    The Loadstar range of AC/AC static inverter units offer the opportunity to create a discreet emergency lighting system, utilising suitable standard mains luminaires without modification. Small or decorative compact luminaires can also be easily incorporated.

    Loadstar AC/AC systems offer many benefits, including higher light levels in emergency mode, as all lamps in the luminaire are usually energised by the emergency supply.

    Mains voltage and lower currents enable cables of smaller cross-sectional areas to be used with low voltage AC/DC systems, without unacceptable levels of voltage drop. The proven and reliable modular design ensures a cost-effective emergency lighting solution.

    System Reference
    230V in / 230V out
    Inverter Power
    Rating (kVA)
    Output Watts
    (W)
    1 Hour Autonomy Cubicle Arrangement
    2 Hr Autonomy
    3Hr Autonomy
    AC1KVA/850/SLR* 1 850 931CBI 931CBI 931CBI
    AC2KVA/1700/SLR* 2 1700 931CBI 932CBI 932CBI
    AC2.5KVA/2125/SLR* 2.5 2125 931CBI 932CBI 932CBI
    AC3KVA/2550/SLR* 3 2550 932CBI 932CBI 932CBI
    AC4KVA/3400/SLR* 4 3400 932CBI 932CBI 932CBI
    AC5KVA/4250/SLR* 5 4250 934CBI 934CBI 934CBI
    AC6KVA/5100/SLR* 6 5100 934CBI 934CBI 932CI + 932B3
    AC7.5KVA/6375/SLR* 7.5 6375 934CBI 932CI + 932B3 932CI + 934B2
    AC8KVA/6800/SLR* 8 6800 934CBI 932CI + 932B3 932CI + 934B3
    AC9KVA/7650/SLR* 9 7650 932CI + 932B3 932CI + 934B2 932CI + 934B3
    AC10KVA/8500/SLR* 10 8500 932CI + 932B3 932CI + 932B2 932CI + 934B3
    AC11KVA/9350/SLR* 11 9350 932CI + 932B3 932CI + 932B3 932CI + 2 x 932B3
    AC12KVA/10200/SLR* 12 10200 932CI + 932B3 932CI + 932B3 932CI + 2 x 932B3
    AC13KVA/11050/SLR* 13 11050 932CI + 932B3 932CI + 932B3 932CI + 932B3 + 934B3
    AC14KVA/11900/SLR* 14 11900 932CI + 932B3 932CI + 932B3 932CI + 932B3 + 934B3
    AC15KVA/12750/SLR* 15 12750 932CI + 932B3 932CI + 2 x 932B3 932CI + 932B3 + 934B3
    AC16KVA/13600/SLR* 16 13600 932CI + 932B3 932CI + 2 x 932B3 932CI + 2 x 934B3
    AC17.5KVA/14875/SLR* 17.5 14875 934CI + 934B2 934CI + 934B3 + 932B1 934CI + 3 x 932B3
    AC18KVA/15300/SLR* 18 15300 934CI + 934B2 934CI + 934B3 + 932B3 934CI + 3 x 932B3
    AC19KVA/16150/SLR* 19 16150 934CI + 934B2 934CI + 934B3 + 932B3 934CI + 2 x 934B3
    AC20KVA/17000/SLR* 20 17000 934CI + 934B3 934CI + 2 x 934B2 934CI + 932B3 + 2 x 934B3
    AC21KVA/17850/SLR* 21 17850 934CI + 932B3 + 932B1 934CI + 2 x 934B2 934CI + 932B3 + 2 x 934B3
    AC22KVA/18700/SLR* 22 18700 934CI + 932B3 + 932B1 934CI + 3 x 932B3 934CI + 932B3 + 2 x 934B3
    AC23KVA/19550/SLR* 23 19550 934CI + 932B3 + 932B1 934CI + 3 x 932B3 934CI + 932B2 + 2 x 934B3
    AC24KVA/20400/SLR* 24 20400 934CI + 934B3 934CI + 3 x 932B3 934CI + 2 x 934B3 + 932B2
    AC25KVA/21250/SLR* 25 21250 934FC + 932I + 934B3 934FC + 932I + 3 x 932B3 934FC + 932I + 2 x 934B3 + 932B3

    AC/AC SLR Range, 0.85 Power Factor (400V in / 400V out)

