Gone in a FLASH

Black Friday Deals

SKU: ACCU300 Categories: , Brand: APC Tag:

APC InRow 30kW Condensing Unit, 208V, Single feed - ACCU300

  • Available to pre-order.
  • ETA will be advised upon ordering or call us on 0800 978 8988 for leadtime.
We are an APC Premier Partner!
Call for Pricing - 0800 978 8988
  • Description

    Uniflair Direct Expansion InRow Cooling Features & Benefits

    Serviceability

    Easy service access Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

    Total cost of Ownership

    Row-based architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.

    Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.

    Availability

    Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

    Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

    Rack inlet temperature control Reduces the risk of hot spots at the rack level

    Manageability

    Building management system integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.

    Microprocessor controller Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display

    Real-Time capacity monitoring Real-time display of current and available cooling.

    Agility

    Modular design Modular design provides scalable solutions to add cooling as demand increases.

    Scalable densities Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

  • Technical Data

    Input

    Input frequency 50/60 Hz
    Power Feeds 1.0

    Physical

    Maximum Height 1600MM, 160.0CM
    Maximum Width 1001MM, 100.1CM
    Maximum Depth 1001MM, 100.1CM
    Net Weight 266.98KG
    Shipping weight 297.0KG
    Shipping Height 1136MM, 113.6CM
    Shipping Width 1085MM, 108.5CM
    Shipping Depth 1745MM, 174.5CM

    Conformance

    Approvals cUL listed, UL listed
    Standard warranty 1 year on-site repair or replace with factory authorized Start-Up

    General

    Air Discharge Patterns Upflow
    Compressor Type Scroll
    Intake Air Top return
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

  • Downloads

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us