Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988

Eaton 9SX 96V Battery Extension Pack (For use with 9SX2000I and 9SX3000I) - 38ca89564b22

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups

    £666.12 Ex VAT
    £799.34 Inc VAT

    Delivery Costs

    Find below some of our pricing costs for Critical Power Supplies online store.

    England, Wales and Scottish Lowlands

    2 to 3 Working Days - £4.99.
    Next Working Day - £9.99.
    Pre Noon, Pre 10:30am - Contact Us.

    Scottish Lowlands Postcodes
    AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9

    Highlands, Northern Ireland, Channel Islands and Ireland

    • Scottish Highlands
      3 to 5 Working Days - £20

      Scottish Highlands Postcodes
      AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4

    • Northern Ireland
      3 to 5 Working Days - £50

    • Channel Islands
      3 to 5 Working Days - £25

    • Ireland
      5 to 7 Working Days - £99

    • Western Europe
      5 to 7 Working Days - £150 DAP
      DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.

    Purchase this item and get 6661 Points - equivalent to the value of £6.66

    In Stock — 7 available to order

    Delivery
    Delivery options, charges and estimated delivery times are shown at checkout.
    Need this urgently? Contact Sales to confirm availability and delivery options.
    Call 0800 978 8988

    All major debit and credit cards accepted.

    Eaton 9SX 96V Battery Extension Pack (For use with 9SX2000I and 9SX3000I)

    The Eaton battery extension pack is a great addition to your 9SX2000I or the 9SX3000I unit to extend the runtime of your UPS so that it will allow you to keep on running during a power outage for longer and not lose any critical data.

    The 9SX EBMs have an innovative battery management technology that uses a three-stage charging technique that extends the battery life by up to 50%.

    This battery extension pack can offer up to 40 minutes with 1 EBM at full load, 77 minutes with 2 EBMs at full load, 116 minutes with 3 EBMs at full load and 160 minutes with the max of 4 EBMs at full load on the 9SX2000I. This pack can also offer up to 29 minutes with 1 EBM at full load, 52 minutes with 2 EBMs at full load, 79 minutes with 3 EBMs at full load and 106 minutes with the max of 4 EBMs at full load on the 9SX3000I

    Eaton 9SX Extended Battery Modules Runtimes

    Battery runtimes are approximate and will VAry with equipment, configuration, battery age, temperature, etc. The actual runtime may VAry from +/- 15% around these typical Values.

