Gone in a FLASH
Black Friday Deals

Tripp Lite 1.8kW Single-Phase Basic PDU, 120V Outlets (13 5-15R), 5-15P, 15ft Cord, 1U Rack-Mount - PDU1215
This product has been Discontinued
- Description
Tripp Lite’s PDU1215 1.8kW 15A Single-Phase Basic Power Distribution Unit (PDU) is a dependable, space-saving, cost-effective way to deliver 120V power to wiring closets, server rooms and equipment racks from a UPS system, generator or utility wall outlet in high-density IT environments. With 13 NEMA 5-15R outlets (1 front, 12 rear), a rugged all-metal housing and a switchless design to prevent accidental shutoff, the PDU1215 is a basic power distribution unit for networking, PC systems, telecommunications, audio/video, security, sound reinforcement, and other similar applications. The PDU1215 includes hardware for 1U rackmount installation. Other mounting configurations include vertical 0U rackmount (with compatible racks and PDUSIDEBRKT accessory, sold separately), wall-mount, workbench and under-counter installations. – 1.8kW 15A 120V single phase Basic Power Distribution Unit / PDU – 1U horizontal 19 inch rackmount form factor installs in one rack space – NEMA 5-15P 15A 120v input plug with 15 ft. / 4.5m line cord – 13 NEMA 5-15R outlets (1 front / 12 rear) – Adjustable mounting brackets enable installation in 2 or 4 post racks, plus additional support for wallmount and under-counter mounting – Mounting ears are reversible for front or rear facing rackmount installation – Optional PDUSIDEBRKT enable 0U vertical installation in compatible racks – Back-panel grounding lug – RoHS-compliant
- Technical Data
Design PDU types Basic Mounting Horizontal Product colour Black Certification UL60950-1/CSA-C22.2 Rack capacity 1U Housing material Metal Ports & interfaces AC outlets quantity 13 AC outlet(s) AC outlet types NEMA 5–15R Power plug NEMA 5–15P I/O ports 13 x NEMA 5-15R Features Cable length 4.57 m Certification UL60950-1/CSA-C22.2 Ergonomics Cable length 4.57 m Power Nominal input voltage 100-127 V Nominal output voltage 100-127 V Maximum current 15 A Weight & dimensions Dimensions (WxDxH) 445 x 114 x 44.4 mm Weight 2.36 kg Width 508 mm Depth 114.3 mm Height 50.8 mm Package width 518.2 mm Package depth 236.2 mm Package height 55.9 mm Package weight 2.39 kg Packaging data Package width 518.2 mm Package depth 236.2 mm Package height 55.9 mm Package weight 2.39 kg Operational conditions Storage temperature (T-T) -15 – 50 °C Operating altitude 0 – 3000 m Technical details Sustainability certificates RoHS Master (outer) case GTIN (EAN/UPC) 10037332116724 Logistics data Master (outer) case width 53.1 cm Master (outer) case length 34.5 cm Master (outer) case height 25.6 cm Master (outer) case gross weight 14 kg Products per master (outer) case 6 pc(s) Country of origin China - Onsite Maintenance
Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.
1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT
For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.
Warranty Plus Extends your warranty up to 3 years, next working day replacement Warranty Plus Extends your warranty up to 5 years, next working day replacement Intervention, Provides one preventative maintenance visit, planned visit Battery Plus, Provides replacement batteries to site, next working day replacement Warranty One Extends your warranty up to 1 year, next working day replacement 2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT
No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.
Services Included
Silver Level
Gold Level
Platinum Level
Technical Hotline 24/7 Yes Yes Yes Preventative Maintenance Yes Yes Yes Remote Monitoring 24/7 Yes Yes Yes Firmware Upgrades Yes Yes Yes Emergency Response Yes Yes Yes Labour Yes Yes Yes Parts Yes Yes Yes Monthly Event/Status Report option option option Onsite Crash Kit option option option Response Time 12 working hours 8 working hours 4 clock hours 3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT
Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.
Engineer Installation and configuration during normal hours 24×7 flexible status and remote monitoring. Encrypted communication, allowing safe offsite monitoring Alarms and events emailed and SMS texted automatically Firewall Friendly Cloud based status overview and multiple sites status on one screen Allows First Fix Response to Site 4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.
Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.
Our brands
Shown below is a small selection of some of our customers we have helped through understanding clients challenges and implementing our unique approach to helping clients built around: listening to our clients, understanding the challenges they face and providing a range of options which compliments their requirements. Our aim is not to sell products but provide solutions with the help of our in house Power Consultants and Electricians.