    The new Eaton 5P is the next generation of 650VA-1550VA line-Interactive UPS with advanced LCD and energy metering feature. 5P is the perfect UPS to protect IT & networking devices such as servers, switches, routers and storage devices, in tower or rack format.

    Graphical LCD

    The new graphical LCD display provides clear information on he UPS’s status and measurements on a single screen (in seven languages). Enhanced configuration capabilities are also available with easy-to-use navigation keys.

    Energy efficient

    With an optimised electrical design, the 5P provides up to 98% efficiency, reducing cooling and utility costs. The 5P can also meter energy consumption providing kWh values through the LCD and Eaton’s power management software.

    Virtualisation-ready

    With an optional network card and Eaton’s Intelligent Power® Software Suite compatible with all major OS 5P seamlessly integrates into virtualisation software such as VMware and Hyper-V.

    General specifications

    Product Name Eaton 5P UPS
    Catalog Number 5P1550I
    Model Code Eaton 5P 1550i
    UPC 743172042859
    Product Length/Depth 445 mm
    Product Height 230 mm
    Product Width 150 mm
    Product Weight 15.6 kg
    Warranty 3 year on electronics, 3 year on batteries with registration
    Compliances CE Marked
    TUV
    Certifications UL 1778
    IEC/EN 62040-1
    IEC/EN 62040-2
    CE
    EAC
    cTUVus
    Model Code Eaton 5P 1550i

    Product specifications

    Secondary frequency – max 60 Hz
    Output waveform Sine wave
    Wattage 1100 W
    Output power factor 0.7
    Form factor Tower
    Enclosure Black/silver
    Includes network card No
    Input connection C14
    Input voltage – min 150 V
    Output voltage – max 240 V
    Secondary frequency – min 50 Hz
    Software compatibility Eaton Intelligent Power Manager, Eaton Intelligent Power Protector
    Battery replacement User replaceable
    Battery type Lead-acid maintenance-free (replaceable)
    Efficiency 97
    Special features Automatic Voltage Regulation (AVR)|Energy efficient, reduce energy and cooling costs|Delivers clean sinewave output|1 slot for optional com card (Network management card, Relay card or Network and Industrial card)|Compatible with Virtual environments (VMware, Hyper-V, Citrix Xen, Redhat)|Fully integrates with Eaton Intelligent Power Manager software|1 USB port + 1 serial port|Advanced Battery Management (ABM) technology to increase battery lifetime|Next-generation graphical LCD display|Hot swappable batteries|Remote reboot and runtime optimization thanks to 2 manageable outlet groups|Remote ON/OFF and remote Power OFF connectors
    Construction type Free standing model
    Output voltage – min 200 V
    Color Black/silver
    Extended battery capability No
    Output voltage range 230 V (+6%/-10%)
    Topology Line-interactive
    BTU Rating Online: 225
    Back-up time 4 min
    Input nominal voltage 230V default (200/208/220/230/240V)
    Input frequency range 47-70 Hz (50 Hz system), 56.5-70 Hz (60 Hz system), 40 Hz in low sensitivity mode
    Input voltage – max 294 V
    Voltage type AC
    Phase (output) 1
    Battery management

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us