Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988

CyberPower CP1200EIPFCRM2U uninterruptible power supply (UPS) Line-Interactive 1.2kVA 720W 8 AC outlet(s)

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups

    £292.01 Ex VAT
    £350.41 Inc VAT

    Delivery Costs

    Find below some of our pricing costs for Critical Power Supplies online store.

    England, Wales and Scottish Lowlands

    2 to 3 Working Days - £4.99.
    Next Working Day - £9.99.
    Pre Noon, Pre 10:30am - Contact Us.

    Scottish Lowlands Postcodes
    AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9

    Highlands, Northern Ireland, Channel Islands and Ireland

    • Scottish Highlands
      3 to 5 Working Days - £20

      Scottish Highlands Postcodes
      AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4

    • Northern Ireland
      3 to 5 Working Days - £50

    • Channel Islands
      3 to 5 Working Days - £25

    • Ireland
      5 to 7 Working Days - £99

    • Western Europe
      5 to 7 Working Days - £150 DAP
      DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.

    Available to orderAvailability and estimated dispatch date confirmed after ordering.

    Purchase this item and get 2920 Points - equivalent to the value of £2.92

    Standard parcel delivery
    Next Day — £12.95 ex VAT
    2-3 Days — £6.95 ex VAT
    3-5 Days — Free on eligible orders of £350 ex VAT (£420 inc VAT) or more, after discounts
    Available on eligible orders and delivery postcodes. Delivery options confirmed at checkout.

    Need help or a delivery date?

    All major debit and credit cards accepted.

    CyberPower CP1200EIPFCRM2U  with seamless Pure Sine Wave output provides complete protection for networking devices, security systems, and other electronic devices requiring active PFC power supply. Built in Automatic Voltage Regulation (AVR) function, this Line-Interactive UPS offers stabilized power output to connected devices. In addition, the UPS adopts CyberPower’s patented GreenPower UPS™ technology, which greatly reduces UPS energy consumption and enhances its operating efficiency. The featured data line protection with high-speed transmission safeguards networking devices against surges and spikes while supporting data transmission speed up to 1Gbps. With short-depth chassis design, the UPS significantly optimizes space in a rack enclosure and can meet different space requirements. Besides, the UPS is designed with a color LCD panel for users to quickly confirm the status and monitor the power system. This product also allows users to perform remote management of the UPS via PowerPanel Management Software.

    Features

    • Line-interactive UPS Topology
    • Active PFC Compatible
    • Automatic Voltage Regulation (AVR)
    • Critical/Non-critical Load Outlets
    • Color LCD Panel
    • USB Connectivity Port
    • PowerPanel Management Software
    • Surge and Spike Protection
    • Network Protection
    • Energy Saving Technology
    • Pure Sine Wave Output
    • Overload Protection
    • Hot-swappable Batteries
    • LED Status Indicator
    • High-speed Ethernet Data Transmission
    • SNMP/HTTP Remote Management Capability (Optional)
    • EMI and RFI Filtration
    • Short-depth Chassis Design

    Shipped with the product in the box

    • CP1200EIPFCRM2U UPS
    • Rackmount Ears
    • Power Cord
    • USB Cable
    • User’s Manual
    • Function Setup Guide

    * Product contents may vary according to different regions. For detailed information, please refer to user’s manual/quick start guide

    General

    Phase

    Single Phase

    Form Factor

    Rackmount

    UPS Topology

    Line-interactive

    Energy Saving Technology

    GreenPower UPS™ Bypass Technology

    Active PFC Compatibility

    Yes

    Input

    Nominal Input Voltage ( Vac )

    230

    Input Voltage Range ( Vac )

    169 ~ 271

    Input Frequency ( Hz )

    60 ± 3
    50 ± 3

    Input Frequency Detection

    Auto-sensing

    Rated Input Current ( A )

    10

    Input Connector Type

    IEC C14  

    Detachable Power Cord Plug Type

    IEC C14 x 1  

    Power Cord Length (ft.)

    6

    Power Cord Length (m.)

    1.8

    Output

    Capacity (VA)

    1200

    Capacity (Watts)

    720

    On Battery Waveform

    Pure Sine Wave

    On Battery Voltage(s) ( Vac )

    230 ± 5%(Under a test load of<60%. When the load>60%, the output voltage range may>5%.)

    On Battery Frequency ( Hz )

    60 ± 1%
    50 ± 1%

    Power Factor

    0.6

    Automatic Voltage Regulation (AVR)

    Single Boost

    Overload Protection

    Internal Current Limiting, Circuit Breaker

    Outlet(s) – Total

    8

    Outlet Type

    IEC C13 x 8  

    Outlet(s) – Battery & Surge Protected

    8

    Outlet(s) – Surge-Only Protected

    0

    Outlet(s) – Widely Spaced

    0

    Outlet(s) – Critical Load (CL)

    4

    Outlet(s) – Non-critical Load (NCL)

    4

    Battery

    Runtime at Half Load ( min )

    11.6

    Runtime at Full Load ( min )

    3.4

    Typical Recharge Time ( Hours )

    8(Recover to 90% after full load discharge)

    User-replaceable

    Yes

    Hot-swappable

    Yes

    Battery Type

    Sealed Lead-acid

    Replacement Battery Pack (RBP)

    RBP0181

    Replacement Battery Pack (RBP) Quantity ( pcs )

    1

    Surge Protection & Filtering

    Surge Suppression ( Joules )

    900

    EMI/RFI Filtration

    Yes

    Network Protection RJ45

    1-in, 1-out

    Management & Communications

    LCD Panel

    Yes

    LCD Types

    Color LCD

    LCD Information Display

    Power Status, Battery Status, Load Status, Fault & Warning

    LCD Setting & Control

    Alarm Setting, Input & Output

    LED Indicators

    Power On

    HID Compliant USB Port(s)

    1

    Audible Alarms

    Battery Mode, Low Battery, Overload, UPS Fault

    Management Cable ( pcs )

    Power Cord x1, USB Cable x1

    Ethernet Data Transmission Speed

    Up to 1Gbps

    Power Management Software

    PowerPanel Business (Recommended)

    SNMP/HTTP Remote Monitoring

    Yes – with optional RMCARD205

    PowerPanel Cloud Service

    Yes – 90 Days Free Trial with PowerPanel Personal/Business

    Physical

    Enclosure Construction

    Plastic

    Color

    Black

    Rackmount Ears

    Yes

    Physical Size – UPS Module

    Dimensions (WxHxD) (mm.)

    433 x 86 x 274

    Weight (kg.)

    11.59

    Shipping Dimensions

    Dimensions (WxHxD) (mm.)

    523 x 162 x 374

    Weight (kg.)

    12.86

    Environmental

    Operating Temperature (°F)

    32 ~ 104

    Operating Temperature (°C)

    0 ~ 40

    Operating Relative Humidity (Non-condensing) ( % )

    0 ~ 95

    Operating Elevation ( feet/meters )

    0-9,843 feet (0-3,000 meters)

    Storage Temperature (°F)

    5 ~ 113

    Storage Temperature (°C)

    -15 ~ 45

    Storage Relative Humidity (Non-condensing) ( % )

    0 ~ 95

    Storage Elevation ( feet/meters )

    0-49,213 feet (0-15,000 meters)

    Online Thermal Dissipation ( BTU/hr )

    17.1

    Certifications

    Certifications

    CE

    RoHS

    Yes

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us