Salicru SLC-8000-TWIN RT2 B1 - 698CC000004
- Available to order.
- ETA will be advised upon ordering or call us on 0800 978 8988 for leadtime.
£2,377.46 Ex. VAT £2,852.95 Inc. VAT
All major debit and credit cards accepted.
- Description
Salicru’s SLC TWIN RT2 series models are uninterruptible power supplies with unrivalled electrical protection features for critical server environments. Their dual tower/rack format offers physical adaptability to any site and, together with the built-in PDU strip, provides maximum ease of connection of the loads to be protected. In addition, their unity output power factor (VA=W) increases the power density delivered and reduces the space required for the installation of the UPS.
The LCD screen is swivel-mounted according to the mounting format chosen for ease of handling. In terms of serial communications, they feature USB, RS-232 and relay interfaces, as well as a smart slot to optionally accommodate an SNMP card, MODBUS or potential-free contacts; also available are software packages for local or virtual monitoring and management of the protected devices.
For applications that require extended backup, additional battery modules and/or solutions with extra charger can be installed. And for applications that require redundant protection or increase the need for power, there is the option of connecting up to 3 devices in parallel.
- Technical Data
Model SLC Twin RT2 0.7-3kVA SLC Twin RT2 4-10kVA Technology On-line, double conversion Input Rated Voltage 200/208/220/230/240 V(1)208/220/230/240 V(2)Voltage Range 110 300 V up to 60% load 110 300 V up to 50% load Frequency 50 / 60 Hz (Auto detection) Frequency Range 10 Hz 4 Hz Total Harmonic Distortion (THDi) ?5% ?4% Output Power Factor 0.8 0.8 Rated Voltage 200/208/220/230/240 V(1)208/220/230/240 V(2)Response time 20 ms for load steps 0% 100% and voltage drop up to -5% Voltage accuracy (battery mode) 1% Total harmonic distortion (THDv) < 2% linear load /
< 4% non-linear load< 1% linear load /
< 4% non-linear loadSynchronisation With mains 3 Hz 4 Hz Without mains 0.1 Hz Permissible overload (normal mode) < 130% for 5 mins /
< 140% for 30 s< 110% for 10 mins /
< 140% for 1 minProgrammable sockets Yes, for critical /
non-critical loads (4/4)N/A Performance Normal mode ? 89 91% ? 93 94% ECO mode ? 95 97% ? 99% Parallel No Yes, up to 3 units(3)Battery Battery type Pb-Ca sealed, AGM, maintenance-free Protection Against power surges, undervoltages and alternating current components Charger Charge Type I/U (constant current/constant voltage) Recharge time 3 hours to 95% 7 9 hours to 90% Temperature voltage compensation Yes Communication Interface USB-HID / RS-232 USB / RS-232 / relay Smart slot for SNMP / potential-free contacts / MODBUS Yes Downloadable monitoring software Yes, for Windows, Linux and Mac Other Functions Cold Start Yes Emergency Stop (EPO) Yes ADSL/fax/modem transient protector Yes No Frequency converter Yes(4)Yes(5)General Operating temperature 0C +40C Relative humidity Up to 95%, non-condensing Operating altitude 2,400 masl (power degradation up to 5,000 m) Noise level at 1 metre < 50 55 dB < 58-60 dB Standards Safety EN 62040-1:2008 Electromagnetic compatibility (EMC) EN 62040-2:2006(C2) EN 62040-2:2006(C3) Operation EN 62040-3:2011 Quality and Environmental Management ISO 9001 and ISO 14001 (1) 80% power reduction for 200 or 208 V devices.
(2) 90% power reduction for 208 V devices
(3) 90% power reduction.
(4) 78% power reduction.
(5) 60% power reduction. - Onsite Maintenance
Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.
1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT
For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.
Warranty Plus Extends your warranty up to 3 years, next working day replacement Warranty Plus Extends your warranty up to 5 years, next working day replacement Intervention, Provides one preventative maintenance visit, planned visit Battery Plus, Provides replacement batteries to site, next working day replacement Warranty One Extends your warranty up to 1 year, next working day replacement 2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT
No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.
Services Included
Silver Level
Gold Level
Platinum Level
Technical Hotline 24/7 Yes Yes Yes Preventative Maintenance Yes Yes Yes Remote Monitoring 24/7 Yes Yes Yes Firmware Upgrades Yes Yes Yes Emergency Response Yes Yes Yes Labour Yes Yes Yes Parts Yes Yes Yes Monthly Event/Status Report option option option Onsite Crash Kit option option option Response Time 12 working hours 8 working hours 4 clock hours 3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT
Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.
Engineer Installation and configuration during normal hours 24×7 flexible status and remote monitoring. Encrypted communication, allowing safe offsite monitoring Alarms and events emailed and SMS texted automatically Firewall Friendly Cloud based status overview and multiple sites status on one screen Allows First Fix Response to Site 4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.
- Reviews (0)
Product Reviews
Company Reviews
Our brands
Shown below is a small selection of some of our customers we have helped through understanding clients challenges and implementing our unique approach to helping clients built around: listening to our clients, understanding the challenges they face and providing a range of options which compliments their requirements. Our aim is not to sell products but provide solutions with the help of our in house Power Consultants and Electricians.







Reviews
There are no reviews yet.