Secure Checkout
UK-Based Company
Manufacturer Warranty
Call Us: 0800 978 8988
Riello PowerShield 3 Full Monitoring Software - PowerShield3 Full
- ✔ Trusted UK Supplier
- ✔ Fast UK Delivery Available
- ✔ Manufacturer Warranty Included
- ✔ Expert Advice Available
- ✔ Protects equipment from power loss
- ✔ Prevents downtime and data loss
- ✔ Suitable for business and home setups
£96.99 Ex VAT £116.39 Inc VAT
Delivery Costs
Find below some of our pricing costs for Critical Power Supplies online store.
England, Wales and Scottish Lowlands
2 to 3 Working Days - £4.99. Next Working Day - £9.99. Pre Noon, Pre 10:30am - Contact Us.
Scottish Lowlands Postcodes AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9
Highlands, Northern Ireland, Channel Islands and Ireland
Scottish Highlands 3 to 5 Working Days - £20
Scottish Highlands Postcodes AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4
Northern Ireland 3 to 5 Working Days - £50
Channel Islands 3 to 5 Working Days - £25
Ireland 5 to 7 Working Days - £99
Western Europe 5 to 7 Working Days - £150 DAP DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.
Available to order — We’ll confirm availability after your order is placed.
Available to order — We’ll confirm availability after your order is placed.
Delivery options, charges and estimated delivery times are shown at checkout.
Need this urgently? Contact Sales to confirm availability and delivery options.
Call 0800 978 8988
All major debit and credit cards accepted.
- Description
- Onsite Maintenance
- Downloads
*Compatible with: Windows 8, Windows 10, Windows 2012 Server, Linux, Redhat, Ubuntu, Debian, Oracle, CentOS and Mac
The PowerShield UPS Monitoring Software from Critical Power Supplies is a complete package (allowing communication with up to 31 Riello UPS via TCP/IP, 1 UPS via RS232 and enables the parallel functionality feature for parallel systems) and provides user-friendly UPS management.
The software displays real time information in the form of bar charts and values for critical data such as mains voltage, UPS load and battery charge%. It allows remote interrogation of UPS logs and operating parameters to help diagnose alarms and potential fault conditions. When instructed the software performs an automated safe power down of the protected PCs and file severs.
- PowerShield³ FULL version: supports up to maximum of 32 UPS for all operating systems.
- With sequential and priority-based shutdown, PowerShield³ provides unattended shut-down of all networked PCs, saving any active work on the most widely used applications. Users can define the shutdown priorities for the various computers in the network and can also customise the procedure.
- With multi-platform compatibility, PowerShield³ uses the TCP/IP communications protocol to achieve standardised management and monitoring across the widest possible range of platforms. This makes it possible to monitor computers with different operating systems from a single console, for example monitoring a UNIX server from a PC running Windows and also connecting to UPS located in different geographical areas using dedicated networks (intranets) or the Internet.
- With event scheduling, PowerShield³ users can program their own shutdown procedures, detailing power-off and power-up scenarios to increase system security and save energy.
- With messages management, PowerShield3 keeps users constantly informed about the status of UPS and environmental sensors, either locally or via network messages. A list can also be defined of users who should receive e-mails, faxes, voice messages and SMS messages when faults or sudden mains power supply failures occur.
- Integrated SNMP agent: PowerShield³ features an integrated SNMP agent for UPS management which can send all the information required and generate traps using the RFC1628 standard, and environmental sensors.
- Secure, easy to use and connect; communication is now password protected to ensure UPS system security. Using the new discovery/ browsing function, all UPS connected to a protected computer and/or LAN can be displayed in a list format for monitoring. In the absence of a LAN connection, support is provided for modem-based communication.
Developed for virtualized systems
PowerShield³ permits to initiate live migration of virtual machines (VM) to automatically and transparently migrate VMs during power disturbance to protected devices by UPS with migration systems
such as VMware vMotion™ and Microsoft Live Migration. PowerShield3 can monitor and manage UPS either inside or outside the data centre. Can also measure power consumption to help calculate power usage effectiveness (PUE), a the standard metric utilized for gauging data centre power efficiency.
Security, easy to use and connect, communication is password protected to ensure UPS system security. Using the new discovery/browsing function, all the RIELLO UPS connected to a protected computer or LAN can be displayed in a list format. In the absence of a LAN connection, support is provided for modem based communication.
Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.
1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts
For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.
| Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. | |
| Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. | |
| Battery Plus, Provides replacement batteries to site, next working day replacement or same day |
2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts
No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.
|
Services Included |
Silver Level |
Gold Level |
Platinum Level |
Platinum Plus |
|
| Technical Hotline 24/7 | Yes | Yes | Yes | Yes | |
| Preventative Maintenance | Yes | Yes | Yes | Yes | |
| Remote Monitoring 24/7 | Yes | Yes | Yes | Yes | |
| Firmware Upgrades | Yes | Yes | Yes | Yes | |
| Emergency Response | Yes | Yes | Yes | Yes | |
| Labour | Yes | Yes | Yes | Yes | |
| Parts | Yes | Yes | Yes | option | |
| Monthly Event/Status Report | option | option | option | option | |
| Onsite Crash Kit | option | option | option | onsite | |
| Response Time | 12 working hours | 8 working hours | 4 clock hours | 4 clock hours | |
| Guaranteed Fix time | – | – | – | 4 Clock hours |
3: 24×7 Remote Monitoring Contracts –
Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.
| Engineer Installation and configuration during normal hours | |
| 24×7 flexible status and remote monitoring. | |
| Encrypted communication, allowing safe offsite monitoring | |
| Alarms and events emailed and SMS texted automatically | |
| Firewall Friendly | |
| Cloud based status overview and multiple sites status on one screen | |
| Allows First Fix Response to Site |
4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.
Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.
5. Switchgear – Contact us for more information.
Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.
- Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
- Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
- Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.
Our brands
Shown below is a small selection of some of our customers we have helped through understanding clients challenges and implementing our unique approach to helping clients built around: listening to our clients, understanding the challenges they face and providing a range of options which compliments their requirements. Our aim is not to sell products but provide solutions with the help of our in house Power Consultants and Electricians.