Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988
SKU: OLS3000E Categories: , Brand: Cyberpower Tag:

CyberPower Online S Range 3kVA Online 230V (UPS) - OLS3000E

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups

    Tailor to your needs. Speak to a Specialist.
    Call: 0800 978 8988

    Product and delivery enquiries
    Call 0800 978 8988

    CyberPower OLS3000E

    is a high-performance UPS featuring online double-conversion topology, which provides seamless Pure Sine Wave power for mission-critical devices such as NAS and servers, DVRs/surveillance systems, transportation and infrastructure, and emergency systems. It’s typically integrated in the back office, server room, and data center environment.

    Features

    • Online (Double Conversion) UPS Topology
    • Generator Compatible
    • Zero Transfer Time
    • Extended Battery Module (EBM)
    • EMI and RFI Filtration
    • LCD Status Display
    • PowerPanel® Management Software
    • ECO Mode
    • Overload Protection
    • Smart Battery Management (SBM)
    • Surge and Spike Protection
    • Phone/Fax/Modem/DSL/Network Protection
    • Emergency Power Off (EPO) Port
    • SNMP/HTTP Remote Management Capability (Optional)

    What’s in the box

    • OLS3000E
      UPS
    • Power Cord
    • USB Cable
    • Phone Line
    • User’s Manual

    *
    Product contents may vary according to different regions.
    For detailed information, please refer to user’s manual/quick start guide.

    Model Name OLS1000E OLS1500E OLS2000E OLS3000E
    General
    UPS Topology Online Double Conversion Online Double Conversion Online Double Conversion Online Double Conversion
    Energy Saving Technology Online ECO Mode Eciency > 95% Online ECO Mode Eciency > 95% Online ECO Mode Eciency > 95% Online ECO Mode Eciency > 95%
    Active PFC Compatibility Yes Yes Yes Yes
    Input
    Generator Compatibility Yes Yes Yes Yes
    Nominal Input Voltage (Vac) 230 ± 10% 230 ± 10% 230 ± 10% 230 ± 10%
    Input Voltage Range (Vac) 160 ~ 300 160 ~ 300 160 ~ 300 190 ~ 300
    Input Frequency (Hz) 50 ± 10, 60 ± 10 50 ± 10, 60 ± 10 50 ± 10, 60 ± 10 50 ± 10, 60 ± 10
    Input Frequency Detection Auto-sensing Auto-sensing Auto-sensing Auto-sensing
    Rated Input Current (A) 4.5 6.5 9 13.04
    Input Power Factor 0.98 0.98 0.98 0.98
    Input Connector Type IEC C14 IEC C14 IEC C20 IEC C20
    Output
    Capacity (VA) 1000 1500 2000 3000
    Capacity (Watts) 900 1350 1800 2700
    On Battery Waveform Pure Sine Wave Pure Sine Wave Pure Sine Wave Pure Sine Wave
    On Battery Voltage(s) (Vac) 208 ± 1%, 220 ± 1%, 230 ± 1%, 240 ± 1%
    Output Voltage Setting Configurable Configurable Configurable Configurable
    On Battery Frequency (Hz) 50 ± 0.5%, 60 ± 0.5% 50 ± 0.5%, 60 ± 0.5% 50 ± 0.5%, 60 ± 0.5% 50 ± 0.5%, 60 ± 0.5%
    Output Frequency Setting Configurable Configurable Configurable Configurable
    Power Factor 0.9 0.9 0.9 0.9
    Overload Protection Internal Current Limiting, Circuit Breaker, Fuse
    Overload Protection (Line Mode) 110~120% Load for 1 min, >120% Load Immediately
    Overload Protection (Battery Mode) 110~120% Load for 10 sec, >120% Load Immediately
    Overload Protection (Bypass Mode) >130% Load Immediately >130% Load Immediately >130% Load Immediately >130% Load Immediately
    Harmonic Distortion (Linear Load) THD<3% THD<3% THD<3% THD<3%
    Harmonic Distortion (Non-linear Load) THD<5% THD<5% THD<5% THD<5%
    Outlet(s) – Total 4 4 5 6
    Outlet Type IEC C13 x 4 IEC C13 x 4 Hardwire Terminal Block x 1,
    IEC C13 x 4
    IEC C19 x 1, Hardwire Terminal Block x 1,
    IEC C13 x 4
    Outlet(s) – Battery & Surge Protected 4 4 4 5
    Typical Transfer Time (ms) 0 0 0 0
    Battery
    Runtime at Half Load (min) 15 14 15 14
    Runtime at Full Load (min) 5 4 5 4
    Typical Recharge Time (Hours) 5 5 5 5
    Smart Battery Management (SBM) Yes Yes Yes Yes
    User Replaceable No No No No
    Battery Type Sealed Lead-acid Sealed Lead-acid Sealed Lead-acid Sealed Lead-acid
    Extended Battery Module (EBM) BPSE36V45A BPSE36V45A BPSE72V45A BPSE72V45A
    Max. EBM Quantity (pcs) 3 3 3 3
    Surge Protection & Filtering
    Surge Suppression (Joules) 440 440 440 440
    EMI/RFI Filtration Yes Yes Yes Yes
    Phone/Network Protection RJ11/RJ45 (Combo) 1-in, 1-out 1-in, 1-out 1-in, 1-out 1-in, 1-out
    Management & Communications
    LCD Panel Yes Yes Yes Yes
    HID Compliant USB Port(s) 1 1 1 1
    Serial Port RS232 RS232 RS232 RS232
    Emergency Power O(EPO) Port Yes Yes Yes Yes
    Power Management Software PowerPanel® Business PowerPanel® Business PowerPanel® Business PowerPanel® Business
    SNMP/HTTP Remote Monitoring Yes – with optional RMCARD205 Yes – with optional RMCARD205 Yes – with optional RMCARD205 Yes – with optional RMCARD205
    Physical
    Form Factor Tower Tower Tower Tower
    Physical Size – UPS Module
    Dimensions (WxHxD) (mm.) 151 x 225 x 394 151 x 225 x 394 196 x 337 x 416 196 x 337 x 416
    Weight (kg.) 13.1 15.3 23.8 28.2
    Environmental
    Operating Temperature (°C) 0 ~ 40 0 ~ 40 0 ~ 40 0 ~ 40
    Operating Relative Humidity (Non-condensing) (%) 20 ~ 90 20 ~ 90 20 ~ 90 20 ~ 90
    Online Thermal Dissipation (BTU/hr) 342 420 666 1126
    Certifications
    Certifications* CE, EAC, LOA, RCM, BIS CE, EAC, LOA, RCM, BIS CE, EAC, LOA, RCM, BIS CE, EAC, LOA, RCM, BIS
    RoHS Yes Yes Yes Yes

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us