    Salicru’s SLC TWIN RT2 UPS range is a highly advanced continuity solution for the electrical protection of critical systems. It combines the most reliable double-conversion technology (AC/DC-DC/AC) on the market and boasts a unity output power factor (VA=W) to enable it to power systems with high energy requirements, while offering high operating efficiency.

    The range of power ratings from 700 VA(W) to 3,000 VA(W), it comes in a 2U, convertible to tower format, with a swivel mount LCD display, according to the needs of the facility. Also available are solutions with an extra charger and additional battery modules for applications that require greater backup.

    In terms of communications, it features an RS-232/USB interface compatible with HID protocol and a smart slot that can optionally hold an SNMP card, MODBUS or potential free contacts; also available are software packages for local or virtual monitoring and management of protected devices. Other outstanding features include: 50/60 or 60/50 Hz frequency converter, emergency stop (EPO), and programmable outputs for critical/non-critical loads.

  • Technical Data
    Power
    Output power700 W
    Input operation voltage (min)110 V
    Input operation voltage (max)300 V
    Output operation voltage (min)200 V
    Output operation voltage (max)240 V
    Emergency Power Off (EPO)Yes
    Power factor1
    Input current Total Harmonic Distortion (THD)5%
    Output power capacity700 VA
    Total Harmonic Distortion (THD) (linear load)2%
    Total Harmonic Distortion (THD) (non-linear load)4%
    Synchronisation with mains3 Hz
    Synchronisation without mains0.1 Hz
    Performance
    UPS topologyDouble-conversion (Online)
    Automatic Voltage Regulation (AVR)Yes
    Surge protectionYes
    Surge protection featuresDigital Subscriber Line (DSL), Fax, Modem
    Power protection featuresUnder current, Under voltage
    Noise level55 dB
    Overload capacity (10 minutes)110%
    Overload capacity (1 minute)130%
    Overload capacity (5 minute)130%
    Programmable socketsYes
    Charge typeI/U
    Input frequency converterYes
    Temperature voltage compensationYes
    Features
    Output frequency50/60 Hz
    UPS topologyDouble-conversion (Online)
    Automatic Voltage Regulation (AVR)Yes
    Output power700 W
    Input operation voltage (min)110 V
    Input operation voltage (max)300 V
    Output operation voltage (min)200 V
    Output operation voltage (max)240 V
    Surge protectionYes
    Surge protection featuresDigital Subscriber Line (DSL), Fax, Modem
    Emergency Power Off (EPO)Yes
    Power protection featuresUnder current, Under voltage
    Power factor1
    Noise level55 dB
    Input current Total Harmonic Distortion (THD)5%
    Output power capacity700 VA
    Overload capacity (10 minutes)110%
    Overload capacity (1 minute)130%
    Overload capacity (5 minute)130%
    Total Harmonic Distortion (THD) (linear load)2%
    Total Harmonic Distortion (THD) (non-linear load)4%
    Synchronisation with mains3 Hz
    Synchronisation without mains0.1 Hz
    Input frequency converterYes
    Temperature voltage compensationYes
    Input frequency50/60 Hz
    Ports & interfaces
    Emergency Power Off (EPO) connectorYes
    USB portYes
    Serial interfaceYes
    Serial interface typeRS-232
    SmartSlotYes
    AC outlets quantity8 AC outlet(s)
    AC outlet typesC13 coupler
    Power plugC14 coupler
    RS-232 ports1
    Ethernet LAN (RJ-45) ports2
    Programmable socketsYes
    Battery
    Battery technologyLead-Calcium (Pb-Ca)
    Battery recharge time3 h
    Cold startYes
    Charge typeI/U
    Design
    Rack capacity2U
    Form factorRackmount/Tower
    Product colourBlack
    SafetyEN 62040-1:2008
    DisplayLCD
    Cooling typeActive
    CertificationEN 62040-2:2006(C2), EN 62040-3:2011, ISO 9001, ISO 14001
    Operational conditions
    Operating temperature (T-T)0 – 40 C
    Operating relative humidity (H-H)0 – 95%
    Operating altitude0 – 2400 m
    Technical details
    Output frequency50/60 Hz
    Cooling
    Cooling typeActive
    Weight & dimensions
    Weight14.1 kg
    Width438 mm
    Height88 mm
    Depth410 mm
    Certificates
    SafetyEN 62040-1:2008
    CertificationEN 62040-2:2006(C2), EN 62040-3:2011, ISO 9001, ISO 14001
    Other features
    Compatible operating systemsWindows, Linux, Mac
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.