Gone in a FLASH

Black Friday Deals

SKU: SUINT1000LCD2U Categories: , Brand: Tripp Lite Tag:

Tripp Lite 208/230V 1000VA 900W Double-Conversion UPS - 6 Outlets, Extended Run, Card Slot, LCD, USB, DB9, 2U - SUINT1000LCD2U

  • Available to pre-order.
  • ETA will be advised upon ordering or call us on 0800 978 8988 for leadtime.

£539.86 Ex VAT
£647.83 Inc VAT

Delivery Costs

Find below some of our pricing costs for Critical Power Supplies online store.

England, Wales and Scottish Lowlands

2 to 3 Working Days - £4.99.
Next Working Day - £9.99.
Pre Noon, Pre 10:30am - Contact Us.

Scottish Lowlands Postcodes
AB1 - AB3, AB23, AB30 - AB36, AB41 - AB45, AB51 - AB55, DD4, DD7, DD8, DD11, FK17, G84, PA20 - PA33, PA35 - PA37, PA41 - PA49, PA60 - PA68, PA70 - PA78, FK10, DG1 - DG14, DG16, DD1, DD2, DG7, KA1 - KA30, PA17, G60 - G62, G64, G66, G81, EH21, EH31 - EH36, EH39, EH40 - EH42, G46, G77, G78, PA1, PA3 - PA10, PA12, EH1 - EH10, EH12 - EH17, EH21, EH28, EH29, FK1 - FK6, DD6, KY1 - KY12, KY14 - KY16, G1 - G5, G9, G11, G12, G14, G15, G20, G21, G31, G32, G40 - G43, G45, G51, G53, G76, IV1 - IV28, IV40 - IV49, IV51 - IV56, KW1 - KW3, KW5 - KW14, PA39, PA40, PH19 - PH25, PH30 - PH44, PA10, PA13, PA15, PA16, PA18, PA19, EH10, EH18, EH19, EH23 - EH26, EH37, AB38, AB56, IV30 - IV32, IV36, EH46, G33, G67 - G69, G71 - G75, ML1 - ML11, KW1, KW15 - KW17, PH1 - PH10, PH13 - PH18, EH26, EH38, EH43 - EH45, TD1 - TD12, TD14, TD15, ZE1 - ZE3, FK6, G63, EH27, EH47 - EH49, EH52 - EH54, HS1 - HS9

Highlands, Northern Ireland, Channel Islands and Ireland

  • Scottish Highlands
    3 to 5 Working Days - £20

    Scottish Highlands Postcodes
    AB32, AB36 - AB38, AB40 - AB42, AB55, AB56, FK17 - FK99, G83, HS1 - HS9, IV1 - IV29, IV33 - IV63, KA27, KA28, KY1 - KY16, KW1 - KW18, PA20 - PA49, PA60 - PA78, PH17 - PH26, PH30 - PH44, PH49, PH50, ZE1 - ZE4

  • Northern Ireland
    3 to 5 Working Days - £50

  • Channel Islands
    3 to 5 Working Days - £25

  • Ireland
    5 to 7 Working Days - £99

  • Western Europe
    5 to 7 Working Days - £150 DAP
    DAP / Delivered at Place - The seller is deemed to have delivered when the goods are placed at the disposal of the buyer on the arriving means of transport and ready for unloading at the named place of destination. Under DAP terms, the buyer is liable for the freight insurance, import taxes, customs brokerage, and any expenses incurred to unload the cardo from the container at the final destination.

Purchase this item and get 5398 Points - equivalent to the value of £5.40
Add to Wishlist

All major debit and credit cards accepted.

  • Description
    Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss
    This 200/208/220/230/240V 50/60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in online and battery modes. Featuring a 900W capacity, high 0.9 power factor, 627 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time to battery mode in on-line double-conversion mode, the SmartOnline? SUINT1000LCD2U double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment.

     

    Set Power Strategies to Reflect Your Protection Priorities
    Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from five selectable strategies: Max Efficiency, Max Quality, Frequency Regulation, Frequency Conversion and Auto Adaptive, which automatically offers increased efficiency when power conditions are good and enhanced power quality when power conditions are poor.
    Individually Controllable Load Banks Let You Access and Control Outlets Remotely
    Four C17 outlets are split evenly into two switchable load banks, allowing you to reboot select components or shed loads remotely. In addition to those four outlets, this UPS provides two more C17 outlets in their own unswitched bank for powering critical components.
    Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
    The field-replaceable, hot-swappable internal battery provides 16.3of support at half load and 4.7at full load, keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports smart external battery packs, such as Tripp Lite?s BP24V36-2USBoth the internal and external batteries are automatically sensed and configured during replacement to offer accurate runtime-remaining and battery age notifications. The intelligent battery management system with temperature-compensated charging extends battery life.
    Automatic Bypass Maintains Utility Output During Fault Conditions
    Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions.
    ENERGY STAR-Certified Economy Mode Helps You Save Money and Protect the Environment
    By meeting strict EPA efficiency guidelines, this ENERGY STAR-certified UPS system helps you save money and energy. A power-saving Economy mode setting option offers enhanced efficiency and reduced BTU output when utility power is already high quality.
    Automatically Turns Back On After Power Is Restored
    Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement.
    Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
    The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status.
    Advanced Communications Ports Allow for Automatic Saves and Shutdowns
    RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite’s free downloadable PowerAlert software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.
    Optional WEBCARDLX Network Interface Offers 24/7 Remote Access for Monitoring and Control
    The optional WEBCARDLXwith the latest version of PowerAlert Device Manager firmware provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. Auto Probe allows a UPS with switched loads to automatically reboot devices if a network communication failure is detected.
    Versatile Installation Options
    Hardware is included for mounting the UPS system in 2U of space in an EIA-standard 19-inch 4-post rack. Use the optional 2POSTRMKITWMfor 2-post rack mounting or the optional 2-9USTANDfor mounting in an upright tower position. The C16 power inlet accepts a variety of user-supplied input cords.
  • Technical Data

