SKU: 699CC000002 Categories: , , Brand: Salicru Tag:

Salicru SLC-10000-TWIN/3 PRO2 - 699CC000002

  • Order Now. Speak to a Specialist. Call 0800 978 8988.
  • ETA will be advised upon ordering or call us on 0800 978 8988 for leadtime.

Tailor to your needs. Speak to a Specialist.
Call: 0800 978 8988

  • Description

    Salicru’s SLC TWIN PRO2 series UPS systems feature on-line double conversion technology, currently the most advanced for the protection of critical systems as it provides a fully stabilised and filtered sinusoidal supply voltage. The systems come in a tower format and are available in power ratings of 4, 5, 6, 8, 10, 15 and 20 kVA.

    The Salicru SLC TWIN PRO2’s output voltage is always single-phase, featuring a single-phase input of 4 to 20 kVA and a three-phase input of 8 to 20 kVA. All devices with single-phase input provide a unitary output power factor (1), the most optimum for systems and environments with high energy needs. Adaptability is another important feature thanks to the numerous operating modes available: On-line, Batteries, Eco-mode, Bypass, Frequency converter and Parallel redundant.

    The possibilities of control and monitoring are varied: on the one hand, an LCD display + keypad for local operation of the device, and, on the other, various communication options (USB HID and RS-232 interfaces, and slot for SNMP, RS-485 and AS-400 cards) that enable the UPS to be integrated into standard or virtualised platforms for management, incident notification and remote maintenance.
    (1) Except 15 and 20 kVA I / I models

  • Technical Data
    Power
    Output voltage regulation1%
    Output frequency regulation4 Hz
    Output power factor0.9
    Input power factor0.99
    Output power9000 W
    Input operation voltage (min)190 V
    Input operation voltage (max)478 V
    Output operation voltage (min)208 V
    Output operation voltage (max)240 V
    Efficiency90%
    Emergency Power Off (EPO)Yes
    Output voltage Total Harmonic Distortion (THD)5%
    Input current Total Harmonic Distortion (THD)5%
    Crest factor3:1
    Output power capacity10000 VA
    Total Harmonic Distortion (THD) (linear load)2%
    Total Harmonic Distortion (THD) (non-linear load)5%
    Synchronisation with mains4 Hz
    Synchronisation without mains0.05 Hz
    ECO modeYes
    Battery
    Battery typeAGM
    Off-mode chargingYes
    Battery technologyLead-Calcium (Pb-Ca)
    Cold startYes
    Automatic battery testYes
    Battery recharge time(90%)9 h
    Performance
    UPS topologyDouble-conversion (Online)
    Off-mode chargingYes
    Number of output phases1
    Number of input phases3
    LED indicatorsYes
    Surge protectionYes
    Power protection featuresUnder voltage
    Noise level60 dB
    Overload capacity (10 minutes)110%
    Overload capacity (1 minute)130%
    Temperature voltage compensationYes
    Maximum number of paralleling UPSs3
    Maintenance-freeYes
    Features
    UPS topologyDouble-conversion (Online)
    Output voltage regulation1%
    Output frequency regulation4 Hz
    Number of output phases1
    Number of input phases3
    Output power factor0.9
    Input power factor0.99
    Output power9000 W
    Input operation voltage (min)190 V
    Input operation voltage (max)478 V
    Output operation voltage (min)208 V
    Output operation voltage (max)240 V
    Efficiency90%
    Surge protectionYes
    Emergency Power Off (EPO)Yes
    Power protection featuresUnder voltage
    Output voltage Total Harmonic Distortion (THD)5%
    Noise level60 dB
    Input current Total Harmonic Distortion (THD)5%
    Crest factor3:1
    Output power capacity10000 VA
    Overload capacity (10 minutes)110%
    Overload capacity (1 minute)130%
    Total Harmonic Distortion (THD) (linear load)2%
    Total Harmonic Distortion (THD) (non-linear load)5%
    Synchronisation with mains4 Hz
    Synchronisation without mains0.05 Hz
    Temperature voltage compensationYes
    Maximum number of paralleling UPSs3
    ECO modeYes
    Maintenance-freeYes
    Input frequency50/60 Hz
    Ports & interfaces
    Emergency Power Off (EPO) connectorYes
    USB portYes
    Serial interfaceYes
    Serial interface typeRS-232
    AC outlets quantity2 AC outlet(s)
    AC outlet typesC13 coupler
    USB 2.0 ports quantity1
    RS-232 ports1
    Number of output IEC jumpers2
    Parallel ports quantity3
    Design
    Form factorTower
    LED indicatorsYes
    Product colourBlack
    SafetyEN 62040-1; EN 60950-1
    DisplayLCD
    Cooling typeActive
    Built-in fanYes
    Operational conditions
    Operating temperature (T-T)0 – 40 C
    Operating relative humidity (H-H)0 – 95%
    Operating altitude0 – 5000 m
    Technical details
    BypassHybrid, Nill
    Cooling
    Cooling typeActive
    Built-in fanYes
    Weight & dimensions
    Weight85 kg
    Width250 mm
    Height576 mm
    Depth592 mm
    Certificates
    SafetyEN 62040-1; EN 60950-1
    Other features
    Battery typeAGM
    I/O portsIntelligent slot
    BypassHybrid, Nill
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us