversion online
Waveform type Sine wave
Bypass Internal bypass (automatic and manual)

Input

Input frequency 50/60 Hz +/- 5 Hz Auto-sensing
Input voltage range for main operations 155 – 276V
Number of Power Cords 1
Efficiency at Full Load 89.0 %
Input Power Factor at Full Load 0.98

Batteries & Runtime

Battery type Lead-acid battery
Included Battery Modules 1
Typical recharge time 4hour(s)
Battery Slots Empty 4
Expected Battery Life (years) 3 – 5
Replacement battery cartridge note UPS accepts 1-4 additional battery packs
Battery Charge Power (Watts) 153 Watts
Extendable Run Time 1
Runtime View Runtime Graph

Communications & Management

Interface Port(s) DB-9 RS-232, RJ-45 10/100 Base-T
Control panel Multifunction LCD status and control console
Audible Alarm Alarm when on battery : distinctive low battery alarm : configurable delays
Emergency Power Off (EPO) Yes
Available SmartSlot™ Interface Quantity 1

Physical

Maximum Height 356MM, 35.6CM
Maximum Width 483MM, 48.3CM
Maximum Depth 730MM, 73.0CM
Net Weight 74.55KG
Shipping weight 84.09KG
Shipping Height 508MM, 50.8CM
Shipping Width 584MM, 58.4CM
Shipping Depth 787MM, 78.7CM
Color Black

Environmental

Operating Temperature 0 – 40 °C
Operating Relative Humidity 0 – 95 %
Operating Elevation 0 – 3048meters
Storage Temperature -15 – 45 °C
Storage Relative Humidity 0 – 95 %
Storage Elevation 0 – 15240meters
Audible noise at 1 meter from surface of unit 60.0dBA
Online thermal dissipation 590.0BTU/hr

Conformance

Approvals C-Tick, CE, EN 50091-2, EN 60950, IRAM, VDE
Standard warranty 2 years repair or replace, optional on-site warranties available, optional extended warranties available

Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

Services Included

Silver Level

Gold Level

Platinum Level

Platinum Plus

 

Technical Hotline 24/7 Yes Yes Yes Yes Green tick
Preventative Maintenance Yes Yes Yes Yes Green tick
Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
Firmware Upgrades Yes Yes Yes Yes Green tick
Emergency Response Yes Yes Yes Yes Green tick
Labour Yes Yes Yes Yes Green tick
Parts Yes Yes Yes option Green tick
Monthly Event/Status Report option option option option Green tick
Onsite Crash Kit option option option onsite Green tick
Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
Guaranteed Fix time 4 Clock hours Green tick

3: 24×7 Remote Monitoring Contracts –

Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

Engineer Installation and configuration during normal hours Green tick
24×7 flexible status and remote monitoring. Green tick
Encrypted communication, allowing safe offsite monitoring Green tick
Alarms and events emailed and SMS texted automatically Green tick
Firewall Friendly Green tick
Cloud based status overview and multiple sites status on one screen Green tick
Allows First Fix Response to Site Green tick

4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

5. Switchgear – Contact us for more information.

Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

  • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
  • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
  • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

Customers also bought…

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us