Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988
SKU: OL6KERTHD Categories: , Brand: Cyberpower Tag:

Cyberpower Online (High-Density) 6kVA Online 230V (UPS) (2U) - OL6KERTHD

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups

    £3304.12 Ex VAT
    £3964.94 Inc VAT

    Delivery Costs

    Find below some of our pricing costs for Critical Power Supplies online store.

    England, Wales and Scottish Lowlands

    2 to 3 Working Days - £4.99.
    Next Working Day - £9.99.
    Pre Noon, Pre 10:30am - Contact Us.

    Scottish Lowlands Postcodes
    AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9

    Highlands, Northern Ireland, Channel Islands and Ireland

    • Scottish Highlands
      3 to 5 Working Days - £20

      Scottish Highlands Postcodes
      AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4

    • Northern Ireland
      3 to 5 Working Days - £50

    • Channel Islands
      3 to 5 Working Days - £25

    • Ireland
      5 to 7 Working Days - £99

    • Western Europe
      5 to 7 Working Days - £150 DAP
      DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.

    Purchase this item and get 33041 Points - equivalent to the value of £33.04

    In Stock — 1 available to order

    Delivery
    Delivery options, charges and estimated delivery times are shown at checkout.
    Need this urgently? Contact Sales to confirm availability and delivery options.
    Call 0800 978 8988

    All major debit and credit cards accepted.

    CyberPower OL6KERTHD

    guarantees power backup protection for IT equipment, servers, workstations, NAS/Storage devices, telecom devices, networking devices, security/emergency systems, and surveillance systems. The UPS adopts double-conversion topology to provide high-quality power output in a compact design. This generator-compatible UPS features hot-swappable battery packs for maintenance without power interruption, and comes with additional ECO Mode to conserve power and save on energy costs.

    The UPS can employ Extended Battery Modules (EBM) to prolong runtimes, and adopts patented Battery Management Technology to balance battery string voltage for optimal battery lifespan. This model also features tiltable color LCD panel that allows users to monitor key power and battery information at a glance. The PowerPanel® Power Management Software allows user to perform real-time monitoring and remote management of the UPS.

    Features

    • Online (Double Conversion) UPS Topology
    • High Density Design
    • High Output Power Factor
    • Tiltable LCD Panel
    • Surge and Spike Protection
    • Generator Compatible
    • Hot-swappable Batteries
    • Smart Battery Management (SBM)
    • SNMP/HTTP Remote Management Capability
    • ECO Mode
    • Color LCD Panel
    • Quick Charging Technology
    • Automatically rotatable LCD
    • Critical/Non-critical Load Outlets
    • Battery Management Technology
    • Extended Battery Module (EBM)
    • Emergency Power Off (EPO) Port
    • PowerPanel® Management Software

    What’s in the box

    • OL6KERTHD
      UPS
    • Rackmount Rail
    • Rackmount Ears
    • Terminal Cover
    • Screw Kit
    • USB Cable
    • Serial Cable
    • User’s Manual

    *
    Product contents may vary according to different regions.
    For detailed information, please refer to user’s manual/quick start guide.

    General
    UPS Topology Online Double Conversion
    Energy Saving Technology Online ECO Mode Eciency > 96%
    Active PFC Compatibility Yes
    Input
    Generator Compatibility Yes
    Nominal Input Voltage (Vac) 200 ± 2%, 208 ± 2%, 220 ± 2%, 230 ± 2%, 240 ± 2%
    Input Voltage Range (Vac) 180 ~ 280
    Input Frequency (Hz) 50 ± 10, 60 ± 10
    Input Frequency Detection Auto-sensing
    Rated Input Current (A) 32
    Input Power Factor 0.99
    Input Connector Type Hardwire Terminal Block
    Output
    Capacity (VA) 6000
    Capacity (Watts) 6000
    On Battery Waveform Pure Sine Wave
    On Battery Voltage(s) (Vac) 200 ± 2%, 208 ± 2%, 220 ± 2%, 230 ± 2%, 240 ± 2%
    Output Voltage Setting Configurable
    On Battery Frequency (Hz) 50 ± 0.5%, 60 ± 0.5%
    Output Frequency Setting Configurable
    Power Factor 1
    Overload Protection Internal Current Limiting, Circuit Breaker, Fuse
    Overload Protection (Line Mode) 105~125% Load for 1 min, 125~150% Load for 10 sec
    Overload Protection (Battery Mode) 105~130% Load for 10 sec, 130~150% Load for 2 sec
    Overload Protection (Bypass Mode) Circuit Breaker
    Harmonic Distortion (Linear Load) THD<3%
    Harmonic Distortion (Non-linear Load) THD<5%
    Outlet(s) – Total 7
    Outlet Type IEC C19 x 2, IEC C13 x 4, Hardwire Terminal Block x 1
    Outlet(s) – Battery & Surge Protected 7
    Outlet(s) – Critical Load (CL) 4
    Outlet(s) – Non-Critical Load (NCL) 3
    Typical Transfer Time (ms) 0
    Battery
    Runtime at Half Load (min) 4.9
    Runtime at Full Load (min) 1.4
    Typical Recharge Time (Hours) 4
    Smart Battery Management (SBM) Yes
    User-replaceable Yes – Qualified Personnel Only
    Hot-swappable Yes
    Battery Type Sealed Lead-acid
    Replacement Battery Pack RBP0144
    RBP Quantity (pcs) 1
    Extended Battery Module (EBM) BPE144VL2U01 (Built-in Charger)
    Max. EBM Quantity (pcs) 10
    Surge Protection & Filtering
    Surge Suppression (Joules) 2430
    EMI/RFI Filtration Yes
    Management & Communications
    LCD Panel Yes
    LCD Orientation Automatic LCD screen orientation, Rotatable LCD panel
    HID Compliant USB Port(s) 1
    Serial Port Combo (RS232 + Dry Contact)
    Emergency Power O(EPO) Port Yes
    Power Management Software PowerPanel® Business
    SNMP/HTTP Remote Monitoring Yes – Pre-installed
    Physical
    Form Factor Rack/Tower
    Physical Size – UPS Module
    Dimensions (WxHxD) (mm.) 433 x 86.5 x 720
    Weight (kg.) 42
    Installed Rack Height (U) 2
    Environmental
    Operating Temperature (°C) 0 ~ 40
    Operating Relative Humidity
    (Non-condensing) (%)
    0 ~ 90
    Online Thermal Dissipation (BTU/hr) 1613
    Certifications
    Certifications* CE, EAC, RCM
    RoHS Yes

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us