Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988

BPC Energy PowerGem Plus RT Online Double Conversion UPS Series 1kVA - 10kVA - PGPRT

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups

    Tailor to your needs. Speak to a Specialist.
    Call: 0800 978 8988

    Purchase this item and get 0-9016 Points - equivalent to the value of £0.00-£9.02
    Purchase this item and get 0-9016 Points - equivalent to the value of £0.00-£9.02
    Product and delivery enquiries
    Call 0800 978 8988

    All major debit and credit cards accepted.

    The BPC PowerGem Plus RT is a unique range of high-density UPS systems that can be installed whether on the floor in tower form or in rackmount cabinet configurations powering a wide range of applications.

    The PowerGem is an ultra-efficient system resulting in improved operational performance up to 97% in ECO mode, 92% in inverter mode and over 90% in battery mode, providing a much greener product with smaller battery and longer autonomy backup times.

    The range is equipped with the latest digital signal processor (DSP) technology with versatile features demanded by IT managers enabling integration into all types of networking environments.

    Rack/Tower Configuration

    The PowerGem Plus RT Single Phase Uninterruptible Power Supply range is extremely versatile and designed to have the flexibility to be used as a floor-standing tower type UPS or to be integrated into the client’s 19″ rack cabinet.

    The enhanced programmable LCD display can be manually positioned to suit both modes of operation by simply removing and rotating the display panel.

    Unity Power Factor

    The PowerGem Plus RT range adopts DSP and highly efficient electronic IGBT inverter technology providing one of the highest power density ratios in the UPS industry. Advanced inverter circuitry delivers a unity power factor maximising power output.

    Programmable Frequency Converter

    The PowerGem Plus RT range may be used as a frequency converter. Simple programming through the front LCD panel will allow you to lock the output frequency at 50Hz or 60Hz to suit frequency-sensitive equipment.

    Parallel Ready N=X Redundancy

    The PowerGem Plus RT 6-10KVA models are able to be connected directly to the user’s distribution system. Models can be used in simple parallel operation with up to 4 units, allowing scalability for increased power capacity and improved reliability due to the redundancy operation. The parallel system can be connected to a common battery if required.

    • True online double conversion
    • Digital Signal Processor (DSP) technology
    • Wide input voltage (110V-300V)
    • Tower or rackmount convertible design
    • Unity output power factor (optional 0.9pf)
    • Hot swappable battery design (optional for 6-10kVA)
    • Intelligent self-diagnostics
    • Pure Sinewave output
    • Multiple communication ports
    • Emergency Power Off (EPO) function
    • Long runtime versions
    • Automatic battery test function
    • Configurable battery voltage (6-10kVA)
    • ECO mode operation for energy saving
    • Programmable frequency converter mode
    • Scalable redundancy parallel ready (6-10kVA)
    • Dust filter for hazardous environments

    Environmentally Friendly Energy Saving

    The intelligent microprocessor-based control system allows for the very low power consumption offered by the interactive ECO mode which provides efficiencies as high as 97%. PowerGem Plus RT switches instantaneously to online double conversion operation automatically when the mains become unstable and fluctuate outside the normal frequency and voltage parameters.

    Model PGPRT 1000 (L) PGPRT 2000 (L) PGPRT 3000 (L) PGPRT 6000 PGPRT 10K
    Power Rating VA / Watts 1000VA / 1000W 2000VA / 2000W 3000VA / 3000W 6kVA / 6kW 10kVA / 10kW
    Input
    Nominal Voltage 200 / 208 / 220 / 230 / 240 VAC 220 / 230 / 240 VAC
    Voltage Range 110 – 300 Vac (Load dependent) 120 – 276 Vac (Load dependent)
    Frequency Range 40 – 70Hz 42 – 55Hz at 50Hz / 54 – 66Hz at 60Hz (auto sensing)
    Power Factor >0.99 @ 100% load
    Output
    Nominal Voltage 200 / 208 / 220 / 230 / 240 Vac 220 / 230 / 240 Vac
    AC Voltage Regulation

    (Battery Mode)

    + 1%
    Frequency Range

    (Synchronised Range)

    47 – 53Hz  or 57 – 63Hz 45 – 65Hz (auto select)
    Frequency Range (Battery Mode) 50/60Hz + 0.1%Hz 50 / 60Hz + 0.1Hz
    Crest Factor 3:1
    Harmonic Distortion

    (Linear Mode)

    <3% THD
    Transfer Time Zero
    Wavefrom Pure Sinweave
    Efficiency
    AC Mode >88% >92% >92% >92.5%
    ECO Mode >95% >97% >97% >97.3%
    Battery Mode >86% >88% >90% >89% >88%
    Battery
    Battery Type VRLA AGM Sealed Lead Acid Maintenance Free Batteries
    Battery DC Voltage 24 or 36 Volts 48 Volts 72 Volts External matching battery cabinet – 192 / 216 / 240 Volts
    Typical Recharge Time 4 hours recover to 90% capacity
    Charging Current (max.)

    Standard Models

    1A 10A adjustable by LCD display
    Charging Current (max.)

    Long Runtime Models

    12A adjusted by LCD display – –
    General
    Operating Humidity 20 – 90% RH @ 0-40  (non-condensing)
    Accoustic Noise Level <50 db=”” at=”” 1=”” metre=”” –50–=””> <55 db=”” at=”” 1metre=”” –55–=””>
    Management Software Included
    Standard Model Dimensions (mm)

    W x D x H

    438 x 325 x 88 (24vdc) / 438 x 460 x 88 (36vdc option) 438 x 460 x 88 438 x 600 x 88 438 x 725 x 88

    BCRT20N009 Battery Cabinet = 438 x 585 x 133

    Standard Model Net Weight

    (kgs)

    11.3 19.1 26.2 15

    BCRT20N009 = 64

    16

    BCRT20N009 = 64

    Long Runtime Model Dimensions (mm)

    W x D x H

    438 x 305 x 88 438 x 435 x 88 – –
    Long Runtime Model Net weight

    (Kgs)

    5.6 8.3 8.6 – –

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.