Eaton Managed G4 Rack PDU, 0U, Three Phase, 11kW, 16A, 42 outlets (24)C13, (18)C39 - EVMAF316X

  • Order Now. Speak to a Specialist. Call 0800 978 8988.
  • ETA will be advised upon ordering or call us.

£2018.11 Ex VAT
£2421.73 Inc VAT

Delivery Costs

Find below some of our pricing costs for Critical Power Supplies online store.

England, Wales and Scottish Lowlands

2 to 3 Working Days - £4.99.
Next Working Day - £9.99.
Pre Noon, Pre 10:30am - Contact Us.

Scottish Lowlands Postcodes
AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9

Highlands, Northern Ireland, Channel Islands and Ireland

  • Scottish Highlands
    3 to 5 Working Days - £20

    Scottish Highlands Postcodes
    AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4

  • Northern Ireland
    3 to 5 Working Days - £50

  • Channel Islands
    3 to 5 Working Days - £25

  • Ireland
    5 to 7 Working Days - £99

  • Western Europe
    5 to 7 Working Days - £150 DAP
    DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.

Purchase this item and get 20181 Points - equivalent to the value of £20.18
Add to Wishlist

All major debit and credit cards accepted.

  • Description

    Eaton’s new rack PDU G4 delivers highly secured power distribution and business continuity, critical in today’s data centre space. This has been achieved by in-depth work, incorporating customer experience and marketplace feedback.

    The result is G4’s revolutionary single C39 outlet that combines both C13 10A and C19 16A specifications. This offers unprecedented flexibility and ease of use. The only question now is: how many outlets do you need? Not which kind. Not only does G4 take cybersecurity to new levels but it also brings big increases in network and power redundancy, underpinned by reduced energy requirements. Eaton Power Distribution Units match solutions to needs with four rack PDU G4 technologies.

  • Technical Data
    PRODUCT NAME
    Eaton Rack PDU G4
    CATALOG NUMBER
    EVMAF316X
    MODEL CODE
    PDU G4 MA 0U 309 16A 3P 24xC13,18xC39
    EAN
    3553340696916
    PRODUCT LENGTH/DEPTH
    1730 mm
    PRODUCT HEIGHT
    53 mm
    PRODUCT WIDTH
    52 mm
    PRODUCT WEIGHT
    4.8 kg
    COMPLIANCES
    • CB
    • LVD Directive
    • RoHS Directive
    • WEEE Directive
    • Packaging Directive
    • EMC Directive
    CERTIFICATIONS
    • IEC 62368-1
    • EN IEC 63000
    • CE
    • EAC
    • UKCA
    • Cm
    • Ukr
    • IEC/EN 61000-6-2
    • IEC/EN 61000-6-4
    • EN 61000-3-2
    • EN 61000-3-3
    • CISPR 35/EN 55035

    PRODUCT SPECIFICATIONS

    SPECIAL FEATURES
    • Remote Site Management
    • Versatile C39 outlet supports C14 or C20 power cord plug
    • High retention outlets designed to securely fit standard power cords and support P-Lock power cords
    • Cybersecurity standards UL 2900-1 and IEC 62443-4-2
    • Hot-Swap network control module
    • Network Cascading, connect up to 32 PDUs via network loop
    • Power sharing between two network modules PDUs ensures constant access to PDU data & sensors
    • 1% IEC Class 1 billing grade measurement accurancy
    • Gigabit network card with 2x Gb ports
    • Support protocols RestAPI, Modbus TCP, SNMP, LDAP, HTTPS
    • 1% measurement accuracy at the outlet level (V, W, A)
    • Outlets control for On/Off, reboot, and sequential start-up capabilities
    TYPE
    Managed Rack PDU
    FORM FACTOR
    0U (Vertical)
    OUTLET CONTROL
    Yes
    ACCESSORIES
    • Rack PDU
    • Rack mounting accessories
    • Quickstart guide
    • Safety Instructions
    OPERATING TEMPERATURE
    0° to 60°C (32° to 140°F)
    MOUNTING DIRECTION
    Vertical
    COLOR
    Black
    MATERIAL
    Aluminium
    INPUT CONNECTION
    IEC-60309 16A 3ph
    CORD LENGTH
    3m
    WATTAGE
    11 kW max
    AMPERAGE RATING
    16A
    INPUT VOLTAGE
    240/415V
    PHASE
    Three-phase
    FREQUENCY RATING
    50/60 Hz
    OUTLETS
    (24) C13, (18) C39
    NUMBER OF OUTPUTS C13
    24
    NUMBER OF OUTPUTS C19
    18
    NUMBER OF OUTPUTS (OTHER)
    18
    NUMBER OF OUTLETS WITH EARTH PIN
    42
    SNMP
    Yes
    ETHERNET INTERFACE
    Yes
    SERIAL INTERFACE
    Yes
    MASS CONFIGURATION
    Yes
    ELECTRICAL CONNECTION
    Connecting cord with plug
    EVALUATION
    At distance
    MOUNTING DIMENSION (METRICAL)
    52
    MOUNTING DIMENSION (STANDARDIZED)
    Metric
    SWITCHABLE
    Yes
    OVER VOLTAGE CATEGORY
    2
    SERIES
    G4
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.