SKU: SUINT3000LCD2U Category: Brand: Tripp Lite Tag:

Tripp Lite 208/230V 3000VA 2.7kW Double-Conversion UPS - 10 Outlets, Extended Run, Card Slot, LCD, USB, DB9, 2U - SUINT3000LCD2U

  • ✔ Trusted UK Supplier
  • ✔ Fast UK Delivery Available
  • ✔ Manufacturer Warranty Included
  • ✔ Expert Advice Available
  • ✔ Protects equipment from power loss
  • ✔ Prevents downtime and data loss
  • ✔ Suitable for business and home setups

    Tailor to your needs. Speak to a Specialist.
    Call: 0800 978 8988

    Out of stock

    Need a quote?

    Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss
    This 200/208/220/230/240V 50/60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in online and battery modes. Featuring a 2700W capacity, high 0.9 power factor, 570 joules of surge suppression, true online operation with pure sine wave output and zero transfer time to battery mode in online double-conversion mode, the SmartOnline? SUINT3000LCD2U double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closets, computer rooms and data centre equipment.

    Set Power Strategies to Reflect Your Protection Priorities
    Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from five selectable strategies: Max Efficiency, Max Quality, Frequency Regulation, Frequency Conversion and Auto Adaptive, which automatically offers increased efficiency when power conditions are good and enhanced power quality when power conditions are poor.

    Individually Controllable Load Banks Let You Access and Control Outlets Remotely
    Six C17 and two C19 outlets are split evenly into two switchable load banks, allowing you to reboot select components or shed loads remotely. In addition to those eight outlets, this UPS provides two more C17 outlets in their own unswitched bank for powering critical components.

    Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
    The field-replaceable, hot-swappable internal battery provides 17.5of support at half load;”>1750W) and five at full load;”>2700W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports ‘smart’ external battery packs, such as Tripp Lite’s BP72V18-2USBoth the internal and external batteries are automatically sensed and configured during replacement to offer accurate runtime-remaining and battery age notifications during outages. The intelligent battery management system with temperature-compensated charging extends battery life.

    Automatic Bypass Maintains Utility Output During Fault Conditions
    Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions.

    ENERGY STAR-Certified Economy Mode Helps You Save Money and Protect the Environment
    By meeting strict EPA efficiency guidelines, this ENERGY STAR-certified UPS system helps you save money and energy. A power-saving Economy mode setting option offers enhanced efficiency and reduced BTU output when utility power is already high quality.

    Automatically Turns Back On After Power Is Restored
    Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement.

    Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
    The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status.

    Advanced Communications Ports Allow for Automatic Saves and Shutdowns
    RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite’s free downloadable PowerAlert? software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.

    Optional WEBCARDLX Network Interface Offers 24/7 Access
    The optional WEBCARDLXwith the latest version of PowerAlert Device Manager firmware provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. Auto Probe allows a UPS with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.

    Versatile Installation Options
    Hardware is included for mounting the UPS system in 2U of space in an EIA-standard 19-inch 4-post rack. Use the optional 2POSTRMKITWMfor 2-post rack mounting or the optional 2-9USTANDfor mounting in an upright tower position. The C20 power inlet accepts a variety of user-supplied input cords.

     

    OVERVIEW
    UPC Code 037332185631
    UPS Type On-Line
    INPUT
    Rated input current (Maximum Load) 14.97A
    Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
    UPS Input Connection Type C20 inlet
    Input Phase Single-Phase
    OUTPUT
    Output Volt Amp Capacity (VA) 3000
    Output Capacity (kVA) 3
    Output Watt Capacity (Watts) 2700
    Output kW Capacity (kW) 2.7
    Output Capacity Details DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1890 watts for 208/220/230/240V output voltages; Max output is reduced to 2160W at 200V output voltage in all operating modes

    OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).

