    • Description

      Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. – Switched 30A 208/240V PDU, 2U horizontal rackmount format – Reports voltage, frequency & load level via ethernet interface – Visual current meter, Reversible housing – NEMA L6-30P input plug with attached 12 ft. / 3.6m line cord – 16 switched C13 outlets with cord retention brackets – Temperature, humidity and contact closure monitoring options – Rackmount PDU – Installable 2U mounting brackets – 30A 208/240V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 24A continuous) – Attached L6-30P 208/240V single phase input, 12 ft. / 3.6m input cord – 2U horizontal rackmount form factor – 16 switched c13 outlets – Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis – Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets – Network interface provides PDU control and data regarding input voltage and total output load level in amps – Digital display continuously reports output load in amps in 3 segments (load bank 1, load bank 2, total) – Supports user-specified alarm notification thresholds – In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors – DHCP/Manual configuration support – 10/100 Mbps auto-sensing – Real-time clock backup maintains the time of day and date even if the PDU is unpowered – Tiered access privileges allow an administrator and a guest to login via web browser – Alert notifications via email or SNMP traps offer immediate event notification – Firmware upgrade ability supports future product enhancements – Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols – Fully compatible with FREE PowerAlert Network Management System / NMS Software – 2U horizontal rack installation supported in 2 or 4 post racks with included mounting brackets – Mounting brackets support wall-mount and under-counter installation in many applications – Included cord retention brackets

    • Technical Data
      Design
      PDU typesSwitched
      MountingHorizontal
      Product colourBlack
      CertificationUL 60950-1, Class A, NOM
      Rack capacity2U
      Housing materialMetal
      Ports & interfaces
      AC outlets quantity16 AC outlet(s)
      AC outlet typesC13 coupler
      Power plugNEMA L6-30P
      Features
      Cable length3.6 m
      CertificationUL 60950-1, Class A, NOM
      Ergonomics
      Cable length3.6 m
      Power
      Nominal input voltage200-240 V
      Nominal output voltage200-240 V
      Maximum current30 A
      AC input frequency50 – 60 Hz
      Weight & dimensions
      Dimensions (WxDxH)445 x 317.5 x 89 mm
      Weight6.21 kg
      Width444.5 mm
      Depth317.5 mm
      Height88.9 mm
      Package width424.2 mm
      Package depth497.8 mm
      Package height198.1 mm
      Package weight7.71 kg
      Packaging data
      Package width424.2 mm
      Package depth497.8 mm
      Package height198.1 mm
      Package weight7.71 kg
      Operational conditions
      Storage temperature (T-T)-15 – 50 °C
      Operating altitude0 – 3000 m
      Technical details
      Sustainability certificatesRoHS
      Logistics data
      Products per master (outer) case1 pc(s)
      Country of originTaiwan
    • Onsite Maintenance

      Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

      1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

      For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

      Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
      Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
      Intervention, Provides one preventative maintenance visit, planned visitGreen tick
      Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
      Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

      2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

      No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

      Services Included

      Silver Level

      Gold Level

      Platinum Level

       

      Technical Hotline 24/7YesYesYesGreen tick
      Preventative MaintenanceYesYesYesGreen tick
      Remote Monitoring 24/7YesYesYesGreen tick
      Firmware UpgradesYesYesYesGreen tick
      Emergency ResponseYesYesYesGreen tick
      LabourYesYesYesGreen tick
      PartsYesYesYesGreen tick
      Monthly Event/Status ReportoptionoptionoptionGreen tick
      Onsite Crash KitoptionoptionoptionGreen tick
      Response Time12 working hours8 working hours4 clock hoursGreen tick

      3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

      Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

      Engineer Installation and configuration during normal hoursGreen tick
      24×7 flexible status and remote monitoring.Green tick
      Encrypted communication, allowing safe offsite monitoringGreen tick
      Alarms and events emailed and SMS texted automaticallyGreen tick
      Firewall FriendlyGreen tick
      Cloud based status overview and multiple sites status on one screenGreen tick
      Allows First Fix Response to SiteGreen tick

      4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

      Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

      Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    We are here when you need us most

    As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

    Contact us