     

    OVERVIEW
    UPC Code037332185648
    UPS TypeOn-Line
    INPUT
    Rated input current (Maximum Load)4.99A
    Nominal Input Voltage(s) Supported200V AC; 208V AC; 220V AC; 230V AC; 240V AC
    UPS Input Connection TypeC14 inlet
    Input PhaseSingle-Phase
    OUTPUT
    Output Volt Amp Capacity (VA)1000
    Output Capacity (kVA)1
    Output Watt Capacity (Watts)900
    Output kW Capacity (kW)0.9
    Output Capacity DetailsDE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 630 watts for 208/220/230/240V output voltages; Max output is 720W (504W in Frequency Conversion mode) at 200V output voltage

    OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).

    Power Factor  0,9
    Crest Factor  3:1
    Nominal Voltage DetailsNominal output voltage is user configured on first power-on
    Frequency Compatibility50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
    Frequency Compatibility DetailsOutput frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation
    Output Voltage Regulation (Line Mode)+/- 2%
    Output Voltage Regulation (Economy Line Mode)+/- 10%
    Output Voltage Regulation (Battery Mode)+/- 2%
    Included Output Power CablesIncludes 2 C13 to C14 power cables
    Load Management Receptacles  Two switchable 2-outlet load banks
    Output AC Waveform (AC Mode)Pure Sine wave
    Output AC Waveform (Battery Mode)Pure Sine wave
    Nominal Output Voltage(s) Supported200V; 208V; 220V; 230V; 240V
    Output Receptacles(6) C13
    Individually Controllable Load Banks  Yes
    BATTERY
    Battery TypeValve Regulated Lead Acid (VRLA)
    Full Load Runtime (min.)  4.7 min. (900w)
    Half Load Runtime (min.)  12.3 min. (450w)
    Expandable Battery RuntimeSupports extended runtime with optional external battery packs
    Expandable RuntimeYes
    External Battery Pack Compatibility   BP24V15RT2U  (limit 1);  BP24V28-2U  (limit 1);  BP24V36-2US  (multi-pack compatible);  BP24V70-3U  (multi-pack compatible)
    DC System Voltage (VDC)24
    Battery Recharge Rate (Included Batteries)Less than 4.1 hours from 10% to 90% (typical, full load discharge)
    Battery AccessFront panel battery access door
    Internal UPS Replacement Battery Cartridge RBC24S
    Battery Replacement DescriptionHot-swappable, replaceable batteries
    VOLTAGE REGULATION
    Voltage Regulation DescriptionOnline, double-conversion power conditioning
    Overvoltage Correction  2% output voltage regulation during overvoltages to 288V
    Undervoltage Correction  2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)
    USER INTERFACE, ALERTS & CONTROLS
    Front Panel LCD DisplayInteractive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options
    Switches5 front panel switches: On/Off, Up, Down and Escape
    Alarm Cancel OperationPower-fail alarm can be silenced by following on-screen prompts
    Audible AlarmAudible alarm indicates power failure, low battery, overload and fault
    LED Indicators4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)
    SURGE / NOISE SUPPRESSION
    UPS Dataline Suppression DetailsSingle line dialup / network dataline protection included
    EMI / RFI AC Noise Suppression  Yes
    AC Suppression Joule Rating  627
    AC Suppression Response Time  Instantaneous
    PHYSICAL
    Primary Form FactorRackmount
    Cooling MethodFan
    Included Mounting Accessory DescriptionIncluded 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
    Installation Form Factors Supported with Included Accessories4 post 19 inch rackmount
    Installation Form Factors Supported with Optional Accessories2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
    Minimum Required Rack Depth with External Battery Pack (cm)48
    Minimum Required Rack Depth with External Battery Pack (in.)18.75
    Minimum Required Rack Depth without External Battery Pack (cm)46
    Minimum Required Rack Depth without External Battery Pack (in.)18
    Optional Mounting Accessory NotesOptional  2-9USTAND  enables upright tower UPS placement;  2POSTRMKITWM  enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT  enables installation in 2 or 4-post racks using front vertical rails only, without rear support
    Primary UPS Depth (mm)397
    Primary UPS Height (mm)88
    Primary UPS Width (mm)438
    Rack Height2U
    Shipping Dimensions (hwd / cm)24.38 x 50.29 x 59.69
    Shipping Weight (kg)19.96
    UPS Housing MaterialMetal
    UPS Power Module Dimensions (hwd, cm)8.79 x 43.79 x 39.70
    UPS Power Module Weight (kg)12.70
    ENVIRONMENTAL
    Operating Temperature Range+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
    Storage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
    Relative Humidity5 to 95%, non-condensing
    AC Mode BTU / Hr. (Full Load)  245
    AC Economy Mode BTU / Hr. (Full Load)128
    Battery Mode BTU / Hr. (Full Load)  500
    AC Mode Efficiency Rating (100% Load)>93%
    AC Economy Mode Efficiency Rating (100% Load)>96%
    Audible Noise<45dB at front side 1M
    Operating Elevation (m)Up to 3000m
    COMMUNICATIONS
    Network Management Cards WEBCARDLX
    PowerAlert SoftwareAvailable for download at www.tripplite.com
    Communications CableUSB and DB9 cabling included
    WatchDog CompatibilitySupports Watchdog application, OS and hard-reboot restart options for remote applications
    Network Management Card DescriptionNetwork management card optional
    Communications InterfaceContact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
    LINE / BATTERY TRANSFER
    Transfer Time  No transfer time (0 ms.) in online, double-conversion mode; 3-9 ms. transfer time during economy mode operation
    Low Voltage Transfer to Battery Power (Setpoint)160V (100% load), 140V (66% load), 120V (33% load)
    High Voltage Transfer to Battery Power (Setpoint)288V
    FEATURES & SPECIFICATIONS
    Grounding LugBack panel grounding lug included
    Cold Start (Startup in Battery Mode During a Power Failure)Cold-start operation supported
    High Availability UPS Features  Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic inverter bypass; Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time
    Green Energy-Saving FeaturesHigh efficiency economy mode operation; Individually controllable load banks
    STANDARDS & COMPLIANCE
    UPS CertificationsCE; ENERGY STAR Qualified; Tested to CSA (Canada); Tested to EAC (Belarus, Kazakhstan, Russia); Tested to NOM (Mexico); Tested to SASO (Saudi Arabia); Tested to UL1778 (USA)
    Certification DetailsSeries Number(s) AGPS8294; Agency Standard Tested IEC62040-1:2008+A1; US Approvals UL1778 5TH; Canadian Approvals YES. CSA C22.2 NO.107.3-14; CE Approvals YES; EMI Approvals EN62040-2 (CAT C2) FCC A)
    WARRANTY
    Product Warranty Period (Worldwide)2-year limited warranty
    Connected Equipment Insurance (U.S., Canada & Puerto Rico)$250,000 Ultimate Lifetime Insurance 
  • Onsite Maintenance

