SKU: E3SUPS10K3IB1 Categories: , , , , Tag:

APC Easy UPS 3S 10 kVA 400V 3:1 UPS, 1 internal 7Ah modular battery string, expandable to 3 - E3SUPS10K3IB1

£4,977.88 Ex. VAT £5,973.46 Inc. VAT

Warranty: 1 Year

All major debit and credit cards accepted.

  • Description

    Easy UPS 3S Features & Benefits

    Convenience

    Easy Loop Test Verifies UPS performance before you connect your load, without the need for a load bank.

    Front-access servicing Simplifies installation and UPS maintenance while minimizing space requirements.

    ECO Mode Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection

    Straightforward installation Including the input, output, and bypass breakers, as well as the Emergency Power Off (EPO) switch, simplifies installation planning and speeds up deployment.

    Easy to install fast Quickly roll the compact and lightweight UPS into position.

    Intuitive user interface The intuitive graphical user interface allows for easy system configuration.

    Protection

    Wide Input Voltage Window Saves your battery power for when you really need it – during power cuts!

    Replaceable dust filters protect the UPS in harsh environments.

    Parallel capability Multiple units can be placed in parallel to meet power capacity and redundancy requirements

    Optional SNMP Card When you purchase the SNMP card, you can monitor and manage UPS status remotely through the UPS Web interface or through EcoStruxure IT’s cloud-based and on-premise software suites. Click here for more information about EcoStruxure IT.

  • Technical Data

    Output

    Max Configurable Power (Watts) 10.0kWatts
    / 10.0kVA
    Output Voltage Distortion Less than 3 %
    Output Frequency (sync to mains) 50 Hz Sync to mains, 60 Hz Sync to mains
    Other Output Voltages 220 V, 240 V
    Load Crest Factor 3 : 1
    Topology Double conversion online
    Overload Operation 10 minutes at 125% and 60 seconds at 150%
    Output Voltage THD < 5.5% at 100% non-linear load
    Output Voltage Tolerance +/- 1.5 %

    Input

    Input frequency 45 – 65 Hz
    Input voltage range for main operations 304 – 477V
    Input Total Harmonic Distortion Less than 4 % for full load
    Other Input Voltages 380 V, 415 V
    Input Power Factor at Full Load 0.99

    Batteries & Runtime

    Battery type VRLA
    Included Battery Modules 1
    Nominal Battery Voltage 240 V
    Battery Slots Empty 2
    Replacement battery cartridge note UPS weight does not include battery weight.
    End of Discharge Battery Voltage +/- 198 V DC
    Maximum Available Short Circuit Current 10kAmps
    Efficiency View Here
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

  • Downloads
  • Reviews (0)
    Product Reviews

    Reviews

    There are no reviews yet.

    Be the first to review “APC Easy UPS 3S 10 kVA 400V 3:1 UPS, 1 internal 7Ah modular battery string, expandable to 3”

    Your email address will not be published.

    Company Reviews

Customers also bought…

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us