SKU: PDUMH20HVATS Categories: , ,

Tripp Lite PDUMH20HVATS 3.8kW 200–240V Single-Phase ATS/Local Metered PDU - 8 C13 and 2 C19 Outlets, Dual C20 Inlets, 12 ft. Cords, 1U, TAA - PDUMH20HVATS

  • Available to order.
  • ETA will be advised upon ordering or call us on 0800 978 8988 for leadtime.

£374.13 Ex. VAT £448.96 Inc. VAT

Warranty: 1 Year

All major debit and credit cards accepted.

  • Description

    Single-Phase 20A ATS PDU Distributes and Monitors Network-Grade Power in Real Time This local metered PDU provides real-time local reporting of the total load level via its built-in digital current meter. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMH20HVATS features eight C13 and two C19 200–240V outlets for connecting equipment. Outlets are factory-programmed for sequential turn-on at 250-millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction at startup. Switches from Primary to Secondary Power Source in Milliseconds Dual 12-foot (3.7-meter) power cables with C20 inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources. Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 2–5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source. Digital Load Meter Helps Prevent Potentially Expensive Overloads A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low. Mounts into 1U of Rack Space Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. TAA-Compliant for GSA Schedule Purchases The PDUMH20HVATS is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

  • Technical Data
    Design
    TypeSingle-phase
    PDU typesMetered, Switched
    MountingHorizontal
    DisplayLED
    Product colourBlack
    Rack capacity1U
    Housing materialMetal
    Ports & interfaces
    AC outlets quantity10 AC outlet(s)
    AC outlet typesC13 coupler, C19 coupler
    Power plugC20 coupler
    Serial ports quantity1
    Features
    Cable length3.66 m
    LED indicatorsYes
    Ergonomics
    Cable length3.66 m
    LED indicatorsYes
    DisplayLED
    Power
    Maximum power3840 W
    Nominal input voltage208 – 240 V
    Nominal output voltage200 – 240 V
    Maximum current20 A
    AC input frequency50/60 Hz
    Weight & dimensions
    Weight4.69 kg
    Width440.2 mm
    Depth375.2 mm
    Height43.7 mm
    Package width528.3 mm
    Package depth589.3 mm
    Package height134.6 mm
    Package weight7.53 kg
    Packaging data
    Package width528.3 mm
    Package depth589.3 mm
    Package height134.6 mm
    Package weight7.53 kg
    Packaging content
    Cables includedAC
    ManualYes
    Rack mount kitYes
    Operational conditions
    Storage temperature (T-T)-30 – 50 °C
    Operating relative humidity (H-H)5 – 95%
    Technical details
    Sustainability complianceYes
    Sustainability certificatesRoHS
    Logistics data
    Master (outer) case width52.8 cm
    Master (outer) case length58.9 cm
    Master (outer) case height13.7 cm
    Master (outer) case gross weight8.07 kg
    Products per master (outer) case1 pc(s)
    Country of originTaiwan
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

We are here when you need us most

As a client of Critical Power Supplies you can expect 24×7 support whether on the phone, email or on site because we always deliver on our promise to keep you operational and your satisfaction is paramount to everything we do.

Contact us