    System Reference
    400V in / 400V out
    Inverter Power
    Rating (kVA)
    Output
    Watts (W)
    1 Hour Autonomy Cubicle Arrangement
    2 Hr Autonomy
    3 Hr Autonomy
    AC26KVA/22100/SLR*/TPN4W 26 22100 934FC + 934I + 2 x 932B3 934FC + 934I + 2 x 934B3 934FC + 934I + 2 x 934B3 + 2 x 932B3
    AC28KVA/23800/SLR*/TPN4W 28 23800 934FC + 934I + 934B3 + 932B1 934FC + 934I + 2 x 934B3 + 932B3 934FC + 934I + 3 x 934B3
    AC30KVA/25500/SLR*/TPN4W 30 25500 934FC + 934I + 2 x 932B3 934FC + 934I + 2 x 934B3 + 932B2 934FC + 934I + 4 x 934B3
    AC32KVA/27200/SLR*/TPN4W 32 27200 934FC + 934I + 934B3 + 932B3 934FC + 934I + 2 x 934B3 + 932B2 934FC + 934I + 4 x 934B3
    AC34KVA/28900/SLR*/TPN4W 34 28900 934FC + 934I + 934B3 + 932B3 934FC + 934I + 2 x 934B3 + 932B3 934FC + 934I + 4 x 934B3 + 934B1
    AC36KVA/30600/SLR*/TPN4W 36 30600 934FC + 934I + 934B3 + 932B3 934FC + 934I + 2 x 934B3 + 932B3 934FC + 934I + 4 x 934B3 + 934B1
    AC38KVA/32300/SLR*/TPN4W 38 32300 934FC + 2 x 932I + 934B3 + 932B3 934FC + 2 x 932I + 3 x 934B3 934FC + 2 x 932I + 4 x 934B3 + 934B1
    AC40KVA/34000/SLR*/TPN4W 40 34000 934FC + 2 x 932I + 2 x 934B3 934FC + 2 x 932I + 3 x 934B3 934FC + 2 x 932I + 5 x 934B3
    AC42KVA/35700/SLR*/TPN4W 42 35700 934FC + 2 x 932I + 2 x 934B3 934FC + 2 x 932I + 4 x 934B3 934FC + 2 x 932I + 3 x 934B3 + 3 x 932B3
    AC44KVA/37400/SLR*/TPN4W 44 37400 934FC + 2 x 932I + 3 x 932B3 934FC + 2 x 932I + 4 x 934B3 934FC + 2 x 932I + 5 x 934B3
    AC46KVA/39100/SLR*/TPN4W 46 39100 934FC + 2 x 932I + 3 x 932B3 934FC + 2 x 932I + 4 x 934B3 + 934B1 934FC + 2 x 932I + 3 x 934B3 + 3 x 932B3
    AC48KVA/40800/SLR*/TPN4W 48 40800 934FC + 2 x 932I + 2 x 934B3 + 932B3 934FC + 2 x 932I + 4 x 934B3 + 934B1 934FC + 2 x 932I + 6 x 934B3
    AC50KVA/42500/SLR*/TPN4W 50 42500 934FC + 934I + 932I + 2 x 934B3 + 932B3 934FC + 934I + 932I + 4 x 934B3 + 934B1 934FC + 934I + 932I + 6 x 934B3
    AC52KVA/44200/SLR*/TPN4W 52 44200 934FC + 934I + 932I + 2 x 934B3 + 932B3 934FC + 934I + 932I + 4 x 934B3 + 934B1 934FC + 934I + 932I + 4 x 934B3 + 4 x 932B3
    AC54KVA/45900/SLR*/TPN4W 54 45900 934FC + 934I + 932I + 2 x 934B3 + 932B2 934FC + 934I + 932I + 4 x 934B3 + 934B1 934FC + 934I + 932I + 4 x 934B3 + 4 x 932B3
    AC56KVA/47600/SLR*/TPN4W 56 47600 934FC + 934I + 932I + 2 x 934B3 + 932B2 934FC + 934I + 932I + 5 x 934B3 934FC + 934I + 932I + 4 x 934B3 + 4 x 932B3
    AC58KVA/49300/SLR*/TPN4W 58 49300 934FC + 934I + 932I + 2 x 934B3 + 932B2 934FC + 934I + 932I + 4 x 934B3 + 934B1 934FC + 934I + 932I + 4 x 934B3 + 4 x 932B3
    AC60KVA/51000/SLR*/TPN4W 60 51000 934FC + 934I + 932I + 2 x 934B3 + 932B3 934FC + 934I + 932I + 4 x 934B3 + 934B1 934FC + 934I + 932I + 4 x 934B3 + 4 x 932B3