    Power Factor   0.9
    Crest Factor   3:1
    Nominal Voltage Details Nominal output voltage is user configured on first power-on
    Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
    Frequency Compatibility Details Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation
    Output Voltage Regulation (Line Mode) +/- 2%
    Output Voltage Regulation (Economy Line Mode) +/- 10%
    Output Voltage Regulation (Battery Mode) +/- 2%
    Included Output Power Cables Includes 2 C13 to C14 and 1 C19 to C20 power cables
    Load Management Receptacles   Two switchable 4 outlet load banks (3 C13 and 1 C19 per bank)
    Output AC Waveform (AC Mode) Pure Sine wave
    Output AC Waveform (Battery Mode) Pure Sine wave
    Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
    Output Receptacles (8) C13; (2) C19
    Individually Controllable Load Banks   Yes
    BATTERY
    Battery Type Valve Regulated Lead Acid (VRLA)
    Full Load Runtime (min.)   5 min. (2700w)
    Half Load Runtime (min.)   13.5 min. (1350w)
    Expandable Battery Runtime Supports extended runtime with optional external battery packs
    Expandable Runtime Yes
    External Battery Pack Compatibility    BP72V15-2U  (limit 1);  BP72V28RT-3U  (multi-pack compatible);  BP72V18-2US  (multi-pack compatible)
    DC System Voltage (VDC) 72
    Battery Recharge Rate (Included Batteries) 3.0 hours from 10% to 90% (typical, full load discharge)
    Battery Access Front panel battery access door
    Internal UPS Replacement Battery Cartridge  RBC72S
    Battery Replacement Description Hot-swappable, replaceable batteries
    VOLTAGE REGULATION
    Voltage Regulation Description Online, double-conversion power conditioning
    Overvoltage Correction   2% output voltage regulation during overvoltages to 288
    Undervoltage Correction   2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)
    USER INTERFACE, ALERTS & CONTROLS
    Front Panel LCD Display Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options
    Switches 5 front panel switches: On/Off, Up, Down and Escape
    Alarm Cancel Operation Power-fail alarm can be silenced by following on-screen prompts
    Audible Alarm Audible alarm indicates power failure, low battery, overload and fault
    LED Indicators 4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)
    SURGE / NOISE SUPPRESSION
    UPS Dataline Suppression Details Single line dialup / network dataline protection included
    EMI / RFI AC Noise Suppression   Yes
    AC Suppression Joule Rating   570
    AC Suppression Response Time   Instantaneous
    PHYSICAL
    Primary Form Factor Rackmount
    Cooling Method Fan
    Included Mounting Accessory Description 4 post installation accessories included
    Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
    Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); Tower ( 2-9USTAND )
    Minimum Required Rack Depth with External Battery Pack (cm) 77
    Minimum Required Rack Depth with External Battery Pack (in.) 30.25
    Minimum Required Rack Depth without External Battery Pack (cm) 70
    Minimum Required Rack Depth without External Battery Pack (in.) 27.75
    Primary UPS Depth (mm) 616
    Primary UPS Height (mm) 88
    Primary UPS Width (mm) 438
    Rack Height 2U
    Shipping Dimensions (hwd / cm) 24.00 x 59.99 x 76.00
    Shipping Weight (kg) 39.01
    UPS Housing Material Metal
    UPS Power Module Dimensions (hwd, cm) 8.79 x 43.79 x 61.60
    UPS Power Module Weight (kg) 31.17
    ENVIRONMENTAL
    Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
    Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
    Relative Humidity 5 to 95%, non-condensing
    AC Mode BTU / Hr. (Full Load)   933
    AC Economy Mode BTU / Hr. (Full Load) 485
    Battery Mode BTU / Hr. (Full Load)   1399
    AC Mode Efficiency Rating (100% Load) >90%
    AC Economy Mode Efficiency Rating (100% Load) >95%
    Audible Noise <50dB at front side 1M
    Operating Elevation (m) Up to 3000m
    COMMUNICATIONS
    Network Management Cards  SNMPWEBCARD ;  WEBCARDLX
    PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert
    Communications Cable USB and DB9 cabling included
    WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
    Network Management Card Description Network management card optional
    Communications Interface Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
    LINE / BATTERY TRANSFER
    Transfer Time   No transfer time (0 ms.) in online, double-conversion mode; 4 ms. transfer time during economy mode operation
    Low Voltage Transfer to Battery Power (Setpoint) 160V (100% load), 140V (66% load), 120V (33% load)
    High Voltage Transfer to Battery Power (Setpoint) 288V
    FEATURES & SPECIFICATIONS
    Grounding Lug Back panel grounding lug included
    Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
    High Availability UPS Features   Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic inverter bypass; Expandable battery backup; Hot swappable batteries; On-Line/Double-Conversion; Remote management; Sine wave output; Surge/noise protection; Zero transfer time
    Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks
    STANDARDS & COMPLIANCE
    UPS Certifications CE; ENERGY STAR Qualified; Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to EAC (Belarus, Kazakhstan, Russia); Tested to SASO (Saudi Arabia); Tested to UL1778 (USA)
    Certification Details Meets EMI approvals IEC62040-2:2006; FCC Part 15
    WARRANTY
    Product Warranty Period (Worldwide) 2-year limited warranty
    Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance 

    Nationwide Onsite Maintenance is as easy as saying Bronze, Silver, Gold, Platinum.

