    ADVANCED TOUCH SCREEN WITH LCD DISPLAY

    PowerPrime UPS have an advanced colour touch 5 inch screen providing precise LCD displays with real time mimic status and parameter readings via the intelligent Digital Signal Processor (DSP) controller. Touch either of the control, measure, setting, information or data log sub menu icons to enter into various sub screens.

    DUAL FEED INPUT (UP TO 40KVA)

    The PowerPrime Dual Feed Input design increases the levels of reliability and availability of the UPS system which is more commonly found in larger systems. Dependability is ensured by providing from the same source a secondary path for the bypass supply to eliminate the risk of any problems with the incoming rectifier input. This superior protection allows the load to be supplied directly from the mains power source.

    MULTIPLE COMMUNICATION OPTIONS

    The USB communication port can be used to locally monitor the UPS system. Internal slot is provided for SNMP communication.
    8 output dry ports and 6 input dry ports are provided as standard to allow further communication with UPS.

    PARALLEL READY

    The BPC philosophy is both simple and elegant with each model provided parallel ready. The UPS can be connected together without any requirement to install further control circuits into the UPS system. BPC would always recommend installing one of our parallel switch panels to provide correct cable protection and aid all ongoing maintenance. Models can be used in simple parallel operation with up to 4 units, allowing scalability for increased power capacity and improved reliability due to the redundancy operation.

    LONGER RUNTIME APPLICATIONS

    For mission critical applications requiring longer runtimes or higher specification batteries, PowerPrime UPS employ an internal intelligent charging system with up to 12 Amps (18A on 60kVA model) configured by the front touch screen. Additional matching battery cabinets can easily be added and have been designed both technically and aesthetically to complement the UPS, forming a combined unit which can be easily positioned.

    EXTERNAL MAINTENANCE BYPASS SWITCH CONNECTION

    The PowerPrime system has an easy connection port for direct interface to an EMBS (External Maintenance Bypass Switch). This connection allows a fast communication with the internal static switch should the EMBS be closed when the UPS is operating on inverter. The EMBS connection provides security against the external switchgear being operated incorrectly. This feature helps to protect the UPS during all operations.

    INPUT CONFIGURATION

    The PowerPrime 10kVA and 20kVA single phase output models have configurable input terminal connections and is provided with multifunctional jumpers to allow either single phase or three phase input connections. All PowerPrime models are fitted with large connection terminals and secure gland plates to allow secure cable connection to the UPS.

    SMART BATTERY MANAGEMENT

    Intelligent battery management combined with exceptional 95.5% DC/AC inverter efficiency means that PowerPrime battery sizing is optimised and greater runtimes are achieved. Maximum battery care is maintained by a three level charging system to achieve the best performance and operating life possible. Unique self learning function predicts more accurate backup autonomy and improves the information for the user.

    • True On Line Double Conversion
    • 1/1, 1/3, 3/3 configuration depending on model
    • Advanced touch screen display
    • High AC/AC efficiency up to 96.6%
    • Intelligent event history / 500 alarm logs
    • Unity output power factor
    • Wide input voltage (100V 300V)
    • Smart battery management
    • Larger internal charger for long runtimes
    • Parallelable up to 4 units as standard
    • Standard dual feed configuration
    • Adjustable internal battery voltage
    • Digital signal (DSP) technology
    • Multiple communication ports
    • ECO mode operation for energy saving
    • Matching battery cabinets

    CONFIGURABLE BATTERY VOLTAGE

    The 20kVA models and above have the flexibility to configure battery voltages. Internal battery options usually have either 32 (16+16) pcs or 40 (20+20) pcs that can be configured with matching battery cabinets. Depending on application and runtime requirements, external batteries can be configured with battery variations from 32 (16+16) pcs to 40 (20+20) pcs.

    COMPACT DESIGN

    The PowerPrime system offers one of the smallest footprints available on the market, providing exceptional power density of 156KW/m³ at 40kVA/40kW capacity with battery in one cabinet, for the ever space conscious IT manager.

    WIDE INPUT VOLTAGE

    Part of the unique design of the PowerPrime is to improve the performance in extreme site conditions with a wide input voltage window, ranging from 110 Volts up to 300 Volts, without the need for the system to transfer into Battery Mode, thus not only improving the efficiency of the system, but also maximising the life of the battery.

    MODEL PPRIME310 PPRIME320 PPRIME330 PPRIME340 PPRIME360
    Power Rating kVA/kW 10kVA/10kW 20kVA/20kW 30kVA/30kW 40kVA/40kW 60kVA/60kW
    INPUT
    Nominal Voltage 3 x 380/400/415VAC (3PH+N)
    Voltage Range – Low Line 110 VAC(PH+N) ±3% at 50% load 176 VAC (PH+N) ±3% at 100% load
    Voltage Range – High Line 300 VAC(PH+N) ±3% at 50% load 276 VAC (PH+N) ±3% at 100% load
    Frequency Range 46-54Hz at 50Hz / 56-64Hz at 60Hz (auto sensing)
    Phase 3 Phase with Neutral
    Power Factor ≥ 0.99 at 100% Load
    OUTPUT
    Phase 3 Phase with Neutral
    Nominal Output 380/400/415 VAC (Ph-Ph) and 220/230/240 VAC (Ph+N)
    AC Voltage Regulation (Battery Mode) ±1%
    Frequency Range (Synchronised Range) 46-54Hz or 56-64Hz
    Frequency Range (Battery Mode) 50Hz ±0.1Hz or 60Hz ±0.1Hz
    Overload 100%-110%: 60 mins; 110%-125%: 10mins; 125%-150%: 1 min; >150% : 400ms
    Current Crest Factor 3:1 max
    Harmonic Distortion ≤2% @ 100% Linear Load ; ≤5% @ 100% Non Linear Load
    Transfer Time Zero
    Output Power Factor 1
    EFFICIENCY
    AC Mode ›95.5%
    ECO Mode 98.5%
    Battery Mode ›94.5%
    BATTERY
    Battery Type VRLA AGM Sealed Lead Acid Maintenance Free Batteries
    Battery Numbers (internal) 20 (10+10) pcs
    (up to 2 strings 40pcs)
    40 (20 + 20) pcs 32 (16 + 16) pcs External batteries only
    Battery Numbers (external) 16 (8+8) to 20 (10+10) pcs 32 (16 + 16) to 40 (20+20) pcs
    Recharge Time 9 hours recover to 90% capacity
    Charging Current (Max.) 1 to 12A (adjustable via the display) 18A
    Nominal Charging Voltage*** ±136.5 VDC 1% ±273 VDC ±1% ±218 VDC ±1% ±273 VDC ±1%
    GENERAL
    Operating Temperature 0-40°C (the battery life will be effected above 25°C)
    Operating Humidity ›95% and non-condensing
    Operating Altitude <1000m**
    Acoustic Noise Level <55db 1=”” metre=”” –55db–=””> <58db 1=”” metre=”” –58db–=””> <65db 1=”” metre=”” –65db–=””> <65db 1=”” metre=”” td=””> <70db 1=”” metre=”” td=””>
    Smart RS232 or USB Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC
    Dimensions (WxDxH) 250 x 730 x 827 300 x 815 x 1007 300 x 945 x 1007
    Net Weight (kg) 46 47 56 60 74

    ** If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be Derated 1% per 100m.

    *** Nominal Charge Voltage is for internal battery options. For external battery charge voltage, see user manual

    Product specifications are subject to change without further notice.

    Note for parallel operation Derate capacity to 90%

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.