    * Denotes the system autonomy i.e. AC1KVA/850/SLR3 = 3Hr Backup Autonomy

    ≈ Denotes cubicles size/quantity information is available on application

    NOTE: The above solutions may change depending on batteries availability

    AC/AC SLR Range, Unity Power Factor

    System Reference Inverter Power
    Rating (kVA
    )
    Output
    Watts (W)
    1 Hour Autonomy Cubicle Arrangement
    2 Hr Autonomy
    3 Hr Autonomy
    AC1KVA/1000/SLR3* 1.0 1000 ≈ ≈ ≈
    AC2KVA/2000/SLR* 2.0 2000 ≈ ≈ ≈
    AC2.5KVA/2500/SLR* 2.5 2500 ≈ ≈ ≈
    AC3KVA/3000/SLR* 3.0 3000 ≈ ≈ ≈
    AC4KVA/4000/SLR* 4.0 4000 ≈ ≈ ≈
    AC5KVA/5000/SLR* 5.0 5000 ≈ ≈ ≈
    AC6KVA/6000/SLR* 6.0 6000 ≈ ≈ ≈
    AC7.5KVA/7500/SLR* 7.5 7500 ≈ ≈ ≈
    AC8KVA/8000/SLR 8.0 8000 ≈ ≈ ≈
    AC9KVA/7650/SLR* 9.0 9000 ≈ ≈ ≈
    AC10KVA/1000/SLR* 10.0 10000 ≈ ≈ ≈
    AC11KVA/11000/SLR* 11.0 11000 ≈ ≈ ≈
    AC12KVA/12000/SLR* 12.0 12000 ≈ ≈ ≈
    AC13KVA/13000/SLR* 13.0 13000 ≈ ≈ ≈
    AC14KVA/14000/SLR* 14.0 14000 ≈ ≈ ≈
    AC15KVA/15000/SLR* 15.0 15000 ≈ ≈ ≈
    AC16KVA/16000/SLR* 16.0 16000 ≈ ≈ ≈
    AC17.5KVA17500/SLR* 17.5 17500 ≈ ≈ ≈
    AC18KVA/18000/SLR* 18.0 18000 ≈ ≈ ≈
    AC19KVA/19000/SLR* 19.0 19000 ≈ ≈ ≈
    AC20KVA/20000/SLR* 20.0 20000 ≈ ≈ ≈
    AC21KVA/21000/SLR* 21.0 21000 ≈ ≈ ≈
    AC22KVA/22000/SLR* 22.0 22000 ≈ ≈ ≈
    AC23KVA/23000/SLR* 23.0 23000 ≈ ≈ ≈
    AC24KVA/24000/SLR* 24.0 24000 ≈ ≈ ≈
    AC25KVA/25000/SLR* 25.0 25000 ≈ ≈ ≈
    AC26KVA/26000/SLR* 26.0 26000 ≈ ≈ ≈
    AC28KVA/28000/SLR* 28.0 28000 ≈ ≈ ≈
    AC30KVA/30000/SLR* 30.0 30000 ≈ ≈ ≈
    AC32KVA/32000/SLR* 32.0 32000 ≈ ≈ ≈
    AC34KVA/34000/SLR* 34.0 34000 ≈ ≈ ≈
    AC36KVA/36000/SLR* 36.0 36000 ≈ ≈ ≈
    AC38KVA/38000/SLR* 38.0 38000 ≈ ≈ ≈
    AC40KVA/40000/SLR* 40.0 40000 ≈ ≈ ≈
    AC42KVA/42000/SLR* 42.0 42000 ≈ ≈ ≈
    AC44KVA/44000/SLR* 44.0 44000 ≈ ≈ ≈
    AC46KVA/46000/SLR* 46.0 46000 ≈ ≈ ≈
    AC48KVA/48000/SLR* 48.0 48000 ≈ ≈ ≈
    AC50KVA/50000/SLR* 50.0 50000 ≈ ≈ ≈
    AC52KVA/52000/SLR* 52.0 52000 ≈ ≈ ≈
    AC54KVA/54000/SLR* 54.0 54000 ≈ ≈ ≈
    AC56KVA/56000/SLR* 56.0 56000 ≈ ≈ ≈
    AC58KVA/58000/SLR* 58.0 58000 ≈ ≈ ≈
    AC60KVA/60000/SLR* 60.0 60000 ≈ ≈ ≈

    * Denotes the system autonomy i.e. AC1KVA/850/SLR3 = 3Hr Backup Autonomy

    ≈ Denotes cubicles size/quantity information is available on application

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.