SKU: N484-3M8-LC12 Categories: , Brand: Tripp Lite

Tripp Lite N484-3M8-LC12 40/100Gb Breakout Cassette, 40Gb to 4 x 10Gb, 100Gb to 4 x 25Gb, (x3) 8-Fiber MTP/MPO to (x12) LC Duplex, Type-B Polarity

  • Order Now. Speak to a Specialist. Call 0800 978 8988.
  • ETA will be advised upon ordering or call us.

£385.09 Ex VAT
£462.11 Inc VAT

Delivery Costs

Find below some of our pricing costs for Critical Power Supplies online store.

England, Wales and Scottish Lowlands

2 to 3 Working Days - £4.99.
Next Working Day - £9.99.
Pre Noon, Pre 10:30am - Contact Us.

Scottish Lowlands Postcodes
AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9

Highlands, Northern Ireland, Channel Islands and Ireland

  • Scottish Highlands
    3 to 5 Working Days - £20

    Scottish Highlands Postcodes
    AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4

  • Northern Ireland
    3 to 5 Working Days - £50

  • Channel Islands
    3 to 5 Working Days - £25

  • Ireland
    5 to 7 Working Days - £99

  • Western Europe
    5 to 7 Working Days - £150 DAP
    DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.

Purchase this item and get 3850 Points - equivalent to the value of £3.85
Add to Wishlist

All major debit and credit cards accepted.

  • Description

    The N484-3M8-LC12 40/100Gb to 10/25Gb Breakout Cassette works in tandem with Tripp Lite’s N484-01U or N484-00U chassis to connect 12 LC duplex fiber cables with three 8-fiber MTP/MPO connections in high-density network applications. It’s compatible with recommended Tripp Lite cabling, including the N820-, N821-, N844-, N845- and N858 Series. Its 8-fiber MTP ports are Polarity B, optimized for parallel optics and Base-8 connectivity. The cassette’s modular design installs easily in the N484-01U and N484-00U chassis with no tools required. Just insert the cassette into the chassis, and screw in its retention clips to secure it. Plug LC patch cables, such as Tripp Lite’s N820-01M-T cables, into the cassette using the cable’s convenient push/pull tabs. Up to four N484-3M8-LC12 cassettes fit in the N484-01U 1U enclosure panel, and one cassette fits in the N484-00U 0U sleeve. Dust tabs protect unused ports from potential damage. The N484-3M8-LC12 complies with IEEE 802.3ae (10 GbE) and ANSI T11.2 (Fibre Channel) requirements. Supports 40 GbE internally using OM4 fiber optic cable. Base-8 Fiber compatible with both QSFP+ 40GBASE-SR4 to SFP+ 10GBASE-SR and QSFP28 100GBASE-SR4 to SFP28 25GBASE-SR connections. Ideal for QSFP fabric switches that use eight out of 12 available MTP fibers for four-lane parallel optics to 40 GB, allowing all 12 LC duplex cassette ports to be used. Maximum insertion loss of 0.35 dB falls well under the IEEE 802.3ae maximum channel loss specification of <25 dB. This cassette also supports devices of varying speeds, including 10Gb, 25Gb, 40Gb and 100Gb network equipment. Elegant, Simple Solution for 40Gb to 10Gb, or 100Gb to 25Gb, LC Cable Connections High-density fiber cassette for use with Tripp Lite N484-01U and N484-02U fiber enclosure panels Connect up to twelve LC duplex fiber cables with three 8-fiber MTP/MPO connections Ideal for use with QSFP fabric switches to support 4 lanes parallel to 40 GB Supports 40 GbE internally using OM4 fiber optic cable Base-8 Fiber compatible with both QSFP+ 40GBASE-SR4 to SFP+ 10GBASE-SR and QSFP28 100GBASE-SR4 to SFP28 25GBASE-SR connections 8-fiber MTP ports are Polarity B, optimized for parallel optics and Base-8 connectivity Designed Specifically for Use with Tripp Lite Cabling Guaranteed compatibility with recommended Tripp Lite cables, including N820-, N821-, N844-, N845- and N858 Series Simple Fiber Installations Save Time and Money Easy installation with no tools required Installs neatly in N484-00U 0U chassis Install up to 4 cassettes in N484-01U 1U enclosure panel Easy to Modify, Upgrade or Expand Fiber Infrastructure By Adding or Swapping Cassettes Complies with IEEE 802.3ae (10 GbE) and ANSI T11.2 (Fibre Channel) requirements 0.35 dB maximum insertion loss falls under IEEE 802.3ae maximum channel loss spec of <25 dB Supports devices of varying speeds, including 10Gb, 25Gb, 40Gb and 100Gb network equipment Premium Construction for Optimal Performance Heavy-duty cold-rolled steel construction Factory-terminated connectors reduce time and labor Dust caps protect unused ports

  • Technical Data
    Network
    Ethernet interface type40 Gigabit Ethernet
    Maximum data transfer rate40000 Mbit/s
    Ports quantity12
    Networking standardsIEEE 802.3ae
    Connector(s)MTP
    Features
    Product colourBlack
    Technical details
    Package width195.6 mm
    Package height40.6 mm
    Networking standardsIEEE 802.3ae
    Design
    Product colourBlack
    Colour
    Product colourBlack
    Weight & dimensions
    Width111.8 mm
    Weight360 g
    Height35.6 mm
    Depth94 mm
    Package weight440 g
    Package width195.6 mm
    Package height40.6 mm
    Packaging data
    Package weight440 g
    Package depth149.9 mm
    Package width195.6 mm
    Package height40.6 mm
    Logistics data
    Products per pallet1 pc(s)
    Master (outer) case gross weight4.58 kg
    Products per master (outer) case10 pc(s)
    Master (outer) case width39.6 cm
    Master (outer) case length22.6 cm
    Master (outer) case height16 cm
    Master (outer) case GTIN (EAN/UPC)10037332191363
    Country of originChina
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us