Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988
Riello Multi Power 2 Modular Online PC0 1600kVA UPS - M2S 1600 PC0
- ✔ Trusted UK Supplier
- ✔ Fast UK Delivery Available
- ✔ Manufacturer Warranty Included
- ✔ Expert Advice Available
- ✔ Protects equipment from power loss
- ✔ Prevents downtime and data loss
- ✔ Suitable for business and home setups
Please email me when stock is available
Call 0800 978 8988
- Description
- Technical Data
- Onsite Maintenance
- Downloads
The biggest challenge of our time is sustainability. This is the reason why we developed the Multi Power 2 Power Module based on the latest silicon carbide technology (SiC), which reduces cooling requirements whilst enabling more compact, more reliable, and more robust solutions.
The UPS Power Modules could reach an efficiency of up to 98.1% in ON LINE double conversion, providing the best power supply to critical equipment whilst minimising operating costs and energy losses.
High efficiency is achieved even in the case of extremely low loads thanks to the Efficiency Control Mode, where the system will automatically activate only the required number of UPS Power Modules, ensuring the highest efficiency and, at the same time, the required redundancy level.
Multi Power 2 can also work in temperatures up to 40°C (without any derating), minimising the need for energy-intensive cooling systems.
Extremely Flexible
The Multi Power 2 has been conceived to meet the specific needs of each installation and quickly adapt to any load increase. Thanks to hot-swappable Power Modules, any increase in power can be done while the unit is still working in ON LINE double conversion without any disruption to the load.
All the major components of the UPS are modular and can be easily added to and/or replaced, minimising the site intervention cost whilst avoiding any downtime.
The range incorporates:
- MP2: up to 500 kW
- M2S: scalable from 1000 kW to 1600 kW
The MP2 chassis can hold up to 8 Power Modules, while M2S has capacity for:
- M2S 1000 = up to 15 modules (20 slots in total)
- M2S 1250 = up to 19 modules (20 slots in total)
- M2S 1600 = up to 24 modules (30 slots in total)
The spare slots are designed to offer users flexibility in terms of redundancy.
Several configuration and frames are also available:
- PCM: very compact solution with integrated manual bypass.
- PC0: unit supplied with unique I/O and without switches to simplify the integration with the existing electrical infrastructure and to meet any space constraints.
- PCS: fully integrated, for a complete, simple and very reliable installation, with main input, bypass, manual bypass and output switches.
Reliable & Resilient
The Multi Power 2 is extremely reliable as it is designed to avoid any single point of failure. This principle is applied to all the parts of the unit, even to the internal communication structure, which is completely redesigned and made with two separate and fully redundant high-speed buses.
To provide the highest level of quality and process control, each component of the system, from the modules to the cabinet, is designed and manufactured in Italy. All modules and full units undergo specific tests to verify that each component operates correctly.
All collected measurements and data are analysed to keep improving our products and provide our customers with the most up to date technologies. To enhance the lifespan of the UPS, each module incorporates status counters, as well as temperature and humidity sensors, providing real-time analytics for operators.
Furthermore, thanks to embedded intelligence, power computing capacity, and outstanding connectivity, we can monitor remotely the status of the UPS and provide dynamic and bespoke after sales services.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.
1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts
For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.
| Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. | |
| Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. | |
| Battery Plus, Provides replacement batteries to site, next working day replacement or same day |
2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts
No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.
|
Services Included |
Silver Level |
Gold Level |
Platinum Level |
Platinum Plus |
|
| Technical Hotline 24/7 | Yes | Yes | Yes | Yes | |
| Preventative Maintenance | Yes | Yes | Yes | Yes | |
| Remote Monitoring 24/7 | Yes | Yes | Yes | Yes | |
| Firmware Upgrades | Yes | Yes | Yes | Yes | |
| Emergency Response | Yes | Yes | Yes | Yes | |
| Labour | Yes | Yes | Yes | Yes | |
| Parts | Yes | Yes | Yes | option | |
| Monthly Event/Status Report | option | option | option | option | |
| Onsite Crash Kit | option | option | option | onsite | |
| Response Time | 12 working hours | 8 working hours | 4 clock hours | 4 clock hours | |
| Guaranteed Fix time | – | – | – | 4 Clock hours |
3: 24×7 Remote Monitoring Contracts –
Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.
| Engineer Installation and configuration during normal hours | |
| 24×7 flexible status and remote monitoring. | |
| Encrypted communication, allowing safe offsite monitoring | |
| Alarms and events emailed and SMS texted automatically | |
| Firewall Friendly | |
| Cloud based status overview and multiple sites status on one screen | |
| Allows First Fix Response to Site |
4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.
Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.
5. Switchgear – Contact us for more information.
Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.
- Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
- Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
- Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.
Our brands
Shown below is a small selection of some of our customers we have helped through understanding clients challenges and implementing our unique approach to helping clients built around: listening to our clients, understanding the challenges they face and providing a range of options which compliments their requirements. Our aim is not to sell products but provide solutions with the help of our in house Power Consultants and Electricians.