    Symmetra PX Features & Benefits

    Total cost of Ownership

    Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.

    Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.

    Fully-rated power kVA equals kW Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.

    5×8 Start-up service included Required for full coverage of factory warranty

    Manageability

    Audible alarms Provides notification of changing utility power and UPS power conditions

    LED status indicators Quickly understand unit and power status with visual indicators.

    Integrates with StruxureWare Data Center Expert An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

    Sustainability

    EU CoC for UPS Ensures that UPSs sold in the EU are highly efficient

    Agility

    SmartSlot Customize UPS capabilities with management cards.

    Scalable power capacity Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.

    Programmable frequency Ensures compatibility with different input frequencies.

    Availability

    Redundant Intelligence Modules Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

    Power Modules connected in parallel Enhances availability by allowing immediate, seamless recovery from isolated module failures.

    Network manageable Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.

    Modular design Provides scalability, N+1 redundancy, fast serviceability, and reduced maintenance requirements via self-diagnosing, swappable, and field-replaceable modules.

    User-replaceable power modules Enables simple upgrades and replacements of the Power Modules.

    User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

    Swappable power modules Allows quick addition of power capacity or replacement of existing power modules. Installed modules are automatically recognized by the system.

    Battery modules connected in parallel Delivers higher availability through redundant batteries.

    Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault.

    Configurable for N+1 internal redundancy Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

  • Technical Data

    Output

    Max Configurable Power (Watts) 160.0kWatts
    / 160.0kVA
    Neutral Output Current 240A
    Output Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
    Efficiency at Full Load 95.0 %
    Output Voltage Distortion Less than 2 %
    Output Frequency (sync to mains) 50 Hz +/- 0.1 % For 50 Hz nominal Unsynchronised, 50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz Sync to mains
    Topology Double conversion online
    Waveform type Sine wave
    Overload Operation 10 minutes at 125% and 60 seconds at 150%
    Output Voltage THD < 2% for 0 to 100% linear load and < 5% for full non-linear load
    Output Voltage Tolerance +/- 1% static and +/- 5% at 100% load step
    Bypass Built-in static bypass

    Input

    Input frequency 40 – 70 Hz
    Input voltage range for main operations 340 – 477V
    Efficiency at Full Load 95.0 %
    Input Total Harmonic Distortion Less than 5 % for full load
    Maximum Short Circuit Withstand (Icw) 30.0kAmps
    Input Power Factor at Full Load 0.99

    Batteries & Runtime

    Battery type External battery system
    Replacement BatterySYPBV96K160HA
    Efficiency in Battery Operation 94.0 %

    Communications & Management

    Interface Port(s) DB-9 RS-232, SmartSlot
    Control panel Multifunction LCD status and control console
    Audible Alarm Alarm when on battery : distinctive low battery alarm : configurable delays
    Emergency Power Off (EPO) Yes
    Available SmartSlot™ Interface Quantity 2

    Physical

    Maximum Height 1991MM, 199.1CM
    Maximum Width 600MM, 60.0CM
    Maximum Depth 1070MM, 107.0CM
    Net Weight 496.0KG
    Shipping weight 547.0KG
    Shipping Height 2140MM, 214.0CM
    Shipping Width 848MM, 84.8CM
    Shipping Depth 1210MM, 121.0CM
    Color Black

    Environmental

    Operating Temperature 0 – 40 °C
    Operating Relative Humidity 0 – 95 %
    Operating Elevation 0 – 1015.9meters
    Storage Temperature -15 – 40 °C
    Storage Relative Humidity 0 – 95 %
    Storage Elevation 0 – 15240meters
    Audible noise at 1 meter from surface of unit 63.0dBA
    Online thermal dissipation 17244.0BTU/hr
    Protection Class IP20, NEMA 1

    Conformance

    Approvals EN 50091-1, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, ISO 14001, ISO 9001, VFI-SS-111
    Standard warranty 1 year on-site repair or replace with factory authorized Start-Up

    General

    Bypass Connection 5 wire (3P + N + E)
    Bypass Protection Device 250.0
    Max Bypass Input Current 250.0A
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

  • Downloads

Customers also bought…

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us