    Salicru’s SPS ADVANCE T series offers, as a UPS solution, optimum levels of efficiency and reliability for all critical devices that require power supply continuity and dependability. They come in a very compact tower format to save space in server and computer rooms. They also feature line-interactive technology to combat any fluctuations in the mains supply together with an output voltage that is always sine-wave, the highest quality possible to power all sensitive loads.

    For easier and more convenient use, they feature a display that shows all necessary information on the operation of the device and power supply (input/output voltage, % load, % battery, etc.) and a wide range of communication options through the USB interface with HID protocol, monitoring and management software (downloadable) and integrated smart slot (SNMP).

    Also noteworthy is their compatibility with current APFC (active power factor correction) power supplies.
    The power range for the SPS ADVANCE T series is: 850, 1,000, 1,500, 2,000 and 3,000 VA.

    Power
    Output voltage regulation 10%
    Output frequency regulation 1 Hz
    Output power 595 W
    Input operation voltage (min) 165 V
    Input operation voltage (max) 290 V
    Output operation voltage (max) 230 V
    Efficiency 98%
    Emergency Power Off (EPO) Yes
    Output voltage Total Harmonic Distortion (THD) 5%
    Output power capacity 850 VA
    Efficiency (Stabiliser mode (AVR)) 92%
    Efficiency (Battery mode) 80%
    Battery
    Battery type AGM
    Battery technology Lead-Calcium (Pb-Ca)
    Cold start Yes
    Automatic battery test Yes
    Battery recharge time(90%) 4 h
    Performance
    Audible alarm modes Fault, Low battery alarm, Overload alarm
    UPS topology Line-Interactive
    Waveform Pure sine
    Automatic Voltage Regulation (AVR) Yes
    LED indicators Yes
    Surge protection Yes
    Power protection features Overdischarge, Overload, Short circuit
    Noise level 45 dB
    Audible alarm(s) Yes
    Overload capacity – line mode (1 minute) 110%
    Overload capacity – battery mode (1 minute) 110%
    Maintenance-free Yes
    Features
    Output frequency 50/60 Hz
    Audible alarm modes Fault, Low battery alarm, Overload alarm
    UPS topology Line-Interactive
    Waveform Pure sine
    Output voltage regulation 10%
    Output frequency regulation 1 Hz
    Automatic Voltage Regulation (AVR) Yes
    Output power 595 W
    Input operation voltage (min) 165 V
    Input operation voltage (max) 290 V
    Output operation voltage (max) 230 V
    Efficiency 98%
    Surge protection Yes
    Emergency Power Off (EPO) Yes
    Power protection features Overdischarge, Overload, Short circuit
    Output voltage Total Harmonic Distortion (THD) 5%
    Noise level 45 dB
    Audible alarm(s) Yes
    Output power capacity 850 VA
    Overload capacity – line mode (1 minute) 110%
    Overload capacity – battery mode (1 minute) 110%
    Efficiency (Stabiliser mode (AVR)) 92%
    Efficiency (Battery mode) 80%
    Maintenance-free Yes
    Input frequency 50/60 Hz
    Ports & interfaces
    Emergency Power Off (EPO) connector Yes
    USB port Yes
    Serial interface Yes
    Serial interface type RS-232
    SmartSlot Yes
    AC outlets quantity 6 AC outlet(s)
    AC outlet types C13 coupler
    Power plug C14 coupler
    USB 2.0 ports quantity 1
    RS-232 ports 1
    Number of output IEC jumpers 6
    Design
    Form factor Tower
    LED indicators Yes
    Product colour Black
    Safety EN 62040-1
    Display LCD
    Cooling type Active
    Certification EN 62040-2, EN 62040-3, ISO-9001, ISO-14001
    Built-in fan Yes
    Operational conditions
    Operating temperature (T-T) 0 – 40 C
    Operating relative humidity (H-H) 0 – 95%
    Operating altitude 0 – 2400 m
    Technical details
    Output voltage 230 V
    Output frequency 50/60 Hz
    Cooling
    Cooling type Active
    Built-in fan Yes
    Weight & dimensions
    Weight 11.8 kg
    Width 140 mm
    Height 191 mm
    Depth 327 mm
    Certificates
    Safety EN 62040-1
    Certification EN 62040-2, EN 62040-3, ISO-9001, ISO-14001
    Other features
    Output voltage 230 V
    Battery type AGM
    Compatible operating systems Windows, Linux, Mac

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us