    ADVANCED TOUCH SCREEN WITH LCD DISPLAY

    PowerPrime Single Phase Uninterruptible Power Supplies have an advanced colour touch screen providing precise LCD displays with real-time mimic status and parameter readings via the intelligent Digital Signal Processor (DSP) controller. Touch either of the control, measure, setting, information, or data log sub-menu icons to enter into various sub-screens.

    DUAL FEED INPUT

    The PowerPrime Dual Feed Input design increases the level of reliability and availability of the UPS system, more commonly found in larger systems. Dependability is ensured by providing from the same source a secondary path for the bypass supply to eliminate the risk of any problems with the incoming rectifier input. This superior protection allows the load to be supplied directly from the mains power source.

    MULTIPLE COMMUNICATION OPTIONS

    This feature will allow the USB or RS232 communication port to work with an SNMP simultaneously. Internal slots are provided for remote control and monitoring agents like SNMP and relay cards.

    PARALLEL READY

    The BPC philosophy is both simple and elegant. The UPS is connected directly to the user’s distribution system, eliminating the vulnerable centralised static switch and control circuits. Models can be used in simple parallel operation with up to 3 units, allowing scalability for increased power capacity and improved reliability due to the redundancy operation.

    LONGER RUNTIME APPLICATIONS

    For mission-critical applications requiring longer runtimes or higher specification batteries, the PowerPrime UPS employs an internal intelligent charging system with up to 12 amps configured by the front touch screen. Additional matching battery cabinets can easily be added and have been designed both technically and aesthetically to complement the UPS, forming a combined unit which can easily be located without the need for special site considerations.

    EXTERNAL MAINTENANCE BYPASS SWITCH CONNECTION

    The PowerPrime system has an easy connection port for direct interface to an EMBS (External Maintenance Bypass Switch). This connection allows fast communication with the internal static switch should the EMBS be closed when the UPS is operating on the Inverter. The EMBS connection provides security against the external switchgear being operated incorrectly. This feature helps to protect the UPS during all operations.

    3/1 – 1/1 INPUT CONFIGURATION

    The PowerPrime has straightforward configurable input terminal connections and is provided with multifunction jumpers to allow different variants of connections. The PowerPrime is also fitted with large connection terminals and secure gland plates to allow all types of cable installation with ease.

    SMART BATTERY MANAGEMENT

    Intelligent battery management combined with exceptional 95.5% DC/AC inverter efficiency means that PowerPrime battery sizing is optimised and greater runtimes are achieved. Maximum battery care is maintained by a three-level charging system to achieve the best performance and operating life possible. Unique self-learning function predicts more accurate backup autonomy and improves the information for the user.

    • True OnLine double conversion
    • 1/1 or 3/1 configuration
    • Advanced touch screen display
    • High AC/AC efficiency at ›96.6%
    • Intelligent event history/500 alarm logs
    • Unity output power factor
    • Wide Input Voltage (110V – 300V)
    • Smart Battery Management
    • Larger internal charger for long runtimes
    • Parallelable up to 3 units as standard
    • Standard dual feed configuration
    • Adjustable internal battery voltage
    • Digital signal (DSP) technology
    • Multiple communication ports
    • Eco mode operation for energy saving
    • Matching battery cabinets

    CONFIGURABLE BATTERY VOLTAGE

    The 20kVA version within the range has the flexibility to configure battery voltages from a ±20 block system to either ±16 or ±18 blocks depending on the application and runtime requirements.

    ENVIRONMENTALLY FRIENDLY ENERGY SAVING

    The intelligent microprocessor-based control system allows for the very low power consumption offered by the interactive ECO Mode which provides efficiencies as high as 99%. PowerPrime switches instantaneously to online double conversion operation automatically when the mains become unstable and fluctuate outside the normal frequency and voltage parameters.

    COMPACT DESIGN

    The PowerPrime system offers one of the smallest footprints available on the market, providing an exceptional power density of 112kW/m2 at 20kVA / 20kW capacity in one cabinet, for the ever-space-conscious IT Manager.

    WIDE INPUT VOLTAGE

    Part of the unique design of the PowerPrime is to improve the performance in extreme site conditions with a wide input voltage window, ranging from 110 volts up to 300 volts, without the need for the system to transfer into Battery Mode. Thus not only improving the efficiency of the system but also maximising the life of the battery.

    MODEL PPRIME 10K PPRIME 20K
    Power Rating kVA / kW 10kVA / 10kW 20kVA / 20kW
    INPUT
    Voltage Range – Low Line 110 VAC(Ph N) ±3 % at 50% Load 176 VAC(Ph N) ±3 % at 100% Load
    Voltage Range – High Line 300 VAC(Ph N) ±3 % at 50% Load 276 VAC(Ph N) ±3 % at 100% Load
    Frequency Range 46 – 54Hz at 50Hz / 56 – 64Hz at 60Hz (auto sensing)
    Phase 3 Phase with Neutral or 1 Phase with Neutral (Single or Dual Input)
    Power Factor ≥ 0.99 at 100% Load
    OUTPUT
    Phase 1 Phase with Neutral
    Nominal Output 208*/220/230/240 VAC
    AC Voltage Regulation (Battery Mode) ± 1%
    Frequency Range (Synchronised Range) 46 – 54Hz or 56 – 64Hz
    Frequency Range (Batt. Mode) 50 Hz ±0.1 Hz or 60Hz ±0.1 Hz
    Overload 100%~110%: 60min; 110%~125%: 10min; 125%~150%: 1min; ›150%
    Current Crest Ratio 3:1 max
    Harmonic Distortion ≤ 2 % @ 100% Linear Load; ≤ 5 % @ 100% Non linear Load
    Transfer Time Zero
    Output Power Factor 1.0
    EFFICIENCY
    AC Mode ›96.6%
    ECO Mode 99%
    Battery Mode ›95.5%
    BATTERY
    Battery Type VRLA AGM Sealed Lead Acid Maintenance Free Batteries
    Battery Numbers (internal) 20 (10+10) pcs (up to 2 strings internal 40 pcs) 40 (20+20) pcs
    Battery Numbers (external) 16 (8+8) to 20 (10+10) pcs 32 (16+16) to 40 (20+20) pcs
    Recharge Time 9 hours recover to 90% capacity
    Charging Current (max) 1.0 to 12.0A (Adjustable via display)
    Charging Voltage ±136.5 VDC 1% ±218 VDC 1% (32pcs) up to ±275 VDC 1% (40pcs)
    GENERAL
    Operating Temperature 0 – 40°C (the battery life will down when ›25°C)
    Operating Humidity ›95% and non-condensing
    Operating Altitude ‹1000m**
    Acoustic Noise Level ‹55dB @ 1 Metre ‹58dB @ 1 Metre
    Smart RS-232 or USB Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC
    Dimensions WxDxH (mm) 250 x 730 x 827
    Net Weight (kg) 43 44

    * Derate capacity up to 90% when the output voltage is adjusted to 208VAC.

    ** If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be Derated 1% per 100m.

    Product specifications are subject to change without further notice.

    Note for parallel operation Derate capacity to 90%

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us