    Symmetra PX Features & Benefits

    Total cost of Ownership

    Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.

    Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.

    Fully-rated power kVA equals kW Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.

    5×8 Start-up service included Required for full coverage of factory warranty

    Manageability

    Audible alarms Provides notification of changing utility power and UPS power conditions

    LED status indicators Quickly understand unit and power status with visual indicators.

    Integrates with StruxureWare Data Center Expert An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

    Sustainability

    EU CoC for UPS Ensures that UPSs sold in the EU are highly efficient

    Agility

    SmartSlot Customize UPS capabilities with management cards.

    Scalable power capacity Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.

    Programmable frequency Ensures compatibility with different input frequencies.

    Availability

    Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

    Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures.

    Network manageable Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.

    Modular design Provides scalability, N+1 redundancy, fast serviceability, and reduced maintenance requirements via self-diagnosing, swappable, and field-replaceable modules.

    User-replaceable power modules Enables simple upgrades and replacements of the Power Modules.

    User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

    Swappable power modules Allows quick addition of power capacity or replacement of existing power modules. Installed modules are automatically recognized by the system.

    Battery modules connected in parallel Delivers higher availability through redundant batteries.

    Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.

    Configurable for N+1 internal redundancy Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

    Output

    Max Configurable Power (Watts) 500.0kWatts
    / 500.0kVA
    Output Voltage Distortion Less than 2 %
    Output Frequency (sync to mains) 50 Hz +/- 0.1 % For 50 Hz nominal Unsynchronised, 50 Hz Sync to mains, 60 Hz +/- 0.1 % For 60 Hz nominal Unsynchronised, 60 Hz Sync to mains
    Other Output Voltages 415 V
    Topology Double conversion online
    Waveform type Sine wave
    Overload Operation 10 minutes at 125% and 60 seconds at 150%
    Output Voltage THD < 2% linear load and < 3% non-linear load
    Output Voltage Tolerance +/- 1% static and +/- 5% at 100% load step
    Transfer Time 2 ms typical
    Bypass Built-in maintenance bypass, Built-in static bypass

    Input

    Input frequency 40 – 70 Hz Auto-sensing
    Input voltage range for main operations 340 – 460 (400 V), 408 – 552 (480 V)V
    Input Total Harmonic Distortion Less than 5 % for full load
    Type of Input Protection Required 3-pole circuit breaker
    Other Input Voltages 415 V
    Maximum Short Circuit Withstand (Icw) 50.0kAmps
    Input Power Factor at Full Load 0.99

    Batteries & Runtime

    Battery type VRLA
    Included Battery Modules 20
    Typical recharge time 3.5hour(s)
    Battery Slots Empty 24
    RBC Quantity 6
    Battery Charge Power (Watts) 29.538kWatts
    Extendable Run Time 1
    Efficiency in Battery Operation 96.0 %
    Overload Operation 10 minutes at 125% and 60 seconds at 150%
    Runtime View Here

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.