    # of EBM/s 180 Watts 540 Watts 900 Watts 1260 Watts 1620 Watts 1800 Watts
    9SX2000I (No EBMs) 100 Mins 33 Mins 20 Mins 12 Mins 8 Mins 7 Mins
    9SX2000I + 1 EBM 491 Mins 162 Mins 93 Mins 62 Mins 45 Mins 40 Mins
    9SX2000I + 2 EBMs 900 Mins 300 Mins 174 Mins 118 Mins 87 Mins 77 Mins
    9SX2000I + 3 EBMs 1200 Mins 489 Mins 268 Mins 177 Mins 133 Mins 116 Mins
    9SX2000I + 4 EBMs 1867 Mins 591 Mins 386 Mins 245 Mins 176 Mins 160 Mins
    # of EBM/s 270 Watts 810 Watts 1350 Watts 1890 Watts 2430 Watts 2700 Watts
    9SX3000I (No EBMs) 84 Mins 29 Mins 16 Mins 10 Mins 7 Mins 6 Mins
    9SX3000I + 1 EBM 300 Mins 108 Mins 61 Mins 42 Mins 31 Mins 29 Mins
    9SX3000I + 2 EBMs 555 Mins 194 Mins 113 Mins 78 Mins 58 Mins 52 Mins
    9SX3000I + 3 EBMs 857 Mins 289 Mins 168 Mins 115 Mins 87 Mins 79 Mins
    9SX3000I + 4 EBMs 1100 Mins 421 Mins 228 Mins 158 Mins 115 Mins 106 Mins
    Model 9SX 700I 9SX 1000I/IR 9SX 1500I/IR 9SX 2000I/IR 9SX 3000I/IR
    Rating (VA/W) 700VA/630W 1000VA/900W 1500VA/1350W 2000VA/1800W 3000VA/2700W
    Format Tower Tower or Rack (2U)
    Electrical Characteristics
    Technology On-line double-conversion with Power Factor Correction (PFC) system.
    Nominal Voltage 200/208/220/230/240V
    Input Voltage Range 190-276V without derating (up to 120-276V with derating) 200-276V without derating (up to 140-276V with derating)
    Input Frequency Range/THDI 40-70Hz, 50/60Hz autoselection, frequency converter mode.
    Connections
    Input 1 x IEC C14 (10A) 1 x IEC C14 (10A) 1 x IEC C14 (10A) 1 x IEC C14 (10A) 1 x IEC C20 (20A)
    Outputs 6 x IEC C13 (10A) sockets 6 x IEC C13 (10A) sockets 6 x IEC C13 (10A) sockets 8 x IEC C13 (10A) sockets 8 x IEC C13 (10A) sockets + 1 x IEC 19 (16A) socket
    Switched Outlet Group 2 outlet groups
    Communication
    Communication Ports 1 USB port + 1 serial RS232 port + 1 mini-terminal block for Remote Power Off + 1 mini-terminal block for Output relay.
    Communication Slot 1 slot for Network-M2, Network-MS, ModBus-MS or Relay-MS cards.
    Operating Conditions, Standards and approvals
    Operating temperature 0 to 40C
    Typical noise level 40dB 41dB 43dB 45dB 45dB
    Typical Noise Level EC/EN 62040-1, UL 1778, CSA 22.2
    EMC IEC/EN 62040 -2, FCC Class B, CISPR22 Class B
    Approvals & marking CE/CB report (TUV)/cULus/EAC/RCM/BIS (Tower models only)/KCC (Tower models only)
    Dimensions H x W x D in mm/Weight
    UPS 252x160x357/11.5kg Tower: 252x160x387/14.8kg
    Rack: 86.5x438x438/15.7kg
    Tower: 252x160x437/18.5kg
    Rack: 86.5x438x438/18.4kg
    Tower: 346x214x412/33.3kg
    Rack: 86.5x438x608/26.5kg
    Tower: 346x214x412/33.4kg
    Rack: 86.5x438x608/26.5kg
    EBM Tower: 252x160x387/19kg
    Rack: 86.5x438x438/22.2kg
    Tower: 252x160x387/24.5kg
    Rack: 86.5x438x438/27.4kg
    Tower: 346x214x412/48.7kg
    Rack: 86.5x438x608/40.5kg
    Tower: 346x214x412/48.7kg
    Rack: 86.5x438x608/40.5kg
    Customer Service and Support
    Warranty 2 Years
    Batteries
    Typical backup times* (minutes)/load 300W 500W 800W 1200W 1800W 2500W
    9SX 700 14 7.5
    9SX 1000 24 14 7
    9SX 1000 + 1 EBM/+ 4 EBM 90/320 56/200 33/120
    9SX 1500 39 23 12 7
    9SX 1500 + 1 EBM/+ 4 EBM 142/520 85/310 50/179 31/115
    9SX 2000 (Tower) 62 36 22 13 7
    9SX 2000 (Tower) + 1 EBM/+ 4 EBM 280/1050 165/620 100/390 65/250 40/160
    9SX 2000 (Rack) 42 25 14 8 4.5
    9SX 2000 (Rack) + 1 EBM/+ 4 EBM 210/800 120/480 72/270 45/175 30/118
    9SX 3000 (Tower) 78 45 29 17 10 6
    9SX 3000 (Tower) + 1 EBM/+ 4EBM 290/1100 175/630 108/421 68/255 45/168 30/112
    9SX 3000 (Rack) 57 33 20 12 7 4
    9SX 3000 (Rack) + 1 EBM/+ 4 EBM 220/820 125/490 77/280 50/180 32/121 22/81
    Battery Management ABM and Temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of external battery units.

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us