    Onsite Maintenance is as easy as 1, 2, 3, 4. Contact us for further information 24×7 on our sales number.

    1: Plug and Play (400-3kVA) – Extended Warranty Contracts from 1 to 5 years from £5.99 per month ex VAT

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your warranty up to 3 years, next working day replacementGreen tick
    Warranty Plus Extends your warranty up to 5 years, next working day replacementGreen tick
    Intervention, Provides one preventative maintenance visit, planned visitGreen tick
    Battery Plus, Provides replacement batteries to site, next working day replacementGreen tick
    Warranty One Extends your warranty up to 1 year, next working day replacementGreen tick

    2: Hardwired (4kVA Upwards– Onsite Maintenance Contracts from 1 to 5 years from £49.99 per month ex VAT

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 1kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

     

    Technical Hotline 24/7YesYesYesGreen tick
    Preventative MaintenanceYesYesYesGreen tick
    Remote Monitoring 24/7YesYesYesGreen tick
    Firmware UpgradesYesYesYesGreen tick
    Emergency ResponseYesYesYesGreen tick
    LabourYesYesYesGreen tick
    PartsYesYesYesGreen tick
    Monthly Event/Status ReportoptionoptionoptionGreen tick
    Onsite Crash KitoptionoptionoptionGreen tick
    Response Time12 working hours8 working hours4 clock hoursGreen tick

    3: 24×7 Remote Monitoring Contracts from 1 month to 5 years from £29.99 per month ex VAT

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hoursGreen tick
    24×7 flexible status and remote monitoring.Green tick
    Encrypted communication, allowing safe offsite monitoringGreen tick
    Alarms and events emailed and SMS texted automaticallyGreen tick
    Firewall FriendlyGreen tick
    Cloud based status overview and multiple sites status on one screenGreen tick
    Allows First Fix Response to SiteGreen tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.