Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988
SKU: MP2 300 PCM Categories: , , ,

Riello Multi Power 2 MP2 300 PCM Power Cabinet

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups

    Tailor to your needs. Speak to a Specialist.
    Call: 0800 978 8988

    Please email me when stock is available

    Product and delivery enquiries
    Call 0800 978 8988

    All major debit and credit cards accepted.

    Smart, Scalable, Sustainable Power

    Multi Power2 (MP2 & M2X) is our evolution of modular UPS that raises the bar for efficiency, flexibility, and performance in high-density computing environments such as data centres and mission-critical applications.

    Fully Scalable Solution

    Multi Power2 offers solutions in 3 different cabinet sizes and two different technologies (M2X 120 kW and MP2 300-500-600 kW versions) that enable you to protect up to 600 kW in a single cabinet. Smart modular architecture ensures the system adapts to load demands to avoid oversizing and optimise day-to-day running costs.

    Proven Performance Guaranteed

    A step forward in the technology of every component, from the power modules and cabinets through to internal communications structure, ensures even higher power density in a reduced footprint. Designed to avoid any single point of failure, while hot-swappable modules guarantee downtime-free maintenance and system expansion.

    Best In Class Efficiency

    New high-density power modules capable of up to 98.1% efficiency in double conversion online mode, providing the best power supply to critical equipment whilst minimising operating costs and energy losses. Efficiency Control Mode ensures high efficiency at all load levels.

    In addition MP2 & M2X, the Multi Power2 family incorporates the Multi Power2 Scalable (M2S) available in 1000-1250-1600 kw versions

    HIGHLIGHTS

    • Ultra-high efficiency up to 98.1% (ONLINE mode)
    • Efficiency Control Mode ensures high efficiency even at low loads
    • Best-in-class power density delivers performance in compact footprint
    • Risk-free ‘pay as you grow’ scalability
    • Downtime-free maintenance thanks to hot-swappable modules
    • Robust design eliminates any single point of failure
    • Optimise initial investment and maximise Total Cost of Ownership (TCO)
    • Smart Modular Architecture (SMA)

    he biggest challenge of our time is sustainability. This is the reason why we developed the Multi Power2 power module based on the latest silicon carbide technology (SiC), which reduces cooling requirements whilst enabling more compact, more reliable, and more robust solutions.

    These new power modules can reach ultra-high efficiency up to 98.1% in ON LINE double conversion mode, providing the best power supply to critical equipment whilst minimising operating costs and energy losses.

    High efficiency is achieved even in case of extremely low loads thanks to the sophisticated Efficiency Control Mode, where the system will automatically activate only the required number of Power Modules, according to the real-time load ensuring the highest efficiency.

    Multi Power2 can also work in temperatures up to 40°C without any derating, minimising the demand and consumption of cooling systems.

     

    Ultimate Flexibility

    Multi Power2 has been conceived to meet the specific needs of each installation and quickly adapt to any load increase.

    Thanks to the hot-swappable Power Modules, any increase in power can be done while the unit is still working in ON LINE double conversion without any disruption to the load.

    All the major components of the UPS are modular and can be easily added and/or replaced, minimising the site intervention cost whilst avoiding any downtime.

    Several configurations and frames are available:

    • PCM: very compact solution with integrated manual bypass;
    • PCO: unit supplied with unique I/O and without switches to simplify the integration with the existing electrical infrastructure and meet any space constraints;
    • PCS: fully integrated solution for a complete, simple, and reliable installation. Incorporates the main input, bypass, manual bypass and output switches.
    • CBC 6: compact solution that includes internal backup time, manual bypass, and integrated battery switch.

    Smart Modular Architecture

    Multi Power2 (MP2 and M2X) is the result of a new design approach focused on a deep interconnection between hardware and software. It provides an extremely reactive system which ensures business continuity in every operating condition.

    Intelligence is distributed to ensure the protection of the equipment even on the off chance of a fault on a power module.

    Automatic health checks are performed during the plug-in of each module to verify its status and avoid defective components, while the firmware automatically aligns to the latest version as and when additional modules are added to the system.

    While thanks to the embedded intelligence, power computing capacity, and outstanding connectivity, we can monitor remotely the status of the UPS and provide bespoke after sales service to help maximise the overall lifespan of the unit.

    Downtime-Free Maintenance Guaranteed

    Each power module and battery unit is easily accessible from the front of the cabinet and hot-swappable. This ensures any module can be serviced, maintained, or even replaced while the rest of the system continues to protect the load, minimising the Mean Time to Repair (MTTR).

    In addition, every connection terminal is accessible straight from the front of the unit to enable safe and easy deployment.

    Models MP2 300 PCM
    OVERALL SPECIFICATION
    Battery cabinet type MP2 300 PCM Power Cabinet
    Power module(PM)nominal power 67 kW
    Solution nominal Power 300 kW
    Output power factor [pf] 1
    Parallel (up to) 4
    Cabinet layout description Up to 5 x MP2 67 PM BLUE or 5 x MP2 67 PM. Unit with manual bypass switch.
    INPUT
    Rated power 300000 VA
    Voltage 380 / 400 / 415 V three-phase + N
    Frequency tolerance 40 – 72 Hz
    Power factor 0.99
    BY PASS
    Rated voltage 380 / 400 / 415 V three-phase + N
    Voltage tolerance From 180 V (adjustable 180-200) to 264 V (adjustable 250 – 264) referring to neutral (Ph-N)
    Rated frequency 50 or 60 Hz (selectable)
    Frequency tolerance ± 5% (selectable)
    Number phases 3 + N
    OUTPUT and INVERTER OUTPUT
    Rated power 300000 VA
    Active power 300000 W
    Number phases 3 + N
    Output voltage 380 / 400 / 415 V three-phase + N
    Waveform Sinewave
    Dynamic stability EN62040-3 class performance 1 non-linear load
    Frequency 50 or 60 Hz
    Overload 125% for 10 min.; 150% for 1 min.
    BATTERIES
    Type VRLA AGM / GEL; NiCd; Li-Ion; Supercaps
    Type of charging One level, Two level, Cyclic recharge (selectable)
    ENVIRONMENTAL
    Color RAL 9005
    Communication 10” Graphic touch screen display – UPS Status led bar – 2 slots for communication interface, 5 input, 4 output signals and embedded NetMan 208
    Protection rating IP20 finger proof (either with cabinet doors open or close)
    AC/AC efficiency Up to 98.1% with MP2 67 PM BLUE (ON LINE mode)
    Operating temperature 0 °C – +40 °C
    Relative humidity 5-95% non condensing
    Standards European directives: LV 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility — Directive & Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant — Classification in accordance with IEC 62040-3 VFI – SS – 111
    DATA
    Weight including PMs to reach nominal power 429 kg
    Dimensions (h w d) 1995 x 600 x 940 mm
    Input phases 3
    Output phases 3

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.