Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988

BPC Energy PowerStar i Series, Simulated Sinewave UPS, 600VA - 2000VA - PSTARi

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups

    Tailor to your needs. Speak to a Specialist.
    Call: 0800 978 8988

    Purchase this item and get 0-1444 Points - equivalent to the value of £0.00-£1.44
    Purchase this item and get 0-1444 Points - equivalent to the value of £0.00-£1.44
    Product and delivery enquiries
    Call 0800 978 8988

    All major debit and credit cards accepted.

    BPC have a range of intelligent Line Interactive UPS products, designed to offer total power protection to a broad range of applications.

    The PowerStar i Series range will provide clean and reliable backup power to ensure continued data integrity and optimum performance under a wide range of mains power conditions to offer total power protection to a broad range of modest applications.

    The PowerStar i Series range of Single Phase Uninterruptible Power Supplies will provide clean and reliable backup power to ensure continued data integrity and optimum performance under a wide range of mains power conditions to offer total power protection to a broad range of modest applications.

    This high level of power protection can be incorporated with our advanced power management and diagnostics software package that will allow your IT Manager or Systems Integrator to remotely monitor and manage both the UPS and IT application.

    • Fully intelligent line interactive
    • Microprocessor based design
    • LCD touch screen user interface
    • Boost and buck AVR for voltage stabilisation
    • Cold start function
    • Built in USB communication port
    • Overload protection
    • Intelligent power management
    • Compact size
    Power Rating VA / Watts 600 / 360 800 / 480 1000 / 600 1500 / 900 2000 / 1200
    INPUT
    Nominal Voltage 220 Vac / 230 Vac / 240 Vac
    Voltage Range 162 – 290 Vac
    Frequency 50 or 60 Hz (auto-sensing)
    OUTPUT
    Nominl Voltage 220 Vac / 230 Vac / 240 Vac
    Frequency ±1 Hz
    Transfer Time Typical 2-6ms
    Overload Capacity (online) 110% ±10% (Fault alarm after 5 minutes), 120% ±10% (shutdown immediately)
    BATTERY
    Battery Type VRLA AGM Sealed Lead Acid Maintenance Free Batteries
    Charging Current (max.) Approximately 1A
    Charging Voltage 13.7 ±0.5V (normal mode)
    GENERAL
    Temperature / Humidity 0 – 40˚C / 0 – 90% (non-condensing)
    Acoustic Noise Level Less than 40dB
    Management Software Included
    Dimensions (mm) WxDxH 101 x 300 x 142 130 x 300 x 182
    Net Weight (kg) 4.4 5 8.2 10.4 11

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us