    • AVRX550U ultra-compact 230V line interactive UPS offers complete AC power protection from blackouts, brownouts and transient surges
    • 550VA / 300 watt UPS output capacity
    • Uninterruptible Power Supply / UPS operation maintains battery-derived AC output during blackouts to prevent data loss and system downtime for connected equipment
    • Built-in USB port enables data-saving unattended shutdown when used with Tripp Lite’s PowerAlert software, available via FREE
    • HID-compliant USB port also enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
    • Automatic Voltage Regulation / AVR corrects extended brownouts and overvoltages from 179 to 282V, without using battery power
    • 5.1runtime at 50% load
    • Up to 10runtime for a small desktop computer system consug 80 watts continuous
    • 6 total C17 outlets; Includes two 2m C17 to C16 power cables
    • 3 UPS battery backup outlets, plus 3 additional surge-only outlets
    • C16 inlet supports a variety of site specific input cordsets
    • Network grade AC surge protection is available from all outlets
    • Built-in data line surge suppression protects a single dialup or DSL line
    • Supports Tripp Lite’s Watchdog system service to restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment, ideal for unattended kiosk applications
    • Built-in grounding lug
    • Hot swappable user battery replacement supported via easy access battery access door
    • Optional PDUBHV10 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
    • Space saving, ultra-compact housing with support for wall-mount, desktop or floor placement
  • Technical Data

     

    OVERVIEW
    UPC Code037332123473
    UPS TypeLine-Interactive
    INPUT
    Rated input current (Maximum Load)10A
    Nominal Input Voltage(s) Supported230V AC
    UPS Input Connection TypeC14 inlet
    UPS Input Connection DescriptionAttached 15cm line cord with C14 inlet. The C14 inlet accepts user-supplied AC power cord with country specific plug
    UPS Input Cord Length (ft.)0.5
    UPS Input Cord Length (m)0.2
    Input PhaseSingle-Phase
    OUTPUT
    Output Volt Amp Capacity (VA)550
    Output Watt Capacity (Watts)300
    Nominal Voltage Details230V nominal output in battery mode
    Frequency Compatibility50 / 60 Hz
    Frequency Compatibility DetailsAutomatic frequency selection
    Output Voltage Regulation (Line Mode)+8%, -21%
    Output Voltage Regulation (Battery Mode)+/- 5%
    Included Output Power CablesIncludes 2 C13 to C14 output power cables
    UPS Output Receptacles (Surge Suppression Only)3 UPS outlets, 3 surge-only outlets
    Hot-Swap PDU optionsPDUBHV10 (2U / 8 C13 outlets)
    Output AC Waveform (AC Mode)Sine wave
    Output AC Waveform (Battery Mode)PWM sine wave
    Nominal Output Voltage(s) Supported220V; 230V; 240V
    Output Receptacles(6) C13
    Individually Controllable Load Banks  No
    BATTERY
    Battery TypeValve Regulated Lead Acid (VRLA)
    Half Load Runtime (min.)  5.1 min. (150w)
    Expandable RuntimeNo
    DC System Voltage (VDC)12
    Battery AccessBattery access door
    Internal UPS Replacement Battery CartridgeIMPORTANT BATTERY REPLACEMENT INFORMATION > If the original battery inside your AVRX550U UPS has a rating of 12V 3.6AH, please order Tripp Lite  RBC36H  (quantity 1) replacement battery; If the original battery inside your AVRX550U UPS has a rating of 12V 5AH, please contact Tripp Lite for assistance
    Battery Replacement DescriptionHot-swappable, user replaceable batteries
    VOLTAGE REGULATION
    Voltage Regulation DescriptionAutomatic voltage regulation (AVR) maintains line power operation with an input voltage range of 159 to 282VAC
    Overvoltage Correction  Input voltages between 245 and 282 are reduced by 12%
    Undervoltage Correction  Input voltages between 159 and 205 are boosted by 14%
    USER INTERFACE, ALERTS & CONTROLS
    SwitchesCombination switch controls on/off power status and self-test operation
    Audible AlarmAudible alarm indicates power-failure and overload status
    LED Indicators2 LEDs indicate power status and overload/check battery status
    SURGE / NOISE SUPPRESSION
    UPS AC Suppression Joule Rating320
    UPS AC Suppression Response TimeInstantaneous
    UPS Dataline Suppression1 line TEL/DSL (1 in / 1 out)
    EMI / RFI AC Noise Suppression  Yes
    PHYSICAL
    Primary Form FactorDesktop
    Installation Form Factors Supported with Included AccessoriesTower; Ultra-compact desktop; Wallmount
    Primary UPS Depth (mm)147
    Primary UPS Height (mm)89
    Primary UPS Width (mm)279
    Shipping Dimensions (hwd / cm)11.68 x 34.04 x 22.35
    Shipping Weight (kg)4.63
    UPS Housing MaterialABS
    UPS Power Module Dimensions (hwd, cm)8.89 x 27.94 x 14.73
    UPS Power Module Weight (kg)3.86
    ENVIRONMENTAL
    Operating Temperature Range+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
    Storage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
    Relative Humidity0 to 95%, non-condensing
    AC Mode BTU / Hr. (Full Load)  54
    AC Mode Efficiency Rating (100% Load)95%
    COMMUNICATIONS
    PowerAlert SoftwareFor local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
    Communications CableUSB interface cable included
    WatchDog CompatibilitySupports Watchdog application, OS and hard-reboot restart options for remote applications
    Network UPS Tools CompatibilityNUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
    Network Management Card DescriptionNetwork management not supported
    Communications InterfaceUSB (HID enabled)
    LINE / BATTERY TRANSFER
    Transfer Time  4 milliseconds
    Low Voltage Transfer to Battery Power (Setpoint)159
    High Voltage Transfer to Battery Power (Setpoint)282
    FEATURES & SPECIFICATIONS
    Grounding LugIncluded
    Cold Start (Startup in Battery Mode During a Power Failure)Cold-start operation supported
    High Availability UPS Features  Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection
    Green Energy-Saving FeaturesGreater than 95% efficiency – GREEN UPS
    STANDARDS & COMPLIANCE
    UPS CertificationsCE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Meets FCC Part 15 Category B (EMI); ROHS (Restriction of Hazardous Substances)
    Certification DetailsEN62040
    WARRANTY
    Product Warranty Period (International)2-year limited warranty
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

  • Downloads
  • Reviews (0)
    Product Reviews

    Reviews

    There are no reviews yet.

    Be the first to review “Tripp Lite AVR Series 230V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port, C17 Outlets”

    Your email address will not be published.

    Company Reviews

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us