SKU: 698RQ000004 Categories: , , , Tag:

Salicru 698RQ000004 6kVA Online Rackmount UPS - 698RQ000004

  • Available to order.
  • ETA will be advised upon ordering or call us on 0800 978 8988 for leadtime.

£2,129.74 Ex. VAT £2,555.69 Inc. VAT

Warranty: 1 Year

All major debit and credit cards accepted.

  • Description

    Salicru’s SLC TWIN RT2 series models are uninterruptible power supplies with unrivalled electrical protection features for critical server environments. Their dual tower/rack format offers physical adaptability to any site and, together with the built-in PDU strip, provides maximum ease of connection of the loads to be protected. In addition, their unity output power factor (VA=W) increases the power density delivered and reduces the space required for the installation of the UPS.

    The LCD screen is swivel-mounted according to the mounting format chosen for ease of handling. In terms of serial communications, they feature USB, RS-232 and relay interfaces, as well as a smart slot to optionally accommodate an SNMP card, MODBUS or potential-free contacts; also available are software packages for local or virtual monitoring and management of the protected devices.

    For applications that require extended backup, additional battery modules and/or solutions with extra charger can be installed. And for applications that require redundant protection or increase the need for power, there is the option of connecting up to 3 devices in parallel.

  • Technical Data
    Power
    Output power6000 W
    Input operation voltage (min)110 V
    Input operation voltage (max)300 V
    Output operation voltage (min)208 V
    Output operation voltage (max)240 V
    Emergency Power Off (EPO)Yes
    Power factor1
    Input current Total Harmonic Distortion (THD)4%
    Output power capacity6000 VA
    Total Harmonic Distortion (THD) (linear load)1%
    Total Harmonic Distortion (THD) (non-linear load)4%
    Synchronisation with mains4 Hz
    Synchronisation without mains0.1 Hz
    Ports & interfaces
    Socket circuit breakerYes
    Emergency Power Off (EPO) connectorYes
    USB portYes
    Serial interfaceYes
    Serial interface typeRS-232
    SmartSlotYes
    AC outlets quantity6 AC outlet(s)
    AC outlet typesC13 coupler, C19 coupler, Terminal
    Power plugTerminal
    RS-232 ports1
    Parallel ports quantity1
    Current distribution portYes
    Performance
    UPS topologyDouble-conversion (Online)
    Automatic Voltage Regulation (AVR)Yes
    LED indicatorsYes
    Power protection featuresUnder current, Under voltage
    Noise level60 dB
    Overload capacity (10 minutes)110%
    Overload capacity (1 minute)130%
    Charge typeConstant current/Constant voltage
    Features
    Output frequency50/60 Hz
    UPS topologyDouble-conversion (Online)
    Automatic Voltage Regulation (AVR)Yes
    Output power6000 W
    Input operation voltage (min)110 V
    Input operation voltage (max)300 V
    Output operation voltage (min)208 V
    Output operation voltage (max)240 V
    Emergency Power Off (EPO)Yes
    Power protection featuresUnder current, Under voltage
    Power factor1
    Noise level60 dB
    Input current Total Harmonic Distortion (THD)4%
    Output power capacity6000 VA
    Overload capacity (10 minutes)110%
    Overload capacity (1 minute)130%
    Total Harmonic Distortion (THD) (linear load)1%
    Total Harmonic Distortion (THD) (non-linear load)4%
    Synchronisation with mains4 Hz
    Synchronisation without mains0.1 Hz
    Socket circuit breakerYes
    Input frequency50/60 Hz
    Battery
    Battery technologyLead-Calcium (Pb-Ca)
    Cold startYes
    Battery recharge time(90%)9 h
    Charge typeConstant current/Constant voltage
    Design
    Rack capacity4U
    Form factorRackmount/Tower
    LED indicatorsYes
    Product colourBlack
    SafetyEN 62040-1:2008
    DisplayLCD
    Cooling typeActive
    CertificationEN 62040-2:2006(C3), EN 62040-3:2011, ISO 9001, ISO 14001
    Operational conditions
    Operating temperature (T-T)0 – 40 C
    Operating relative humidity (H-H)0 – 95%
    Operating altitude0 – 2400 m
    Technical details
    Output frequency50/60 Hz
    Cooling
    Cooling typeActive
    Weight & dimensions
    Weight69 kg
    Width438 mm
    Height88 mm
    Depth600 mm
    Certificates
    SafetyEN 62040-1:2008
    CertificationEN 62040-2:2006(C3), EN 62040-3:2011, ISO 9001, ISO 14001
    Other features
    Compatible operating systemsWindows, Linux, Mac
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

  • Reviews (0)
    Product Reviews

    Reviews

    There are no reviews yet.

    Be the first to review “Salicru 698RQ000004 6kVA Online Rackmount UPS”

    Your email address will not be published.

    Company Reviews

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us