    1: Plug and Play (400VA-3kVA) – Extended Warranty Contracts and Maintenance contracts

    For plug & play UPS Critical Power offers you a full range of distributed service packs. These competitively priced turn-key solutions optimize your UPS performances and enhance the availability of your equipment while meeting your financial constraints and technical requirements.

    Warranty Plus Extends your standard warranty up to 6 years, next working day replacement* with labour or without. Green tick
    Intervention, Provides one preventative maintenance visit, planned visit inside our outside hours. Green tick
    Battery Plus, Provides replacement batteries to site, next working day replacement or same day Green tick

    2: Hardwired (4kVA Upwards including Three Phase UPS) – Maintenance Contracts

    No matter what, your UPS, Generator, Cooling, Switchgear or Electrical Hardware must be ready to perform at all times. While every power solution we supply is backed-up by a comprehensive warranty with the manufacturer, maintenance plans to ensure business continuity are highly recommended, particularly for UPS systems from 4kVA. In particular, the battery set is of prime importance, and must be in good working order. With other consumables, such as fans and DC capacitors requiring regular maintenance and inspection logs reviewed to predict potential future problems.

    Services Included

    Silver Level

    Gold Level

    Platinum Level

    Platinum Plus

     

    Technical Hotline 24/7 Yes Yes Yes Yes Green tick
    Preventative Maintenance Yes Yes Yes Yes Green tick
    Remote Monitoring 24/7 Yes Yes Yes Yes Green tick
    Firmware Upgrades Yes Yes Yes Yes Green tick
    Emergency Response Yes Yes Yes Yes Green tick
    Labour Yes Yes Yes Yes Green tick
    Parts Yes Yes Yes option Green tick
    Monthly Event/Status Report option option option option Green tick
    Onsite Crash Kit option option option onsite Green tick
    Response Time 12 working hours 8 working hours 4 clock hours 4 clock hours Green tick
    Guaranteed Fix time – – – 4 Clock hours Green tick

    3: 24×7 Remote Monitoring Contracts –

    Remote monitoring of UPS, Generators, Air Conditioning, Site Access and Environmental Systems is essential to allow swift offsite investigation of fault reports and real-time monitoring of the site status, allowing the correct response to be created and dispatched to site.

    Engineer Installation and configuration during normal hours Green tick
    24×7 flexible status and remote monitoring. Green tick
    Encrypted communication, allowing safe offsite monitoring Green tick
    Alarms and events emailed and SMS texted automatically Green tick
    Firewall Friendly Green tick
    Cloud based status overview and multiple sites status on one screen Green tick
    Allows First Fix Response to Site Green tick

    4. IR Thermal Imaging Surveys – Infrared electrical inspection. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components. – Contact us for more information.

    Detect system overloads, loose defective components and damaged switchgear. Infrared electrical testing finds hot, dangerous problems quickly. Infrared electrical inspections find hot spots caused by defects in connections and components.

    Infrared thermography is used to find areas of excess heat (caused by increased resistance) so that problems can be corrected before a component fails, causing damage to the component, creating safety hazards and productivity loss. Because increased heating is a sign of failure, infrared is the best diagnostic tool available for finding these hot connections in the early stages of degeneration.

    5. Switchgear – Contact us for more information.

    Switchgear maintenance is essential for efficient save plant operation and prolonged life span in the field Switchgear should be maintained as follows.

    • Live Maintenance – Unintrusive and consists of taking metering values, carrying out visual inspections and a thermal imaging survey of the switchboard. This is recommended to be carried out yearly.
    • Breaker Maintenance – Switchboard would need to be Isolated and all ACB’s and MCCB’s are maintained including visual and mechanical checks, greasing and secondary injection testing of the trip units. This is recommended to be carried out every 2 years.
    • Full Isolated Maintenance – Switchboard would need to be fully isolated from upstream supplies (HV). Breakers are maintained as per the above but also full maintenance carried out of the Switchboard to clean all compartments and carry out tightness checking of busbars and terminations etc. This is recommended to be carried out every 4 years.